Literature DB >> 26028664

Comparison of the effectiveness and safety of single versus dual occluders for the closure of multiple atrial septal defects.

Zhi Hu1, Yushun Zhang, Tingting Zhang, Gesheng Cheng, Xuegang Xie, Xumei He, Yajuan Du.   

Abstract

BACKGROUND: The purpose of this study was to compare the effectiveness and safety of a single vs dual occluders in the treatment of multiple atrial septal defects (ASDs).
METHODS: We retrospectively reviewed the records of patients with multiple ASDs treated with single or dual Amplatzer septal occluders from January 2010 to March 2013. Data extracted from the medical records included patient demographic information, ASD sizes, distance between the defects, preprocedure and postprocedure echocardiographic parameters, and treatment-related complications. Treatment success was defined as the occluder stably fixed without shunting, and no effects to other heart structures.
RESULTS: Sixty-four patients were included. There were no significant differences between the two groups with respect to age, weight, gender, larger ASD diameter, smaller ASD diameter, and echocardiographic parameters before treatment. Successful closure was achieved in all patients in the single-occluder group regardless of whether the distance between defects was ≥7 mm or <7 mm, and in all patients in the dual-occluder group. Residual shunting after surgery and residual leakage after 1-year follow-up were significantly more common in the dual-occluder group compared with the single-occluder group (residual shunting: 31% vs. 8%, respectively; P=.02 and residual leakage: 19% vs. 2%, respectively; P=.04). No procedure-related complications occurred in either group.
CONCLUSIONS: Single and dual occluders are both safe and effective for the repair of multiple ASDs; however, the risk of residual shunt is greater with dual occluders.

Entities:  

Mesh:

Year:  2015        PMID: 26028664

Source DB:  PubMed          Journal:  J Invasive Cardiol        ISSN: 1042-3931            Impact factor:   2.022


  3 in total

1.  Transcatheter closure of multiple secundum atrial septal defects using multiple occluder devices: A comparative experience between pediatric and adult patients.

Authors:  Pramod Sagar; Kothandam Sivakumar; Ramyashri Chandrasekaran; Sreeja Pavithran; Puthiyedath Thejaswi; Rajendran Monica
Journal:  Ann Pediatr Cardiol       Date:  2022-08-19

2.  Short-term outcomes of transcatheter closure of secundum atrial septal defect in children and adolescents: An experience of two centers in Upper Egypt.

Authors:  Safaa H Ali; Amal El Sisi; Duaa M Raafat; Salah-Eldin Amry; Sharaf E D Mahamoud
Journal:  J Saudi Heart Assoc       Date:  2017-05-10

3.  Personalized Three-Dimensional Printing and Echoguided Procedure Facilitate Single Device Closure for Multiple Atrial Septal Defects.

Authors:  Ping Li; Fang Fang; Xu Qiu; Nan Xu; Yan Wang; Wen-Bin Ouyang; Feng-Wen Zhang; Hai-Bo Hu; Xiang-Bin Pan
Journal:  J Interv Cardiol       Date:  2020-04-25       Impact factor: 2.279

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.