Literature DB >> 32286967

3-D X-Ray-Induced Acoustic Computed Tomography With a Spherical Array: A Simulation Study on Bone Imaging.

Yang Li, Pratik Samant, Siqi Wang, A Behrooz, Dengwang Li, Liangzhong Xiang.   

Abstract

X-ray-induced acoustic computed tomography (XACT) is a promising imaging modality combining high X-ray absorption contrast with the 3-D propagation advantages provided by high-resolution ultrasound waves. The purpose of this study was to optimize the configuration of a 3-D XACT imaging system for bone imaging. A 280 ultrasonic sensors with peak frequency of 10 MHz was designed to distribute on a spherical surface to optimize the 3-D volumetric imaging capability. We performed both theoretical calculations and simulations of this optimized XACT imaging configuration on a mouse-sized digital phantom containing various X-ray absorption coefficients. Iteration algorithm based on total variation has been used for 3-D XACT image reconstruction. The spatial resolution of imaging was estimated to about [Formula: see text] along both axial and lateral directions. We simulate XACT imaging of bone microstructures using digital phantoms generated from micro-CT images of real biological samples, showing that XACT imaging can provide high-resolution imaging of the mouse paw. Results of this study will greatly enhance the potential of XACT imaging in the evaluation of bone diseases for future clinical use.

Entities:  

Mesh:

Year:  2020        PMID: 32286967      PMCID: PMC7394001          DOI: 10.1109/TUFFC.2020.2983732

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  27 in total

Review 1.  Role of magnetic resonance for assessing structure and function of trabecular bone.

Authors:  Felix W Wehrli; Punam K Saha; Bryon R Gomberg; Hee Kwon Song; Peter J Snyder; Maria Benito; Alex Wright; Richard Weening
Journal:  Top Magn Reson Imaging       Date:  2002-10

2.  Video rate optoacoustic tomography of mouse kidney perfusion.

Authors:  Andreas Buehler; Eva Herzog; Daniel Razansky; Vasilis Ntziachristos
Journal:  Opt Lett       Date:  2010-07-15       Impact factor: 3.776

3.  Adaptations in trabecular bone microarchitecture in Olympic athletes determined by 7T MRI.

Authors:  Gregory Chang; S Kubilay Pakin; Mark E Schweitzer; Punam K Saha; Ravinder R Regatte
Journal:  J Magn Reson Imaging       Date:  2008-05       Impact factor: 4.813

4.  Automated Quantitative Bone Analysis in In Vivo X-ray Micro-Computed Tomography.

Authors:  Ali Behrooz; Peet Kask; Jeff Meganck; Joshua Kempner
Journal:  IEEE Trans Med Imaging       Date:  2017-06-06       Impact factor: 10.048

5.  X-ray acoustic computed tomography with pulsed x-ray beam from a medical linear accelerator.

Authors:  Liangzhong Xiang; Bin Han; Colin Carpenter; Guillem Pratx; Yu Kuang; Lei Xing
Journal:  Med Phys       Date:  2013-01       Impact factor: 4.071

6.  Monolithic Multiband CMUTs for Photoacoustic Computed Tomography With In Vivo Biological Tissue Imaging.

Authors:  Sio Hang Pun; Yuanyu Yu; Jian Zhang; Jiujiang Wang; Ching-Hsiang Cheng; Kin Fong Lei; Zhen Yuan; Peng Un Mak
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-03       Impact factor: 2.725

7.  Real-time photoacoustic sensing for photo-mediated ultrasound therapy.

Authors:  Wei Zhang; Yu Qin; Xinyi Xie; Zizhong Hu; Yannis M Paulus; Xinmai Yang; Xueding Wang
Journal:  Opt Lett       Date:  2019-08-15       Impact factor: 3.776

8.  Fracture site-specific deficits in bone size and volumetric density in men with spine or hip fractures.

Authors:  E Seeman; Y Duan; C Fong; J Edmonds
Journal:  J Bone Miner Res       Date:  2001-01       Impact factor: 6.741

9.  High-resolution peripheral QCT imaging of bone micro-structure in adolescents.

Authors:  M Burrows; D Liu; H McKay
Journal:  Osteoporos Int       Date:  2009-03-26       Impact factor: 4.507

10.  Determinants of bone damage: An ex-vivo study on porcine vertebrae.

Authors:  Mohammad J Mirzaali; Flavia Libonati; Davide Ferrario; Luca Rinaudo; Carmelo Messina; Fabio M Ulivieri; Bruno M Cesana; Matteo Strano; Laura Vergani
Journal:  PLoS One       Date:  2018-08-16       Impact factor: 3.240

View more
  5 in total

1.  A simulation study of ionizing radiation acoustic imaging (iRAI) as a real-time dosimetric technique for ultra-high dose rate radiotherapy (UHDR-RT).

Authors:  Noora H Ba Sunbul; Wei Zhang; Ibrahim Oraiqat; Dale W Litzenberg; Kwok L Lam; Kyle Cuneo; Jean M Moran; Paul L Carson; Xueding Wang; Shaun D Clarke; Martha M Matuszak; Sara A Pozzi; Issam El Naqa
Journal:  Med Phys       Date:  2021-09-08       Impact factor: 4.071

2.  X-Ray-Induced Acoustic Computed Tomography (XACT): Initial Experiment on Bone Sample.

Authors:  Elijah Robertson; Pratik Samant; Siqi Wang; Tiffany Tran; Xuanrong Ji; Liangzhong Xiang
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2021-03-26       Impact factor: 2.725

3.  Model-Based X-Ray-Induced Acoustic Computed Tomography.

Authors:  Prabodh Kumar Pandey; Siqi Wang; Hari Om Aggrawal; Kristina Bjegovic; Salime Boucher; Liangzhong Xiang
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2021-11-23       Impact factor: 2.725

4.  Synchrotron X-ray induced acoustic imaging.

Authors:  Seongwook Choi; Eun-Yeong Park; Sinyoung Park; Jong Hyun Kim; Chulhong Kim
Journal:  Sci Rep       Date:  2021-02-18       Impact factor: 4.379

5.  Reconstruction Algorithm-Based Ultrasonic and Spiral CT Images in Evaluating the Effects of Dexmedetomidine Anesthesia for Acute Abdomen.

Authors:  Pinghua Tian; Shuhong Zhang; Linling Guo
Journal:  Comput Math Methods Med       Date:  2021-12-28       Impact factor: 2.238

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.