Literature DB >> 27692584

Internal fit of single crowns produced by CAD-CAM and lost-wax metal casting technique assessed by the triple-scan protocol.

Bjørn Einar Dahl1, Hans Jacob Rønold2, Jon E Dahl3.   

Abstract

STATEMENT OF PROBLEM: Whether single crowns produced by computer-aided design and computer-aided manufacturing (CAD-CAM) have an internal fit comparable to crowns made by lost-wax metal casting technique is unknown.
PURPOSE: The purpose of this in vitro study was to compare the internal fit of single crowns produced with the lost-wax and metal casting technique with that of single crowns produced with the CAD-CAM technique.
MATERIAL AND METHODS: The internal fit of 5 groups of single crowns produced with the CAD-CAM technique was compared with that of single crowns produced in cobalt-chromium with the conventional lost-wax and metal casting technique. Comparison was performed using the triple-scan protocol; scans of the master model, the crown on the master model, and the intaglio of the crown were superimposed and analyzed with computer software. The 5 groups were milled presintered zirconia, milled hot isostatic pressed zirconia, milled lithium disilicate, milled cobalt-chromium, and laser-sintered cobalt-chromium.
RESULTS: The cement space in both the mesiodistal and buccopalatal directions was statistically smaller (P<.05) for crowns made by the conventional lost-wax and metal casting technique compared with that of crowns produced by the CAD-CAM technique.
CONCLUSIONS: Single crowns made using the conventional lost-wax and metal casting technique have better internal fit than crowns produced using the CAD-CAM technique.
Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 27692584     DOI: 10.1016/j.prosdent.2016.06.017

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  7 in total

1.  Comparative Study of the Fit Accuracy of Full-Arch Bar Frameworks Fabricated with Different Presintered Cobalt-Chromium Alloys.

Authors:  Hang-Nga Mai; Tae-Yub Kwon; Min-Ho Hong; Du-Hyeong Lee
Journal:  Biomed Res Int       Date:  2018-08-05       Impact factor: 3.411

Review 2.  A systematic review on the accuracy of zirconia crowns and fixed dental prostheses.

Authors:  Per Svanborg
Journal:  Biomater Investig Dent       Date:  2020-01-07

Review 3.  Fit of tooth-supported zirconia single crowns-A systematic review of the literature.

Authors:  Walaa Magdy Ahmed; Batoul Shariati; Arwa Z Gazzaz; Mohammed E Sayed; Ricardo M Carvalho
Journal:  Clin Exp Dent Res       Date:  2020-09-03

4.  Comparison of internal fit of metal-ceramic crowns in CAD/CAM and lost-wax techniques in all fabrication stages through replica weighting, triple scanning, and scanning electron microscope.

Authors:  Sina Mohammadi Sadr; Elham Ahmadi; Masoumeh Hasani Tabatabaei; Saba Mohammadi; Faezeh Atri
Journal:  Clin Exp Dent Res       Date:  2022-02-20

5.  Marginal and internal fit evaluation of conventional metal-ceramic versus zirconia CAD/CAM crowns.

Authors:  Nayana Paul; K N Raghavendra Swamy; M R Dhakshaini; Sanjukta Sowmya; M B Ravi
Journal:  J Clin Exp Dent       Date:  2020-01-01

6.  Comparison of marginal and internal fit of three-unit implant-supported fixed prosthetic substructures fabricated using CAD/CAM systems.

Authors:  Ozlem Kayikci; Sabit Melih Ates
Journal:  Clin Oral Investig       Date:  2021-07-31       Impact factor: 3.573

Review 7.  A systematic review on the accuracy of manufacturing techniques for cobalt chromium fixed dental prostheses.

Authors:  Per Svanborg; Lars Hjalmarsson
Journal:  Biomater Investig Dent       Date:  2020-01-20
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.