Literature DB >> 9662782

A comparison of indirect blood pressure monitoring techniques in the anesthetized cat.

N A Caulkett1, S L Cantwell, D M Houston.   

Abstract

OBJECTIVE: To determine the accuracy of three indirect blood pressure monitoring techniques (oscillometric technique [OS], Doppler [DOP], and optical plethysmography [OP] [blood pressure determined with a pulse oximeter waveform]) when compared with direct arterial pressure measurement in cats. STUDY
DESIGN: Prospective study. ANIMAL POPULATION: Eight healthy (five female, three male), domestic short-hair cats weighing 3.5 +/- 0.8 kg
METHODS: Cats were anesthetized with isoflurane. The inspired concentration of isoflurane was adjusted to produce mild hypotension (80 to 100 mm Hg direct systolic), moderate hypotension (60 to 80 mm Hg direct systolic), and severe hypotension (< 60 mm Hg direct systolic). Indirect pressure measurements were obtained from the thoracic limb and compared with concurrent direct measurement using regression analysis and a modification of Bland and Altman's technique.
RESULTS: All three techniques underestimated systolic pressure. OS produced the best prediction of systolic pressure with a bias +/- precision of -15.9 +/- 8.1 mm Hg. DOP and OP were relatively inaccurate with a bias +/- precision of -25 +/- 7.4 mm Hg and -25 +/- 7.5 mm Hg. All three techniques correlated well with direct pressure with r values of 0.81, 0.88, and 0.88 for OS, DOP, and OP. DOP and OP provided an accurate prediction of direct mean arterial pressure with a bias +/- precision of -0.8 +/- 6 mm Hg and 0.6 +/- 5.5 mm Hg. Correlation was good between DOP and mean arterial pressure with r = 0.89. Correlation was also good between OP and mean arterial pressure with r = 0.90.
CONCLUSIONS: OS provided the most accurate prediction of direct systolic pressure. DOP and OP provided a good prediction of mean arterial pressure in the cat. CLINICAL RELEVANCE: All three of these techniques are useful for detecting trends. Direct monitoring of blood pressure should be considered if accurate blood pressure measurement is required.

Entities:  

Mesh:

Year:  1998        PMID: 9662782     DOI: 10.1111/j.1532-950x.1998.tb00143.x

Source DB:  PubMed          Journal:  Vet Surg        ISSN: 0161-3499            Impact factor:   1.495


  17 in total

1.  Evaluation of surgical outcome, complications, and mortality in dogs undergoing preoperative computed tomography angiography for diagnosis of an extrahepatic portosystemic shunt: 124 cases (2005-2014).

Authors:  Benjamin W Brunson; J Brad Case; Gary W Ellison; W Alexander Fox-Alvarez; Stanley E Kim; Matthew Winter; Fernando L Garcia-Pereira; Lisa L Farina
Journal:  Can Vet J       Date:  2016-01       Impact factor: 1.008

2.  The use of vascular access ports for blood collection in feline blood donors.

Authors:  Isabelle Aubert; Anthony C G Abrams-Ogg; Anne M Sylvestre; Doris H Dyson; Dana G Allen; Ian B Johnstone
Journal:  Can J Vet Res       Date:  2011-01       Impact factor: 1.310

3.  Comparison of invasive and oscillometric blood pressure measurement techniques in anesthetized camelids.

Authors:  Turi K Aarnes; John A E Hubbell; Phillip Lerche; Richard M Bednarski
Journal:  Can Vet J       Date:  2012-08       Impact factor: 1.008

Review 4.  Non-invasive blood pressure measurement in animals: Part 1 - Techniques for measurement and validation of non-invasive devices.

Authors:  Alicia Skelding; Alexander Valverde
Journal:  Can Vet J       Date:  2020-04       Impact factor: 1.008

Review 5.  Basics of monitoring equipment.

Authors:  Tanya Duke-Novakovski
Journal:  Can Vet J       Date:  2017-11       Impact factor: 1.008

6.  Vasopressor use in 41 critically ill cats (2007-2016).

Authors:  Nikki Licht; Elizabeth A Rozanski; John E Rush
Journal:  Can Vet J       Date:  2018-11       Impact factor: 1.008

7.  Use of a point-of-care beta-hydroxybutyrate sensor for detection of ketonemia in dogs.

Authors:  Debra W Henderson; Daniel P Schlesinger
Journal:  Can Vet J       Date:  2010-09       Impact factor: 1.008

8.  A Comparison of the Efficacy and Cardiopulmonary Effects of 3 Different Sedation Protocols in Otolemur garnettii.

Authors:  Kelsey R Finnie; Carissa P Jones; William D Dupont; Kenneth J Salleng; Katherine A Shuster
Journal:  J Am Assoc Lab Anim Sci       Date:  2020-07-21       Impact factor: 1.232

9.  Efficacy of preanesthetic intramuscular administration of ephedrine for prevention of anesthesia-induced hypotension in cats and dogs.

Authors:  Christine Egger; Mary-Ann McCrackin; Erik Hofmeister; Gwenola Touzot-Jourde; Bart Rohrbach
Journal:  Can Vet J       Date:  2009-02       Impact factor: 1.008

10.  Indirect arterial blood pressure measurement in healthy anesthetized cats using a device that combines oscillometry with photoplethysmography.

Authors:  Yasuhiro Heishima; Yasutomo Hori; Seishiro Chikazawa; Kazutaka Kanai; Fumio Hoshi; Naoyuki Itoh
Journal:  J Vet Med Sci       Date:  2016-03-18       Impact factor: 1.267

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.