Literature DB >> 22387126

Characterisation of partial volume effect and region-based correction in small animal positron emission tomography (PET) of the rat brain.

Wencke Lehnert1, Marie-Claude Gregoire, Anthonin Reilhac, Steven R Meikle.   

Abstract

Accurate quantification of PET imaging data is required for a useful interpretation of the measured radioactive tracer concentrations. The partial volume effect (PVE) describes signal dilution and mixing due to spatial resolution and sampling limitations, which introduces bias in quantitative results. In the present study we investigated the magnitude of PVE for volumes of interest (VOIs) in the rat brain and the effect of positron range. In simulated (11)C-raclopride studies we examined the influence of PVE on time activity curves in striatal and cerebellar VOIs and binding potential estimation. The performance of partial volume correction (PVC) was studied using the region-based geometric transfer matrix (GTM) method including the question of whether a spatially variant point spread function (PSF) is necessary for PVC of a rat brain close to the centre of the field of view. Furthermore, we determined the effect of spillover from activity outside the brain. The results confirmed that PVE is significant in rat brain PET and showed that positron range is an important factor that needs to be included in the PSF. There was considerable bias in time activity curves for the simulated (11)C-raclopride studies and significant underestimation of binding potential even for very small centred VOIs. Good activity recovery was achieved with the GTM PVC using a spatially invariant simulated PSF when no activity was present outside the brain. PVC using a simple Gaussian fit point spread function was not sufficiently accurate. Spillover from regions outside the brain had a significant impact on measured activity concentrations and reduced the accuracy of PVC with the GTM method using rat brain regions alone, except for the smallest VOI size but at the cost of increased noise. Voxel-based partial volume correction methods which inherently compensate for spillover from outside the brain might be a more suitable choice.
Copyright © 2012 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22387126     DOI: 10.1016/j.neuroimage.2012.02.032

Source DB:  PubMed          Journal:  Neuroimage        ISSN: 1053-8119            Impact factor:   6.556


  13 in total

Review 1.  Advances in PET Detection of the Antitumor T Cell Response.

Authors:  M N McCracken; R Tavaré; O N Witte; A M Wu
Journal:  Adv Immunol       Date:  2016-04-05       Impact factor: 3.543

2.  Influence of the partial volume correction method on (18)F-fluorodeoxyglucose brain kinetic modelling from dynamic PET images reconstructed with resolution model based OSEM.

Authors:  Spencer L Bowen; Larry G Byars; Christian J Michel; Daniel B Chonde; Ciprian Catana
Journal:  Phys Med Biol       Date:  2013-09-20       Impact factor: 3.609

3.  Influence of Co-57 and CT Transmission Measurements on the Quantification Accuracy and Partial Volume Effect of a Small Animal PET Scanner.

Authors:  Julia G Mannheim; Andreas M Schmid; Bernd J Pichler
Journal:  Mol Imaging Biol       Date:  2017-12       Impact factor: 3.488

4.  Regional Differences in Cerebral Glucose Metabolism After Cardiac Arrest and Resuscitation in Rats Using [18F]FDG Positron Emission Tomography and Autoradiography.

Authors:  Alessandro Putzu; Silvia Valtorta; Giuseppe Di Grigoli; Matthias Haenggi; Sara Belloli; Antonio Malgaroli; Marco Gemma; Giovanni Landoni; Luigi Beretta; Rosa Maria Moresco
Journal:  Neurocrit Care       Date:  2018-06       Impact factor: 3.210

5.  Immune Activation in Pregnant Rats Affects Brain Glucose Consumption, Anxiety-like Behaviour and Recognition Memory in their Male Offspring.

Authors:  Cyprien G J Guerrin; Alexandre Shoji; Janine Doorduin; Erik F J de Vries
Journal:  Mol Imaging Biol       Date:  2022-04-05       Impact factor: 3.484

6.  Prediction of standard-dose brain PET image by using MRI and low-dose brain [18F]FDG PET images.

Authors:  Jiayin Kang; Yaozong Gao; Feng Shi; David S Lalush; Weili Lin; Dinggang Shen
Journal:  Med Phys       Date:  2015-09       Impact factor: 4.071

7.  Imaging of brain TSPO expression in a mouse model of amyotrophic lateral sclerosis with (18)F-DPA-714 and micro-PET/CT.

Authors:  S Gargiulo; S Anzilotti; A R D Coda; M Gramanzini; A Greco; M Panico; A Vinciguerra; A Zannetti; C Vicidomini; F Dollé; G Pignataro; M Quarantelli; L Annunziato; A Brunetti; M Salvatore; S Pappatà
Journal:  Eur J Nucl Med Mol Imaging       Date:  2016-01-27       Impact factor: 9.236

8.  A depth-encoding PET detector for high resolution PET using 1 mm SiPMs.

Authors:  Junwei Du; Xiaowei Bai; Simon R Cherry
Journal:  Phys Med Biol       Date:  2020-08-19       Impact factor: 3.609

9.  Region-Based Partial Volume Correction Techniques for PET Imaging: Sinogram Implementation and Robustness.

Authors:  Mike Sattarivand; Jennifer Armstrong; Gregory M Szilagyi; Maggie Kusano; Ian Poon; Curtis Caldwell
Journal:  Int J Mol Imaging       Date:  2013-12-17

10.  Longitudinal Characterization of [18F]-FDG and [18F]-AV45 Uptake in the Double Transgenic TASTPM Mouse Model.

Authors:  Ann-Marie Waldron; Leonie Wyffels; Jeroen Verhaeghe; Jill C Richardson; Mark Schmidt; Sigrid Stroobants; Xavier Langlois; Steven Staelens
Journal:  J Alzheimers Dis       Date:  2017       Impact factor: 4.472

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.