Literature DB >> 3209777

Erratum: transient pulsations of small gas bubbles in water [J. Acoust. Soc. Am. 84, 985-998 (1988)] [corrected and republished].

H G Flynn1, C C Church.   

Abstract

Transient behavior of small gas bubbles in a liquid set into violent motion by ultrasonic pressure waves is of interest because of widespread use of microsecond pulses in diagnostic ultrasound. Such pulses contain only a few pressure cycles and the transient pulsations of bubbles set in motion by such pulses would determine the bubble-ultrasound interaction. A computer study has been made to obtain a global representation of the pulsation amplitudes R (t) of small gas bubbles (nuclei) in water during the first few cycles of a cw ultrasonic pressure. One objective was to obtain a better understanding of cavitation phenomena where many nuclei with initial radii Rn from 0.1-20 microns are set in motion at pressures ranging from 0.5-5 bars and at frequencies from 0.5-10 MHz. Results allowed construction of surfaces showing the relative bubble amplitude R/Rn as a function of Rn and of the time t/TA, where TA is the acoustic period. One finding is that, in the range of peak pressures found in diagnostic pulses, transient cavities would be generated during the first pressure cycle from nuclei with initial radii as small as a few microns (micron). Nuclei that grow into transient cavities in the first pressure cycle are here called "prompt" nuclei. At a specified pressure, the size range of radii Rn in which they occur decreases with increasing frequency. At 5 bars, the range of Rn for prompt nuclei is 0.166-11.35 microns at 0.5 MHz and vanishes at 10 MHz.

Entities:  

Mesh:

Substances:

Year:  1988        PMID: 3209777     DOI: 10.1121/1.397253

Source DB:  PubMed          Journal:  J Acoust Soc Am        ISSN: 0001-4966            Impact factor:   1.840


  17 in total

Review 1.  Section 8--clinical relevance. American Institute of Ultrasound in Medicine.

Authors: 
Journal:  J Ultrasound Med       Date:  2000-02       Impact factor: 2.153

Review 2.  Section 6--mechanical bioeffects in the presence of gas-carrier ultrasound contrast agents. American Institute of Ultrasound in Medicine.

Authors: 
Journal:  J Ultrasound Med       Date:  2000-02       Impact factor: 2.153

Review 3.  Section 7--discussion of the mechanical index and other exposure parameters. American Institute of Ultrasound in Medicine.

Authors: 
Journal:  J Ultrasound Med       Date:  2000-02       Impact factor: 2.153

Review 4.  Section 4--bioeffects in tissues with gas bodies. American Institute of Ultrasound in Medicine.

Authors: 
Journal:  J Ultrasound Med       Date:  2000-02       Impact factor: 2.153

5.  Development of a theoretical model describing sonoporation activity of cells exposed to ultrasound in the presence of contrast agents.

Authors:  Monica M Forbes; William D O'Brien
Journal:  J Acoust Soc Am       Date:  2012-04       Impact factor: 1.840

6.  The role of cavitation in acoustically activated drug delivery.

Authors:  Ghaleb A Husseini; Mario A Diaz de la Rosa; Eric S Richardson; Douglas A Christensen; William G Pitt
Journal:  J Control Release       Date:  2005-10-03       Impact factor: 9.776

Review 7.  Ultrasound-biophysics mechanisms.

Authors:  William D O'Brien
Journal:  Prog Biophys Mol Biol       Date:  2006-08-08       Impact factor: 3.667

8.  Further investigation of the mechanism of Doxorubicin release from P105 micelles using kinetic models.

Authors:  Dana Stevenson-Abouelnasr; Ghaleb A Husseini; William G Pitt
Journal:  Colloids Surf B Biointerfaces       Date:  2006-11-16       Impact factor: 5.268

9.  Encapsulated contrast microbubble radial oscillation associated with postexcitation pressure peaks.

Authors:  M D Santin; D A King; J Foiret; A Haak; W D O'Brien; S L Bridal
Journal:  J Acoust Soc Am       Date:  2010-02       Impact factor: 1.840

10.  Examination of inertial cavitation of Optison in producing sonoporation of chinese hamster ovary cells.

Authors:  Monica M Forbes; Ryan L Steinberg; William D O'Brien
Journal:  Ultrasound Med Biol       Date:  2008-08-09       Impact factor: 2.998

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.