Literature DB >> 17120756

Application of multislice spiral CT for guidance of insertion of thoracic spine pedicle screws: an in vitro study.

Juan Wang1, Yicheng Zhou, Ning Hu, Renfa Wang.   

Abstract

To investigate the value of the guidance of three dimensional (3-D) reconstruction of multi-slice spiral CT (MSCT) for the placement of pedicle screws, the 3-D anatomical data of the thoracic pedicles were measured by MSCT in two embalmed human cadaveric thoracic pedicles spines (T1-T10) to guide the insertion of pedicle screws. After pulling the screws out, the pathways were filled with contrast media. The PW, PH, TSA and SSA of developed pathways were measured on the CT images and they were also measured on the real objects by caliper and goniometer. Analysis of variance demonstrated that the difference between the CT scans and real objects had no statistical significance (P > 0.05). Moreover, the difference between pedicle axis and developed pathway also had no statistical significance (P > 0.05). The data obtained from 3-D reconstruction of MSCT demonstrated that individualized standards, are not only accurate but also helpful for the successful placement of pedicle screws.

Entities:  

Mesh:

Year:  2006        PMID: 17120756     DOI: 10.1007/s11596-006-0429-3

Source DB:  PubMed          Journal:  J Huazhong Univ Sci Technolog Med Sci        ISSN: 1672-0733


  10 in total

1.  [Complications associated with the technique of pedicle screw fixation].

Authors:  Xi-sheng Weng; Gui-xing Qiu; Jia Zhang; Shu-gang Li; Xin-yu Yang; Yi-peng Wang; Jian-guo Zhang; Qi-bin Ye; Jin Lin; Ye Tian
Journal:  Zhongguo Yi Xue Ke Xue Yuan Xue Bao       Date:  2002-06

2.  Age-related variations in the horizontal and vertical diameters of the pedicles of the lumbar spine.

Authors:  H S Amonoo-Kuofi
Journal:  J Anat       Date:  1995-04       Impact factor: 2.610

3.  Placement of pedicle screws in the thoracic spine. Part II: An anatomical and radiographic assessment.

Authors:  A R Vaccaro; S J Rizzolo; R A Balderston; T J Allardyce; S R Garfin; C Dolinskas; H S An
Journal:  J Bone Joint Surg Am       Date:  1995-08       Impact factor: 5.284

4.  Projection of the thoracic pedicle and its morphometric analysis.

Authors:  N A Ebraheim; R Xu; M Ahmad; R A Yeasting
Journal:  Spine (Phila Pa 1976)       Date:  1997-02-01       Impact factor: 3.468

5.  Anatomic analysis of pedicle cortical and cancellous diameter as related to screw size.

Authors:  G R Misenhimer; R D Peek; L L Wiltse; S L Rothman; E H Widell
Journal:  Spine (Phila Pa 1976)       Date:  1989-04       Impact factor: 3.468

6.  Morphometry of the thoracic and lumbar spine related to transpedicular screw placement for surgical spinal fixation.

Authors:  M H Krag; D L Weaver; B D Beynnon; L D Haugh
Journal:  Spine (Phila Pa 1976)       Date:  1988-01       Impact factor: 3.468

7.  Spinal pedicle fixation: reliability and validity of roentgenogram-based assessment and surgical factors on successful screw placement.

Authors:  J N Weinstein; K F Spratt; D Spengler; C Brick; S Reid
Journal:  Spine (Phila Pa 1976)       Date:  1988-09       Impact factor: 3.468

8.  Preoperative CT determination of angles for sacral screw placement.

Authors:  B J Morse; N A Ebraheim; W T Jackson
Journal:  Spine (Phila Pa 1976)       Date:  1994-03-01       Impact factor: 3.468

9.  Accuracy of pedicle screw placement in lumbar fusions by plain radiographs and computed tomography.

Authors:  G L Farber; H M Place; R A Mazur; D E Jones; T R Damiano
Journal:  Spine (Phila Pa 1976)       Date:  1995-07-01       Impact factor: 3.468

10.  Placement of pedicle screws in the thoracic spine. Part I: Morphometric analysis of the thoracic vertebrae.

Authors:  A R Vaccaro; S J Rizzolo; T J Allardyce; M Ramsey; J Salvo; R A Balderston; J M Cotler
Journal:  J Bone Joint Surg Am       Date:  1995-08       Impact factor: 5.284

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.