| Literature DB >> 32280192 |
Abstract
BACKGROUND: The purpose of this retrospective study was to evaluate cylinder axis agreement between manifest refraction (MR), cycloplegic refraction (CR), Allegro Oculyzer ІІ and Allegro Topolyzer-Vario.Entities:
Keywords: Allegro Oculyzer ІІ; Allegro Topolyzer-Vario; LASIK; PRK; cycloplegic refraction; manifest refraction
Year: 2020 PMID: 32280192 PMCID: PMC7127776 DOI: 10.2147/OPTH.S237757
Source DB: PubMed Journal: Clin Ophthalmol ISSN: 1177-5467
Distribution of the Studied Cases According to Different Parameters (n = 156)
| No. (%) | |
|---|---|
| Age (Years) | |
| Mean ± SD | 27.4 ± 7.7 |
| Median (Min. – Max.) | 26 (18–49) |
| Refractive Surgery | |
| PRK | 50 (32.1%) |
| LASIK | 106 (67.9%) |
| Pachymetry (µm) | |
| Mean ± SD | 537.7 ± 34 |
| Median (Min. – Max.) | 533 (487–639) |
| Keratometric K1 (D) | |
| Mean ± SD | 42.8 ± 1.4 |
| Median (Min. – Max.) | 42.8 (39.6–46.3) |
| Keratometric K2 (D) | |
| Mean ± SD | 44.6 ± 1.6 |
| Median (Min. – Max.) | 44.6 (41.5–50.6) |
| Sphere (D) | |
| Mean ± SD | −2 ± 3 |
| Median (Min. – Max.) | −1.5 (−8 – 5.5) |
| Cylinder (D) | |
| Mean ± SD | −1.9 ± 1 |
| Median (Min. – Max.) | −1.5 (−4.5 - −0.5) |
| Manifest Refraction Cylinder Axis | |
| Mean ± SD | 95 ± 66.4 |
| Median (Min. – Max.) | 101.5 (3–192) |
| Cycloplegic Refraction Cylinder Axis | |
| Mean ± SD | 92.7 ± 66.1 |
| Median (Min. – Max.) | 98.5 (1–194) |
| Allegro Oculyzer ІІ Cylinder Axis | |
| Mean ± SD | 94.8 ± 68.5 |
| Median (Min. – Max.) | 107.5 (2–190) |
| Allegro Topolyzer-Vario Cylinder Axis | |
| Mean ± SD | 94.5 ± 69.3 |
| Median (Min. – Max.) | 106 (0–185) |
| 1 Month Sphere (D) | |
| Mean ± SD | 0 ± 0.1 |
| Median (Min. – Max.) | 0 (−0.3–0.5) |
| 1 Month Cylinder (D) | |
| Mean ± SD | 0 ± 0.1 |
| Median (Min. – Max.) | 0 (−0.5–0) |
| 1 Month UCVA | |
| Mean ± SD | 1 ± 0.1 |
| Median (Min. – Max.) | 1 (0.8–1) |
Abbreviations: SD, standard deviation; PRK, photorefractive keratectomy; LASIK, laser-assisted in situ keratomileusis; UCVA, uncorrected visual acuity.
Intra Class Correlation Coefficient for Cylinder Axis Agreement
| ICC Coefficient | 95% C.I | p | |
|---|---|---|---|
| MR Axis vs. | |||
| CR axis | 0.996 | 0.995–0.997 | <0.001* |
| Oculyzer axis | 0.991 | 0.988–0.993 | <0.001* |
| Topolyzer axis | 0.989 | 0.985–0.992 | <0.001* |
| CR Axis vs. | |||
| Oculyzer axis | 0.990 | 0.986–0.993 | <0.001* |
| Topolyzer axis | 0.991 | 0.987–0.993 | <0.001* |
| Oculyzer Axis vs. | |||
| Topolyzer axis | 0.994 | 0.992–0.996 | <0.001* |
Note: *Statistically significant at p ≤ 0.05.
Abbreviations: ICC, intra class correlation coefficient; CI, confidence interval; MR, manifest refraction; CR, cycloplegic refraction.
Pearson Correlation Coefficient for Cylinder Axis Agreement
| Mean Difference (SD) | 95% Limits of Agreement | Pearson Correlation Coefficient (r)* | p-value | |
|---|---|---|---|---|
| MR axis - CR axis | 2.37(2.92) | 14.0 to −9.2 | 0.996 | <0.001* |
| MR axis - Oculyzer axis | 0.25(9.02) | 17.9 to −17.4 | 0.992 | <0.001* |
| MR axis - Topolyzer axis | 0.55(9.94) | 20.0 to −18.9 | 0.990 | <0.001* |
| CR axis - Oculyzer axis | −2.12(9.50) | 16.5 to −20.7 | 0.991 | <0.001* |
| CR axis - Topolyzer axis | −1.81(9.33) | 16.5 to −20.1 | 0.992 | <0.001* |
| Oculyzer axis - Topolyzer axis | 0.30(7.53) | 15.1 to −14.5 | 0.994 | <0.001* |
Note: *Statistically significant at p ≤ 0.05.
Abbreviations: SD, standard deviation; r, Pearson coefficient; MR, manifest refraction; CR, cycloplegic refraction.
Figure 1Bland–Altman plots of cylinder axis agreement between manifest refraction (MR), cycloplegic refraction (CR), Allegro Oculyzer ІІ and Allegro Topolyzer-Vario. The bold horizontal line demonstrates the mean difference and the dotted lines above and below represent the 95% limits of agreement (LoA) interval. A: MR axis - CR axis. B: MR axis - Oculyzer axis. C: MR axis - Topolyzer axis. D: CR axis - Oculyzer axis. E: CR axis - Topolyzer axis. F: Oculyzer axis - Topolyzer axis.
Figure 2Allegro Oculyzer ІІ and Allegro Topolyzer-Vario cylinder axis disagreement in four studied cases.