| Literature DB >> 32410914 |
Ping Li1, Fang Fang1, Xu Qiu1, Nan Xu1, Yan Wang1, Wen-Bin Ouyang1, Feng-Wen Zhang1, Hai-Bo Hu1, Xiang-Bin Pan1,2.
Abstract
BACKGROUND: To evaluate the feasibility of using a single device to close multiple atrial septal defects (ASDs) under the guidance of transthoracic echocardiography (TTE) and with the aid of three-dimensional (3D) printing models.Entities:
Mesh:
Year: 2020 PMID: 32410914 PMCID: PMC7201835 DOI: 10.1155/2020/1751025
Source DB: PubMed Journal: J Interv Cardiol ISSN: 0896-4327 Impact factor: 2.279
Figure 1Three-dimensional printing working flow. Simple working flowchart in patients with multiple ASDs, from image acquisition to three-dimensional (3D) printed solid and hollow model.
Figure 23D printed model of a patient with multiple ASDs. (a) and (b) show the model viewed from left and right atrial sides, respectively. The arrows depict the position of the multiple ASDs. (c) and (d) illustrate the status after occluder deployment in the 3D printing model.
Figure 3Percutaneous closure of multiple ASDs under TTE guidance. (a) Multiple ASDs image as displayed in subcostal view. (b) The left disc was released (parasternal short-axis view). (c) The ASDs were closed (four-chamber view).
Patients' data.
| 3D printing and TTE group ( | Conventional group ( |
| |
|---|---|---|---|
| Female | 17 (65.4%) | 15 (55.6%) | 0.858 |
|
| |||
| Age (years) | 18.8 ± 15.9 | 14.0 ± 11.6 | 0.217 |
|
| |||
| Three defects | 6 (23.1%) | 4 (14.8%) | 0.452 |
|
| |||
| Maximum distance (mm) defect | 8.0 ± 3.9 | 7.6 ± 3.0 | 0.673 |
|
| |||
| Large defect distance (defined as ≥ 7 mm) | 14 (53.8%) | 11 (40.7%) | 0.349 |
|
| |||
| PFO occluder | 4 (15.4%) | 3 (11.1%) | 0.646 |
|
| |||
| Occluder replacement | 1 (3.8%) | 16 (59.3%) | <0.0001 |
| Once | 1 (3.8%) | 8 (29.6%) | |
| Twice | 4 (14.8%) | ||
| Thrice | 4 (14.8%) | ||
|
| |||
| Occluder size, empirical estimation (mm) | 18.0 ± 6.0 | — | |
| Occluder size, 3D model estimation (mm) | 26.0 ± 6.0 | — | |
|
| |||
| Occluder size for patients (mm) | 26.0 ± 6.0 | 23.5 ± 5.4 | 0.968 |
|
| |||
| Intraoperative residual shunt | 5 (19.2%) | 12 (44.4%) | 0.048 |
|
| |||
| Residual shunt at 6 months after procedure | 2 (7.7%) | 8 (29.6%) | 0.042 |
|
| |||
| Cost (CNY) | 32960.8 ± 2018.7 | 41019.9 ± 13758.2 | 0.0047 |
Values are expressed as means ± SD, n (%). p=0.0007 vs occluder size on 3D model.
Figure 4Bland–Altman plot analysis. Bland–Altman plot of empirical estimation versus 3D printed model estimation of occluder size.