| Literature DB >> 36151534 |
Ying Wang1, Ruibo Yang1, Yue Huang1, Chen Zhang1, Hui Liu1, Zhe Jia1, Shaozhen Zhao2.
Abstract
BACKGROUND: Implantable collamer lens (ICL) surgery techniques are constantly progressing. The purpose of this study was to investigate the application effect of the modified technique and its impact on the change in corneal astigmatism in EVO-ICL surgery.Entities:
Keywords: Corneal endothelial; Corneal surgically induced astigmatism; Implantable collamer lens; Intraocular pressure; Modified technique
Mesh:
Year: 2022 PMID: 36151534 PMCID: PMC9502894 DOI: 10.1186/s12886-022-02603-8
Source DB: PubMed Journal: BMC Ophthalmol ISSN: 1471-2415 Impact factor: 2.086
Baseline demographic indicators of the study population
| Parameters | Modified Technique Group | Standard Technique Group( | |||
|---|---|---|---|---|---|
| MEAN ± SD | RANGE | MEAN ± SD | RANGE | ||
| Eye (n) | 80 | 73 | |||
| Patients (n) | 41 | 40 | |||
| Sex (Female:Male) | 58:22 | 51:22 | 0.72 | ||
| Age (year) | 26.83 ± 6.90 | 18,46 | 27.90 ± 6.78 | 18,44 | 0.48 |
| Spherical refraction (D) | -9.52 ± 2.83 | -5.25, -18.00 | -9.01 ± 2.43 | -4.25, -14.00 | 0.24 |
| Cylinder refraction (D) | -1.32 ± 0.87 | -3.25,0 | -1.34 ± 0.88 | -3.50,0 | 0.85 |
| Manifest spherical equivalent (D) | -10.18 ± 2.74 | -5.25, -19.25 | -9.68 ± 2.63 | -4.50, -15.50 | 0.26 |
| Total corneal astigmatism | |||||
| Magnitude (D) | 1.46 ± 0.85 | 0.20, 4.0 | 1.53 ± 0.93 | 0.30,4.2 | 0.63 |
| Meridian (°) | 89.74 ± 17.31 | 9.50,156.0 | 91.15 ± 14.58 | 49.60,161.0 | 0.59 |
| Anterior corneal astigmatism | |||||
| Magnitude (D) | 1.47 ± 0.83 | 0.30,4.00 | 1.56 ± 0.88 | 0.30,3.90 | 0.53 |
| Meridian (°) | 90.21 ± 16.27 | 17.30,135.5 | 92.06 ± 14.04 | 54.40,164.9 | 0.45 |
| Posterior corneal astigmatism | |||||
| Magnitude (D) | 0.44 ± 0.14 | 0.20,0.90 | 0.42 ± 0.17 | 0.10,0.90 | 0.54 |
| Meridian (°) | 90.08 ± 11.23 | 11.00,106.00 | 90.98 ± 12.30 | 14.10,117.70 | 0.64 |
| UDVA (log MAR) | 1.44 ± 0.29 | 0.70,2.00 | 1.37 ± 0.26 | 0.70,2.00 | 0.11 |
| CDVA (log MAR) | 0.02 ± 0.04 | 0.00,0.20 | 0.02 ± 0.05 | -0.10,0.20 | 0.75 |
| IOP (mmHg) | 14.81 ± 2.54 | 10.30,20.50 | 14.55 ± 2.54 | 9.40,19.30 | 0.54 |
| AL (mm) | 27.51 ± 1.54 | 24.60,31.88 | 27.14 ± 1.29 | 24.16,30.68 | 0.11 |
| ACD (mm) | 3.21 ± 0.19 | 2.81,3.60 | 3.26 ± 0.26 | 2.80,3.81 | 0.21 |
| WTW (mm) | 11.57 ± 0.35 | 10.76,12.62 | 11.49 ± 0.34 | 10.80,12.37 | 0.17 |
| CCT (µm) | 516.8 ± 32.45 | 431.00,633.00 | 513.2 ± 30.51 | 457.00,591.00 | 0.49 |
| ECD (cells/mm2) | 3064 ± 257.6 | 2515,3868 | 3001 ± 309.8 | 2380,3717 | 0.17 |
Fig. 1Mean IOP (a), ACD (b), and vault (c) of the modified technique group and the standard technique group at each follow-up different time points. * P < 0.05, the error bar indicates the standard deviation
Mean absolute SIA of the total, anterior, and posterior corneas at one month after operation between the two groups
| Parameters | Modified Technique Group( | Standard Technique Group( | |||
|---|---|---|---|---|---|
| MEAN ± SD | RANGE | MEAN ± SD | RANGE | ||
| Total corneal SIA (D) | 0.60 ± 0.30 | 0.10,1.65 | 0.64 ± 0.30 | 0.17,1.58 | 0.45 |
| Anterior corneal SIA (D) | 0.60 ± 0.26 | 0.14,1.38 | 0.62 ± 0.25 | 0.10,1.36 | 0.79 |
| Posterior corneal SIA (D) | 0.15 ± 0.09 | 0.0,0.40 | 0.14 ± 0.09 | 0.0,0.40 | 0.52 |
Fig. 2The SIA of the total cornea of the modified technique group (centroid: 0.48 × 17° ± 0.48 D) and the standard technique group (centroid: 0.56 × 19° ± 0.44 D) one month after surgery is shown in a double-angle plot. No significant difference was found in SIA between the two groups in centroid analysis (P > 0.05)
Fig. 3The SIA of the anterior cornea of the modified technique group (centroid: 0.48 × 18° ± 0.45 D) and the standard technique group (centroid: 0.53 × 22° ± 0.41 D) one month after surgery is shown in a double-angle plot. No significant difference was found in SIA between the two groups in centroid analysis (P > 0.05)