Literature DB >> 14719697

Hemodynamic effects of sevoflurane in cats.

Bruno H Pypendop1, Jan E Ilkiw.   

Abstract

OBJECTIVE: To determine hemodynamic effects of 3 concentrations of sevoflurane in cats. ANIMALS: 6 cats. PROCEDURE: Cats were anesthetized with sevoflurane in oxygen. After instruments were inserted, end-tidal sevoflurane concentration was set at 1.25, 1.5, or 1.75 times the individual minimum alveolar concentration (MAC), which was determined in another study. Twenty-five minutes were allowed after each change of concentration. Heart rate; systemic and pulmonary arterial pressures; central venous pressure; pulmonary artery occlusion pressure; cardiac output; body temperature; arterial and mixed-venous pH, PCO2, PO2, oxygen saturation, and hemoglobin concentrations; PCV; and total protein and lactate concentrations were measured for each sevoflurane concentration before and during noxious stimulation. Arterial and mixed-venous bicarbonate concentrations, cardiac index, stroke index, rate-pressure product, systemic and pulmonary vascular resistance indices, left and right ventricular stroke work indices, PaO2, mixed-venous partial pressure of oxygen (PVO2), oxygen delivery, oxygen consumption, oxygen-extraction ratio, alveolar-to-arterial oxygen difference, and venous admixture were calculated. Spontaneous and mechanical ventilations were studied during separate experiments.
RESULTS: Mode of ventilation did not significantly influence any of the variables examined. Therefore, data from both ventilation modes were pooled for analysis. Mean arterial pressure, cardiac index, stroke index, rate-pressure product, left ventricular stroke work index, arterial and mixed-venous pH, PaO2, and oxygen delivery decreased, whereas PaCO2, PVO2, and mixed-venous partial pressure of CO2 increased significantly with increasing doses of sevoflurane. Noxious stimulation caused a significant increase in most cardiovascular variables. CONCLUSIONS AND CLINICAL RELEVANCE: Sevoflurane induces dose-dependent cardiovascular depression in cats that is mainly attributable to myocardial depression.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 14719697     DOI: 10.2460/ajvr.2004.65.20

Source DB:  PubMed          Journal:  Am J Vet Res        ISSN: 0002-9645            Impact factor:   1.156


  1 in total

Review 1.  Non-invasive blood pressure measurement in animals: Part 1 - Techniques for measurement and validation of non-invasive devices.

Authors:  Alicia Skelding; Alexander Valverde
Journal:  Can Vet J       Date:  2020-04       Impact factor: 1.008

  1 in total