Literature DB >> 11885679

A 30-MHz piezo-composite ultrasound array for medical imaging applications.

Timothy A Ritter1, Thomas R Shrout, Rick Tutwiler, K Kirk Shung.   

Abstract

Ultrasound imaging at frequencies above 20 MHz is capable of achieving improved resolution in clinical applications requiring limited penetration depth. High frequency arrays that allow real-time imaging are desired for these applications but are not yet currently available. In this work, a method for fabricating fine-scale 2-2 composites suitable for 30-MHz linear array transducers was successfully demonstrated. High thickness coupling, low mechanical loss, and moderate electrical loss were achieved. This piezo-composite was incorporated into a 30-MHz array that included acoustic matching, an elevation focusing lens, electrical matching, and an air-filled kerf between elements. Bandwidths near 60%, 15-dB insertion loss, and crosstalk less than -30 dB were measured. Images of both a phantom and an ex vivo human eye were acquired using a synthetic aperture reconstruction method, resulting in measured lateral and axial resolutions of approximately 100 microm.

Entities:  

Mesh:

Year:  2002        PMID: 11885679     DOI: 10.1109/58.985706

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  30 in total

1.  Automated skin segmentation in ultrasonic evaluation of skin toxicity in breast cancer radiotherapy.

Authors:  Yi Gao; Allen Tannenbaum; Hao Chen; Mylin Torres; Emi Yoshida; Xiaofeng Yang; Yuefeng Wang; Walter Curran; Tian Liu
Journal:  Ultrasound Med Biol       Date:  2013-08-27       Impact factor: 2.998

2.  40-MHz annular array imaging of mouse embryos.

Authors:  Orlando Aristizábal; Jeffrey A Ketterling; Daniel H Turnbull
Journal:  Ultrasound Med Biol       Date:  2006-11       Impact factor: 2.998

3.  High-frequency ultrasound Doppler system for biomedical applications with a 30-MHz linear array.

Authors:  Xiaochen Xu; Lei Sun; Jonathan M Cannata; Jesse T Yen; K Kirk Shung
Journal:  Ultrasound Med Biol       Date:  2007-11-12       Impact factor: 2.998

4.  Improved high-resolution ultrasonic imaging of the eye.

Authors:  Ronald H Silverman; Jeffrey A Ketterling; Jonathan Mamou; D Jackson Coleman
Journal:  Arch Ophthalmol       Date:  2008-01

5.  Design and implementation of high frequency ultrasound pulsed-wave Doppler using FPGA.

Authors:  Chang-hong Hu; Qifa Zhou; K Kirk Shung
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2008-09       Impact factor: 2.725

6.  Piezoelectric single crystals for ultrasonic transducers in biomedical applications.

Authors:  Qifa Zhou; Kwok Ho Lam; Hairong Zheng; Weibao Qiu; K Kirk Shung
Journal:  Prog Mater Sci       Date:  2014-10-01

7.  Optimization of Contrast-to-Tissue Ratio Through Pulse Windowing in Dual-Frequency "Acoustic Angiography" Imaging.

Authors:  Brooks D Lindsey; Sarah E Shelton; Paul A Dayton
Journal:  Ultrasound Med Biol       Date:  2015-03-25       Impact factor: 2.998

8.  Design and fabrication of a 40-MHz annular array transducer.

Authors:  Jeffrey A Ketterling; Orlando Aristizábal; Daniel H Turnbull; Frederic L Lizzi
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2005-04       Impact factor: 2.725

9.  A Dual-Frequency Colinear Array for Acoustic Angiography in Prostate Cancer Evaluation.

Authors:  Sibo Li; Jinwook Kim; Zhuochen Wang; Sandeep Kasoji; Brooks D Lindsey; Paul A Dayton; Xiaoning Jiang
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-10-01       Impact factor: 2.725

10.  Characterization of a broadband all-optical ultrasound transducer-from optical and acoustical properties to imaging.

Authors:  Yang Hou; Jin-Sung Kim; Sheng-Wen Huang; S Ashkenazi; L J Guo; M O'Donnell
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2008-08       Impact factor: 2.725

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.