Literature DB >> 28600241

Automated Quantitative Bone Analysis in In Vivo X-ray Micro-Computed Tomography.

Ali Behrooz, Peet Kask, Jeff Meganck, Joshua Kempner.   

Abstract

Measurement and analysis of bone morphometry in 3D micro-computed tomography volumes using automated image processing and analysis improve the accuracy, consistency, reproducibility, and speed of preclinical osteological research studies. Automating segmentation and separation of individual bones in 3D micro-computed tomography volumes of murine models presents significant challenges considering partial volume effects and joints with thin spacing, i.e., 50 to [Formula: see text]. In this paper, novel hybrid splitting filters are presented to overcome the challenge of automated bone separation. This is achieved by enhancing joint contrast using rotationally invariant second-derivative operators. These filters generate split components that seed marker-controlled watershed segmentation. In addition, these filters can be used to separate metaphysis and epiphysis in long bones, e.g., femur, and remove the metaphyseal growth plate from the detected bone mask in morphometric measurements. Moreover, for slice-by-slice stereological measurements of long bones, particularly curved bones, such as tibia, the accuracy of the analysis can be improved if the planar measurements are guided to follow the longitudinal direction of the bone. In this paper, an approach is presented for characterizing the bone medial axis using morphological thinning and centerline operations. Building upon the medial axis, a novel framework is presented to automatically guide stereological measurements of long bones and enhance measurement accuracy and consistency. These image processing and analysis approaches are combined in an automated streamlined software workflow and applied to a range of in vivo micro-computed tomography studies for validation.

Entities:  

Mesh:

Year:  2017        PMID: 28600241     DOI: 10.1109/TMI.2017.2712571

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  3 in total

1.  3-D X-Ray-Induced Acoustic Computed Tomography With a Spherical Array: A Simulation Study on Bone Imaging.

Authors:  Yang Li; Pratik Samant; Siqi Wang; A Behrooz; Dengwang Li; Liangzhong Xiang
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2020-04-06       Impact factor: 2.725

Review 2.  Guidelines for Micro-Computed Tomography Analysis of Rodent Dentoalveolar Tissues.

Authors:  Michael B Chavez; Emily Y Chu; Vardit Kram; Luis F de Castro; Martha J Somerman; Brian L Foster
Journal:  JBMR Plus       Date:  2021-03-03

3.  Ex vivo evaluation of an atherosclerotic human coronary artery via histology and high-resolution hard X-ray tomography.

Authors:  Marzia Buscema; Simone E Hieber; Georg Schulz; Hans Deyhle; Alexander Hipp; Felix Beckmann; Johannes A Lobrinus; Till Saxer; Bert Müller
Journal:  Sci Rep       Date:  2019-10-04       Impact factor: 4.379

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.