Literature DB >> 19954152

Anisotropic swelling behavior of the cornea.

Toyoaki Matsuura1, Hitoe Ikeda, Naokazu Idota, Ryuhei Motokawa, Yoshiaki Hara, Masahiko Annaka.   

Abstract

The phase equilibrium property and structural and dynamical properties of pig cornea were studied by macroscopic observation of swelling behavior, dynamic light scattering (DLS), and small-angle X-ray scattering (SAXS) under various conditions. It was found that the corneal gel collapses into a compact state isotropically or anisotropically depending on the external conditions. The corneal gel collapses uniformly into a compact state at a temperature above 55 degrees C because of the denaturation of collagen, whereas it collapses along an axis parallel to the optic axis with increasing NaCl concentration. Anisotropic deswelling was also observed during desiccation. SAXS measurements revealed that the periodicity of the collagen fiber of the cornea does not change even at higher NaCl concentration, which indicates that hydration and dehydration resulting from changes in salt concentration simply cause swelling and deswelling of the glycosaminoglycan (GAG), which is located between the regular two-dimensional lattices of collagen fibers, which obliges the change in thickness. From observations of the dynamics of light scattered by the corneal gel, intensity autocorrelation functions that revealed two independent diffusion coefficients were obtained. Divergent behavior in the measured total scattered light intensities and diffusion coefficients with varying temperature was observed. That is, a slowing of the dynamic modes accompanied by increased "static" scattered intensities was observed. This is indicative of the occurrence of a phase transition as a function of temperature.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19954152     DOI: 10.1021/jp907232h

Source DB:  PubMed          Journal:  J Phys Chem B        ISSN: 1520-5207            Impact factor:   2.991


  6 in total

1.  Topography-modified refraction (TMR): adjustment of treated cylinder amount and axis to the topography versus standard clinical refraction in myopic topography-guided LASIK.

Authors:  Anastasios John Kanellopoulos
Journal:  Clin Ophthalmol       Date:  2016-11-03

2.  Topography-Guided Femto-LASIK in Virgin Eyes: Treating Manifest versus Measured Astigmatism.

Authors:  Shereef Mohammed Abdelwahab; Abdelmonem M Hamed; Ahmed Sherin M Bayoumy; Maha Attaia Elfayoumi
Journal:  Clin Ophthalmol       Date:  2020-12-18

3.  Long-term bladeless LASIK outcomes with the FS200 Femtosecond and EX500 Excimer Laser workstation: the Refractive Suite.

Authors:  A John Kanellopoulos; George Asimellis
Journal:  Clin Ophthalmol       Date:  2013-02-21

4.  Treatment of moderate-to-high hyperopia with the WaveLight Allegretto 400 and EX500 excimer laser systems.

Authors:  Manoj Motwani; Ronald Pei
Journal:  Clin Ophthalmol       Date:  2017-05-24

5.  Outcomes of LASIK for Myopia or Myopic Astigmatism Correction with the FS200 Femtosecond Laser and EX500 Excimer Laser Platform.

Authors:  Muanploy Niparugs; Napaporn Tananuvat; Winai Chaidaroon; Chulaluck Tangmonkongvoragul; Somsanguan Ausayakhun
Journal:  Open Ophthalmol J       Date:  2018-05-18

6.  Cylinder Axis Agreement: Unexpected Scenarios.

Authors:  Karim Mahmoud Nabil
Journal:  Clin Ophthalmol       Date:  2020-03-31
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.