Literature DB >> 18717171

Marginal and internal fit of all-ceramic crowns fabricated with two different CAD/CAM systems.

Kyu-Bok Lee1, Charn-Woon Park, Kyo-Han Kim, Tae-Yub Kwon.   

Abstract

This study evaluated the accuracy of marginal and internal fit between the all-ceramic crowns manufactured by a conventional double-layer computer-aided design/computer-aided manufacturing (CAD/CAM) system and a single-layer system. Ten standardized crowns were fabricated from each of these two systems: conventional double-layer CAD/CAM system (Procera) and a single-layer system (Cerec 3D). The copings and completed crowns were seated on the abutments by a special device that facilitated uniform loading, and the marginal discrepancies were measured. Internal gaps were also measured using a low-viscosity silicone material. Marginal discrepancies of Procera copings were significantly smaller than those of Procera crowns and Cerec 3D crowns (p < 0.05), but Procera crowns and Cerec 3D crowns did not differ significantly from each other (p > 0.05). On internal gaps, Cerec 3D crowns showed significantly larger internal gaps than Procera copings and crowns (p < 0.05). Within the limitations of this study, the single-layer system demonstrated acceptable marginal and internal fit.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18717171     DOI: 10.4012/dmj.27.422

Source DB:  PubMed          Journal:  Dent Mater J        ISSN: 0287-4547            Impact factor:   2.102


  25 in total

1.  An open CAM system for dentistry on the basis of China-made 5-axis simultaneous contouring CNC machine tool and industrial CAM software.

Authors:  Li Lu; Shusheng Liu; Shenggen Shi; Jianzhong Yang
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2011-10-25

2.  Influence of CAD/CAM zirconia for implant-abutment manufacturing on gingival fibroblasts and oral keratinocytes.

Authors:  A M Pabst; C Walter; A Bell; M Weyhrauch; I Schmidtmann; H Scheller; K M Lehmann
Journal:  Clin Oral Investig       Date:  2015-09-23       Impact factor: 3.573

3.  Influence of CAD/CAM all-ceramic materials on cell viability, migration ability and adenylate kinase release of human gingival fibroblasts and oral keratinocytes.

Authors:  A M Pabst; C Walter; L Grassmann; M Weyhrauch; D D Brüllmann; T Ziebart; H Scheller; K M Lehmann
Journal:  Clin Oral Investig       Date:  2013-08-31       Impact factor: 3.573

4.  Evaluation of the Marginal Fit of CAD/CAM Crowns Fabricated Using Two Different Chairside CAD/CAM Systems on Preparations of Varying Quality.

Authors:  Walter Renne; Bethany Wolf; Raymond Kessler; Karen McPherson; Anthony S Mennito
Journal:  J Esthet Restor Dent       Date:  2015-07-14       Impact factor: 2.843

5.  Effect of Resin Bonded Luting Agents Influencing Marginal Discrepancy in All Ceramic Complete Veneer Crowns.

Authors:  Dhanraj Ganapathy; Anusha Sathyamoorthy; Hemalatha Ranganathan; Karthikeyan Murthykumar
Journal:  J Clin Diagn Res       Date:  2016-12-01

6.  Accuracy of digital and conventional impression techniques and workflow.

Authors:  Paul Seelbach; Cora Brueckel; Bernd Wöstmann
Journal:  Clin Oral Investig       Date:  2012-10-21       Impact factor: 3.573

7.  Trueness of four different milling procedures used in dental CAD/CAM systems.

Authors:  Corinna Kirsch; Andreas Ender; Thomas Attin; Albert Mehl
Journal:  Clin Oral Investig       Date:  2016-07-28       Impact factor: 3.573

8.  In vitro fracture load of monolithic lithium disilicate ceramic molar crowns with different wall thicknesses.

Authors:  Bodo Seydler; Stefan Rues; Denise Müller; Marc Schmitter
Journal:  Clin Oral Investig       Date:  2013-08-01       Impact factor: 3.573

9.  Comparison of marginal adaptation and internal fit of monolithic lithium disilicate crowns produced by 4 different CAD/CAM systems.

Authors:  Brunna Mota Ferrairo; Fernanda Furtado Piras; Feranda Ferruzzi Lima; Heitor Marques Honório; Marco Antonio Hungaro Duarte; Ana Flávia Sanches Borges; José Henrique Rubo
Journal:  Clin Oral Investig       Date:  2020-08-11       Impact factor: 3.573

10.  Marginal and internal fit evaluation of conventional metal-ceramic versus zirconia CAD/CAM crowns.

Authors:  Nayana Paul; K N Raghavendra Swamy; M R Dhakshaini; Sanjukta Sowmya; M B Ravi
Journal:  J Clin Exp Dent       Date:  2020-01-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.