| Literature DB >> 32321425 |
Arpa Chutipongtanate1, Churairat Yasaeng1, Tanit Virankabutra1, Somchai Chutipongtanate2,3.
Abstract
BACKGROUND: Transfusion decision during the perioperative period mostly relies on the point-of-care testing for Hb measurement. This study aimed systematically compared four point-of-care methods with the central laboratory measurement of hemoglobin (LHb) regarding the accuracy, precision, and assay practicality to identify the preferred point-of-care method during the perioperative period.Entities:
Keywords: Agreement; Bias; Correlation; Hemoglobin measurement; Point-of-care testing
Mesh:
Substances:
Year: 2020 PMID: 32321425 PMCID: PMC7175548 DOI: 10.1186/s12871-020-01008-8
Source DB: PubMed Journal: BMC Anesthesiol ISSN: 1471-2253 Impact factor: 2.217
Baseline characteristics of patients and surgical procedures
| 62.7 ± 17.1 | |
| 11 (31.4) | |
| I | 2 (5.7) |
| II | 6 (17.1) |
| III | 9 (25.7) |
| IV | 17 (48.6) |
| V | 1 (2.9) |
| 11.01 ± 1.92 | |
| 350 [20, 1350] | |
| 0 [0, 779] | |
| Hepatobiliary surgery | 6 (17.1) |
| Neurosurgery | 6 (17.1) |
| Abdominal surgery | 5 (14.2) |
| Urological surgery | 4 (11.4) |
| Abdominal aortic aneurysm | 3 (8.6) |
| Otolarynx surgery | 3 (8.6) |
| Spinal surgery | 3 (8.6) |
| Obstetrics-Gynecology surgery | 1 (2.9) |
| Debridement | 1 (2.9) |
| Others | 3 (8.6) |
Abbreviations: ASA American Society of Anesthesiologists
Fig. 1Correlation and agreement between point-of-care testings and the reference central laboratory for hemoglobin measurement. a Scatter plot with Pearson correlation analysis. The red color line showed a linear regression curve, where the light-red band represented the 95% confidence interval. b Bland-Altman analysis. A horizontal solid line corresponds to the estimated bias, while two horizontal dash lines represent the upper and lower prediction limits, corresponding to the 95% limit of agreement
The systematic comparison of five hemoglobin measurements regarding correlation, agreement, and assay practicality (n = 48 specimens)
| 11.2 ± 1.9 | 1.000 | – | – | – | – | 6 | 30–60 | 1.6 | |
| 11.7 ± 1.9 | 0.905 | 0.46 | 4.1 | 0.83 | −1.16, 2.08 | 4 | 6–10 | 0.1 | |
| 11.1 ± 1.8 | 0.922 | −0.18 | 1.6 | 0.74 | −1.63, 1.28 | 4 | 1–2 | 1.3 | |
| 11.1 ± 1.8 | 0.941 | −0.15 | 1.4 | 0.65 | −1.41, 1.12 | 4 | 2–3 | 8.1 | |
| 11.4 ± 2.2 | 0.670 | 0.13 | 1.2 | 1.66 | −3.12, 3.39 | 2 | < 1 | 65.6 | |
aDetails in the Materials and Methods section
bBased on the exchange rate on May 22, 2019. Note that the unit cost can vary in different settings and countries