Correlation between central corneal thickness, anterior chamber depth, and corneal keratometry as measured by Oculyzer II and WaveLight OB820 in preoperative cataract surgery patients.

A John Kanellopoulos1, George Asimellis.   

Abstract

PURPOSE: To compare and correlate central corneal thickness (CCT), anterior chamber depth (ACD), and keratometric (flat and steep K) measurements using two anterior segment imaging methods, a Scheimpflug camera system (Oculyzer II [Oculus Optikgeräte GmbH]) and a partial coherence biometry system (WaveLight OB820 [Alcon Laboratories Inc]) in eyes undergoing cataract surgery.
METHODS: Ninety patients (mean age: 66±13 years [range: 32 to 88 years]) underwent preoperative measurement of CCT, ACD, and keratometric measurements by Scheimpflug tomography (Oculyzer II) and optical low coherence reflectometry (WaveLight OB820). Interdevice agreement and correlation between the two techniques were assessed.
RESULTS: All measurements were highly correlated and showed no clinically significant difference between methods. Mean CCT was 554.21±39.07 μm and 546.59±37.75 μm for the Oculyzer II and WaveLight OB820, respectively (R²=0.9268). Mean ACD was 2.63±0.44 mm and 2.63±0.43 mm for the Oculyzer II and WaveLight OB820, respectively (R(2)=0.9488). The principal meridian keratometric values were also highly correlated. Mean flat K was 42.88±1.50 diopters (D) and 42.96±1.40 D for the Oculyzer II and WaveLight OB820, respectively (R²=0.8741). Mean steep K was 44.08±1.79 D and 44.26±1.95 D for the Oculyzer II and WaveLight OB820, respectively (R(2)=0.9159).
CONCLUSIONS: Our data show that the Oculyzer II and WaveLight OB820 provide measurements that are in agreement with published values for CCT and ACD in patients. Excellent agreement for CCT and ACD was found between the two devices, as demonstrated by a high degree of correlation and linearity, in addition to minimal bias. Thus, CCT, ACD, and K measurements by these instruments can both be used in clinical preparation, and their agreement is an ensuring precision factor for cataract and refractive surgeons. Copyright 2012, SLACK Incorporated.

Entities:  

Mesh:

Year:  2012        PMID: 23092131     DOI: 10.3928/1081597X-20121005-07

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  12 in total

1.  Age- and sex-related differences in the measures of anterior segment parameters in a myopic clinical sample using Pentacam Scheimpflug tomography.

Authors:  Samuel Kyei; John Baptist Vianney Abowine; Ebenezer Zaabaar; Samuel Bert Boadi-Kusi; Frank Assiamah; Mohammed Abdul-Kabir; Kofi Asiedu
Journal:  Int Ophthalmol       Date:  2022-01-27       Impact factor: 2.031

2.  Comparison of Placido disc and Scheimpflug image-derived topography-guided excimer laser surface normalization combined with higher fluence CXL: the Athens Protocol, in progressive keratoconus.

Authors:  Anastasios John Kanellopoulos; George Asimellis
Journal:  Clin Ophthalmol       Date:  2013-07-18

3.  Clear-cornea cataract surgery: pupil size and shape changes, along with anterior chamber volume and depth changes. A Scheimpflug imaging study.

Authors:  Anastasios John Kanellopoulos; George Asimellis
Journal:  Clin Ophthalmol       Date:  2014-10-24

4.  Topography-modified refraction (TMR): adjustment of treated cylinder amount and axis to the topography versus standard clinical refraction in myopic topography-guided LASIK.

Authors:  Anastasios John Kanellopoulos
Journal:  Clin Ophthalmol       Date:  2016-11-03

5.  Comparison of the biometric measurements calculated with Zeiss IOL-Master and WaveLight OB-820.

Authors:  Georgios Labiris; Panagiota Ntonti; Konstantinos Ntitsos; Andreas Katsanos; Haris Sideroudi; Vasilios Kozobolis
Journal:  Clin Ophthalmol       Date:  2017-04-21

6.  Anterior segment optical coherence tomography: assisted topographic corneal epithelial thickness distribution imaging of a keratoconus patient.

Authors:  A John Kanellopoulos; George Asimellis
Journal:  Case Rep Ophthalmol       Date:  2013-04-18

7.  Long-term bladeless LASIK outcomes with the FS200 Femtosecond and EX500 Excimer Laser workstation: the Refractive Suite.

Authors:  A John Kanellopoulos; George Asimellis
Journal:  Clin Ophthalmol       Date:  2013-02-21

8.  Comparison of high-resolution Scheimpflug and high-frequency ultrasound biomicroscopy to anterior-segment OCT corneal thickness measurements.

Authors:  Anastasios John Kanellopoulos; George Asimellis
Journal:  Clin Ophthalmol       Date:  2013-11-20

9.  Measurement of anterior segment parameters in Saudi adults with myopia.

Authors:  Lujain S Alrajhi; Kholoud A Bokhary; Ahmed A Al-Saleh
Journal:  Saudi J Ophthalmol       Date:  2018-05-14

10.  Cylinder Axis Agreement: Unexpected Scenarios.

Authors:  Karim Mahmoud Nabil
Journal:  Clin Ophthalmol       Date:  2020-03-31
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.