Literature DB >> 14755820

Transcatheter closure of double atrial septal defects with a single Amplatzer device.

Malgorzata Szkutnik1, Jozef Masura, Jacek Bialkowski, Pavol Gavora, Pawel Banaszak, Jacek Kusa, Marian Zembala.   

Abstract

Transcatheter closure of single secundum atrial defects has become the standard of treatment. The purpose of our study was to analyze the results of using a single Amplatzer device for closure of double atrial septal defects. Such defects were diagnosed in 41 out of 363 patients with atrial septal defects (ASDs) closed by transcatheter method. In 39, a single Amplatzer device was used. The size of the larger defect ranged from 5 to 18 mm, the smaller defect from 2 to 7 mm, with the distance between the borders of the communications ranging from 2 to 12 mm. We performed sizing and closure of only the larger defect. The mean size of implanted devices was 16.5 +/- 5.5 mm, equal to the stretched diameter of the main defect or 1-4 mm larger. The closure rate assessed by color Doppler flow examination was 61% after 24 hr, 78% after 1 month, 83% after 3 months, 86% after 1 year, and 95% after 2 years. If the distance between the two defects exceeded 7 mm, residual leaks were observed but tended to decrease and disappear with time. Selected patients with double atrial septal defects can be effectively treated with implantation of a single Amplatzer device. Copyright 2004 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 14755820     DOI: 10.1002/ccd.10753

Source DB:  PubMed          Journal:  Catheter Cardiovasc Interv        ISSN: 1522-1946            Impact factor:   2.692


  10 in total

1.  Simultaneous release of interdigitating atrial septal defect and patent foramen ovale Amplatzer devices.

Authors:  William Keeble; Dylan A Taylor
Journal:  Can J Cardiol       Date:  2008-01       Impact factor: 5.223

2.  Clinical advantage of real-time three-dimensional transesophageal echocardiography for transcatheter closure of multiple atrial septal defects.

Authors:  Manabu Taniguchi; Teiji Akagi; Yasufumi Kijima; Shunji Sano
Journal:  Int J Cardiovasc Imaging       Date:  2013-04-23       Impact factor: 2.357

3.  Transcatheter closure of multiple secundum atrial septal defects using multiple occluder devices: A comparative experience between pediatric and adult patients.

Authors:  Pramod Sagar; Kothandam Sivakumar; Ramyashri Chandrasekaran; Sreeja Pavithran; Puthiyedath Thejaswi; Rajendran Monica
Journal:  Ann Pediatr Cardiol       Date:  2022-08-19

4.  Intracardiac Echocardiogram: Feasibility, Efficacy, and Safety for Guidance of Transcatheter Multiple Atrial Septal Defects Closure.

Authors:  Jae-Hee Seol; Ah-Young Kim; Se-Yong Jung; Jae-Young Choi; Yeon-Jae Park; Jo-Won Jung
Journal:  J Clin Med       Date:  2022-04-24       Impact factor: 4.964

5.  Cribriform amplatzer device closure of fenestrated atrial septal defects: feasibility and technical aspects.

Authors:  Mohammed Numan; Amal El Sisi; Magdi Tofeig; Salwa Gendi; Tohami Tohami; Howaida G El-Said
Journal:  Pediatr Cardiol       Date:  2007-11-13       Impact factor: 1.655

Review 6.  Transcatheter closure of atrial septal defect: principles and available devices.

Authors:  Se Yong Jung; Jae Young Choi
Journal:  J Thorac Dis       Date:  2018-09       Impact factor: 2.895

7.  Use of cribriform amplatzer septal occluder in the pediatric population: Feasibility, safety, and technical considerations.

Authors:  Priya Pradhan; Sneha Jain; Supratim Sen; Bharat Dalvi
Journal:  Ann Pediatr Cardiol       Date:  2021-04-10

8.  Fenestrated atrial septal defect percutaneously occluded by a single device: procedural and financial considerations.

Authors:  Roie Tal; Qarawani Dahud; Avraham Lorber
Journal:  Cardiol Ther       Date:  2012-11-27

Review 9.  Role of Echocardiography in the Diagnosis and Interventional Management of Atrial Septal Defects.

Authors:  P Syamasundar Rao
Journal:  Diagnostics (Basel)       Date:  2022-06-18

10.  Personalized Three-Dimensional Printing and Echoguided Procedure Facilitate Single Device Closure for Multiple Atrial Septal Defects.

Authors:  Ping Li; Fang Fang; Xu Qiu; Nan Xu; Yan Wang; Wen-Bin Ouyang; Feng-Wen Zhang; Hai-Bo Hu; Xiang-Bin Pan
Journal:  J Interv Cardiol       Date:  2020-04-25       Impact factor: 2.279

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.