Literature DB >> 10225603

Evaluation of the white-coat effect in cats.

A M Belew1, T Barlett, S A Brown.   

Abstract

The diagnosis and management of systemic hypertension in cats requires a reliable method for measurement of systemic arterial blood pressure (BP) in clinical patients. Unfortunately, the setting of a clinical practice and the act of measuring BP might raise BP and heart rate (HR), an effect referred to as the white-coat effect in human patients. The purpose of the present study was to determine if a white-coat effect was experienced by cats. Radiotelemetric implants were used to measure BP and HR in 13 conscious cats in a research colony while undisturbed in their cages and while subjected to simulated visits to a veterinarian's office. The white-coat effect was taken to be the difference between the overall 24-hour average value for parameters of BP and HR and the corresponding value during the simulated office visit. A white-coat effect was observed in cats. In healthy cats, the systolic BP measured during the examination period of the simulated office visit exceeded the 24-hour average systolic BP by 17.6+/-1.5 mm Hg. However, marked heterogeneity occurred in the pattern and magnitude of the increase in systolic BP above the 24-hour baseline and the increase varied between 75.3 and -27.2 mm Hg for the healthy cats. Variation in response to the simulated office visit was observed among cats and among visits by the same cat. During an office visit, the magnitude of the white-coat effect tended to decrease, but not disappear, over time. The magnitude of the white-coat effect varied when cats were subjected to 5 repeat office visits, but did not diminish in the group as a whole. The mean increase in systolic BP during the examination (22.3+/-0.9 mm Hg) was greater (P < .05) in cats with renal insufficiency. Although the heterogeneity of response expected from companion animals might be greater than that observed in these colony cats, these results indicate that veterinarians should carefully consider the white-coat effect in evaluation of BP in cats. A quiet, undisturbed environment and adequate time for acclimation should be included in the standard protocol for measurements of BP. Because of day-to-day variation in the white-coat effect in individual cats, multiple serial measurements following a standard protocol should provide the best estimate of BP in cats.

Entities:  

Mesh:

Year:  1999        PMID: 10225603     DOI: 10.1892/0891-6640(1999)013<0134:eotwce>2.3.co;2

Source DB:  PubMed          Journal:  J Vet Intern Med        ISSN: 0891-6640            Impact factor:   3.333


  24 in total

1.  Evaluation of oscillometric and Doppler ultrasonic methods of indirect blood pressure estimation in conscious dogs.

Authors:  Christopher E Haberman; Chang W Kang; Jefferson D Morgan; Scott A Brown
Journal:  Can J Vet Res       Date:  2006-07       Impact factor: 1.310

Review 2.  Non-invasive blood pressure measurement in animals: Part 1 - Techniques for measurement and validation of non-invasive devices.

Authors:  Alicia Skelding; Alexander Valverde
Journal:  Can Vet J       Date:  2020-04       Impact factor: 1.008

3.  Effect of attire on client perceptions of veterinarians.

Authors:  E Bentley; H Kellihan; C Longhurst; R Chun
Journal:  Vet J       Date:  2020-09-24       Impact factor: 2.688

4.  Pharmacodynamic effects of ivabradine, a negative chronotropic agent, in healthy cats.

Authors:  Richard E Cober; Karsten E Schober; Tony C A Buffington; Xiaobai Li; Sabine C Riesen; John D Bonagura
Journal:  J Vet Cardiol       Date:  2011-10-24       Impact factor: 1.701

5.  Comparison of home blood pressure and office blood pressure measurement in dogs and cats.

Authors:  Siu To Koo; Anthony P Carr
Journal:  Can J Vet Res       Date:  2022-07       Impact factor: 0.897

6.  Oscillometric and Doppler arterial blood pressure measurement in conscious goats.

Authors:  Olga Szaluś-Jordanow; Michał Czopowicz; Anna Świerk; Oktawia Szpinda; Magdalena Garncarz; Marcin Mickiewicz; Agata Moroz; Emilia Bagnicka; Jarosław Kaba
Journal:  Can J Vet Res       Date:  2018-10       Impact factor: 1.310

7.  Aortic thromboembolism in a basset hound-beagle crossbred dog with protein-losing nephropathy.

Authors:  Kathryn Gardiner
Journal:  Can Vet J       Date:  2020-03       Impact factor: 1.008

8.  Blood Pressure Measurements in 780 Apparently Healthy Cats.

Authors:  J R Payne; D C Brodbelt; V Luis Fuentes
Journal:  J Vet Intern Med       Date:  2016-12-01       Impact factor: 3.333

9.  Acupuncture effects on cardiac functions measured by cardiac magnetic resonance imaging in a feline model.

Authors:  Jen-Hsou Lin; Chen-Haw Shih; Krishna Kaphle; Leang-Shin Wu; Weng-Yih Tseng; Jen-Hwey Chiu; Tzu-Chi Lee; Ying-Ling Wu
Journal:  Evid Based Complement Alternat Med       Date:  2008-01-23       Impact factor: 2.629

10.  Cardiovascular-renal axis disorders in the domestic dog and cat: a veterinary consensus statement.

Authors:  J L Pouchelon; C E Atkins; C Bussadori; M A Oyama; S L Vaden; J D Bonagura; V Chetboul; L D Cowgill; J Elliot; T Francey; G F Grauer; V Luis Fuentes; N Sydney Moise; D J Polzin; A M Van Dongen; N Van Israël
Journal:  J Small Anim Pract       Date:  2015-09       Impact factor: 1.522

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.