Literature DB >> 23876870

Intraocular pressure after implantation of the Visian Implantable Collamer Lens With CentraFLOW without iridotomy.

Alejandro Higueras-Esteban1, Amanda Ortiz-Gomariz, Ramón Gutiérrez-Ortega, César Villa-Collar, Juan P Abad-Montes, Paulo Fernandes, José M González-Méijome.   

Abstract

PURPOSE: To compare the intraocular pressure (IOP) values during a 3-month period after implantation of the new Visian Implantable Collamer Lens (ICL; STAAR Surgical Company, Nidau, Switzerland) V4c design with CentraFLOW technology without iridotomy using a standard procedure followed by implantation of the conventional ICL V4b model.
DESIGN: Retrospective cohort study.
METHODS: This study included 17 eyes implanted with the ICL V4b model and 18 eyes implanted with the ICL V4c model. The mean preoperative spherical equivalent refractions were -7.48 ± 5.00 diopters and -8.66 ± 4.2 diopters, respectively. We compared the best-corrected distance visual acuity before surgery with the uncorrected distance visual acuity after surgery. The intraocular pressure (IOP) was measured 1 week, 1 month, and 3 months after surgery. The central vault at 3 months was measured using optical coherence tomography.
RESULTS: Three months after surgery, the mean uncorrected distance visual acuities were -0.09 ± 0.12 logarithm of the minimal angle of resolution units with the V4b and -0.07 ± 0.11 logarithm of the minimal angle of resolution units with the V4c. The mean distances between the ICL and the anterior crystalline lens surface were 557 ± 224 μm and 528 ± 268 μm for the V4b and V4c, respectively (P = .73). After 1 week and 1 month, the mean IOPs were 13.7 and 13.3 mm Hg and 14.7 and 15.1 mm Hg, respectively. There were no significant differences in IOP within or between groups during the follow-up period (P > .05, for all comparisons).
CONCLUSIONS: The new ICL with the CentraFLOW design seems to provide similar results as its predecessors for the correction of moderate to high myopia and maintenance of safe IOP levels without iridotomy.
Copyright © 2013 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2013        PMID: 23876870     DOI: 10.1016/j.ajo.2013.05.018

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  24 in total

1.  Theoretical study on the need for laser iridotomy in an implantable collamer lens with a hole using computational fluid dynamics.

Authors:  T Kawamorita; K Shimizu; N Shoji
Journal:  Eye (Lond)       Date:  2017-01-20       Impact factor: 3.775

Review 2.  [Phakic intraocular lenses].

Authors:  T Kohnen; M Shajari
Journal:  Ophthalmologe       Date:  2016-06       Impact factor: 1.059

3.  [Intraocular pressure after implantation of an ICL with aquaport : Development of intraocular pressure after implantation of an ICL (model V4c) with aquaport without iridotomy].

Authors:  B Repplinger; T Kohnen
Journal:  Ophthalmologe       Date:  2018-01       Impact factor: 1.059

4.  Implantable collamer lens V4b and V4c for correction of high myopia.

Authors:  Vipul Bhandari; Smitha Karandikar; Jagdeesh K Reddy; Kirti Relekar
Journal:  J Curr Ophthalmol       Date:  2016-02-09

5.  Comparison of surgical time and IOP spikes with two ophthalmic viscosurgical devices following Visian STAAR (ICL, V4c model) insertion in the immediate postoperative period.

Authors:  Sri Ganesh; Sheetal Brar
Journal:  Clin Ophthalmol       Date:  2016-01-27

Review 6.  Meta-analysis and review: effectiveness, safety, and central port design of the intraocular collamer lens.

Authors:  Mark Packer
Journal:  Clin Ophthalmol       Date:  2016-06-09

7.  Comparison of early changes in and factors affecting vault following posterior chamber phakic Implantable Collamer Lens implantation without and with a central hole (ICL V4 and ICL V4c).

Authors:  Xun Chen; Huamao Miao; Rajeev Krishnan Naidu; Xiaoying Wang; Xingtao Zhou
Journal:  BMC Ophthalmol       Date:  2016-09-07       Impact factor: 2.209

8.  Posterior chamber collagen copolymer phakic intraocular lens with a central hole for moderate-to-high myopia: First experience in China.

Authors:  Xinfang Cao; Weiliang Wu; Yang Wang; Chen Xie; Jianping Tong; Ye Shen
Journal:  Medicine (Baltimore)       Date:  2016-09       Impact factor: 1.889

Review 9.  Phakic Intraocular Lenses and their Special Indications.

Authors:  Roberto Pineda; Tulika Chauhan
Journal:  J Ophthalmic Vis Res       Date:  2016 Oct-Dec

10.  Anterior Chamber Angle Evaluation following Phakic Posterior Chamber Collamer Lens with CentraFLOW and Its Correlation with ICL Vault and Intraocular Pressure.

Authors:  Sherif A Eissa; Sherin H Sadek; Mohamed W A El-Deeb
Journal:  J Ophthalmol       Date:  2016-12-08       Impact factor: 1.909

View more