Literature DB >> 18412085

A new device to close secundum atrial septal defects: first clinical use to close multiple defects in a child.

Ali Halabi1, Ziyad M Hijazi.   

Abstract

Transcatheter device closure of secundum atrial septal defects (ASD) has become an accepted treatment modality. Currently, the only device that can be used for large defects is the Amplatzer Septal Occluder. We report on a new device (Occlutech Figulla), to close multiple ASDs in a child with two large defects using 12 and 15 mm devices. 2008 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2008        PMID: 18412085     DOI: 10.1002/ccd.21451

Source DB:  PubMed          Journal:  Catheter Cardiovasc Interv        ISSN: 1522-1946            Impact factor:   2.692


  8 in total

1.  Comparison of the Occlutech ® Figulla ® septal occluder and Amplatzer ® septal occluder for atrial septal defect device closure.

Authors:  Supaporn Roymanee; Worakan Promphan; Nakharin Tonklang; Kanjarut Wongwaitaweewong
Journal:  Pediatr Cardiol       Date:  2015-01-30       Impact factor: 1.655

2.  Multiple transcatheter interventions in the same session in congenital cardiopathies.

Authors:  Saritas Turkay; Erdem Abdullah; Akdeniz Celal; Zeybek Cenap; Erol Nurdan; Demir Fadli; Demir Halil; Aydemir Numan Ali; Celebi Ahmet
Journal:  J Cardiovasc Dis Res       Date:  2010-10

3.  Transcatheter atrial septal defect closure using occlutech figulla device: a two-center experience.

Authors:  Hojat Mortezaeian; Keyhan Sayadpour Zanjani; Elaheh Malakan Rad
Journal:  J Tehran Heart Cent       Date:  2013-10-28

4.  Feasibility of percutaneous closure of atrial septal defects in adults under transthoracic echocardiography guidance using the Figulla atrial septal defect occluder device.

Authors:  Mahmoud Ali; Hesham Salah El-Din; Sameh Bakhoum; Amal El-Sisi; Kareem Mahmood; Heba Farouk; Hossam Kandil
Journal:  J Saudi Heart Assoc       Date:  2017-04-21

5.  Transcatheter closure of atrial septal defect in a patient with cor triatriatum sinister and atrial septal defect.

Authors:  Wasana Hongkan; Kriangsak Thongchaiprasit; Kritvikrom Durongpisitkul
Journal:  Case Rep Cardiol       Date:  2011-08-01

6.  Successful retrieval of a Figulla Occlutech septal occluder - embolized device stability and potential solutions.

Authors:  Masood Sadiq; Asif Ur Rehman; Amjad Mehmood
Journal:  Ann Pediatr Cardiol       Date:  2016 May-Aug

7.  Personalized Three-Dimensional Printing and Echoguided Procedure Facilitate Single Device Closure for Multiple Atrial Septal Defects.

Authors:  Ping Li; Fang Fang; Xu Qiu; Nan Xu; Yan Wang; Wen-Bin Ouyang; Feng-Wen Zhang; Hai-Bo Hu; Xiang-Bin Pan
Journal:  J Interv Cardiol       Date:  2020-04-25       Impact factor: 2.279

8.  Safety of Occlutech Septal Occluder ACCELL Flex II for Transcatheter Closure of Secundum Atrial Septal Defects in Children: A Long-Term Follow-Up.

Authors:  Amal M El-Sisi; Sonia A El-Saiedi; Rasha Ammar; Asmaa Abdelhameed; Ziyad M Hijazi; Mohammed M Soliman
Journal:  J Interv Cardiol       Date:  2022-01-04       Impact factor: 2.279

  8 in total