Literature DB >> 31976041

Marginal and internal fit evaluation of conventional metal-ceramic versus zirconia CAD/CAM crowns.

Nayana Paul1, K N Raghavendra Swamy2, M R Dhakshaini3, Sanjukta Sowmya4, M B Ravi5.   

Abstract

BACKGROUND: The purpose of this in vivo study was to compare the marginal and internal gap widths of monolithic zirconia crowns fabricated by CAD/CAM technique and metal-ceramic crowns fabricated by conventional technique.
MATERIAL AND METHODS: 10 participants needing a single restoration were selected. Zirconia crowns using CAD/CAM technology (Group A) (n=10) and metal-ceramic crowns (Group B) (n=10) using lost wax casting technique were fabricated for each selected tooth. The marginal and internal gaps of crowns were recorded using a replica technique with light body silicone material stabilized with a regular set putty. Each replica was sectioned buccolingually and mesiodistally and then evaluated at five pre-determined sites. The points measured were PM for marginal gap, PA for axial gap, PAO for axio-occlusal transition gap and PO and PCO for occlusal gaps using a stereomicroscope at 30× magnification. The Paired Sample (t) test was used to detect significant differences between the two groups in terms of marginal and internal fit (α= 0.05).
RESULTS: The mean for the marginal gap was 77.42μm (±39.5μm) for Group A compared with 95.86μm (±55.12μm) for Group B. Mean values for internal gap was 87.24 (±21.7 µm) for Group A and 132.91 µm (± 50.63 µm) for Group B. Significant differences were observed between both the groups for marginal (p=.010) and internal (p=.000) fit.
CONCLUSIONS: The CAD/CAM fabricated zirconia crowns demonstrated a better accuracy of fit when compared to metal-ceramic crowns fabricated by conventional technology. Key words:Marginal fit, Internal fit, Computer-aided design/computer-aided manufacturing (CAD/CAM). Copyright:
© 2020 Medicina Oral S.L.

Entities:  

Year:  2020        PMID: 31976041      PMCID: PMC6969964          DOI: 10.4317/medoral.55946

Source DB:  PubMed          Journal:  J Clin Exp Dent        ISSN: 1989-5488


  24 in total

Review 1.  Fit of zirconia fixed partial denture: a systematic review.

Authors:  J Abduo; K Lyons; M Swain
Journal:  J Oral Rehabil       Date:  2010-11       Impact factor: 3.837

2.  In vitro study on marginal and internal fit of CAD/CAM all-ceramic crowns.

Authors:  Takashi Nakamura; Hideaki Tanaka; Soichiro Kinuta; Takeshi Akao; Kei Okamoto; Kazumichi Wakabayashi; Hirofumi Yatani
Journal:  Dent Mater J       Date:  2005-09       Impact factor: 2.102

3.  Marginal and internal fit of all-ceramic CAD/CAM crown-copings on chamfer preparations.

Authors:  A Bindl; W H Mörmann
Journal:  J Oral Rehabil       Date:  2005-06       Impact factor: 3.837

4.  Marginal accuracy of titanium copings fabricated by casting and CAD/CAM techniques.

Authors:  Siegbert Witkowski; Futoshi Komine; Thomas Gerds
Journal:  J Prosthet Dent       Date:  2006-07       Impact factor: 3.426

5.  Marginal and internal fits of fixed dental prostheses zirconia retainers.

Authors:  Florian Beuer; Hans Aggstaller; Daniel Edelhoff; Wolfgang Gernet; John Sorensen
Journal:  Dent Mater       Date:  2008-07-11       Impact factor: 5.304

6.  Marginal and internal fit of all-ceramic crowns fabricated with two different CAD/CAM systems.

Authors:  Kyu-Bok Lee; Charn-Woon Park; Kyo-Han Kim; Tae-Yub Kwon
Journal:  Dent Mater J       Date:  2008-05       Impact factor: 2.102

7.  The Marginal Fit of CAD/CAM Monolithic Ceramic and Metal-Ceramic Crowns.

Authors:  Yolanda Freire; Esther Gonzalo; Carlos Lopez-Suarez; Maria J Suarez
Journal:  J Prosthodont       Date:  2017-02-02       Impact factor: 2.752

8.  Precision of fit: zirconia three-unit fixed dental prostheses.

Authors:  Florian Beuer; Michael Naumann; Wolfgang Gernet; John A Sorensen
Journal:  Clin Oral Investig       Date:  2008-09-04       Impact factor: 3.573

Review 9.  Digital dentistry: an overview of recent developments for CAD/CAM generated restorations.

Authors:  F Beuer; J Schweiger; D Edelhoff
Journal:  Br Dent J       Date:  2008-05-10       Impact factor: 1.626

10.  Internal fit of single crowns produced by CAD-CAM and lost-wax metal casting technique assessed by the triple-scan protocol.

Authors:  Bjørn Einar Dahl; Hans Jacob Rønold; Jon E Dahl
Journal:  J Prosthet Dent       Date:  2016-09-28       Impact factor: 3.426

View more
  2 in total

1.  The Impact of Sintering Technology and Milling Technology on Fitting Titanium Crowns to Abutment Teeth-In Vitro Studies.

Authors:  Wojciech Ryniewicz; Łukasz Bojko; Anna M Ryniewicz
Journal:  Materials (Basel)       Date:  2022-08-24       Impact factor: 3.748

2.  Prospective Clinical Evaluation of Posterior Third-Generation Monolithic Zirconia Crowns Fabricated with Complete Digital Workflow: Two-Year Follow-Up.

Authors:  Mustafa Gseibat; Pablo Sevilla; Carlos Lopez-Suarez; Verónica Rodríguez; Jesús Peláez; María J Suárez
Journal:  Materials (Basel)       Date:  2022-01-17       Impact factor: 3.623

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.