Literature DB >> 18267647

Efficient synthetic aperture imaging from a circular aperture with possible application to catheter-based imaging.

M O'Donnell1, L J Thomas.   

Abstract

Phased-array imaging, including complete dynamic focus, is explored for imaging using a circular aperture. Based on the constraints of catheter-based systems, an efficient synthetic aperture method has been developed for imaging using a single wire connection between the imaging array and external electronics. The method employs a highly sampled array with an element pitch small compared to the acoustic wavelength. On any given firing of the array, however, a large number of channels are electrically connected on both transmission and reception. From firing to firing, one element is dropped and one new element is included, in analogy to a classic linear array system. Using an optimal filtering approach for synthetic aperture reconstruction, a dynamically focused image exhibiting diffraction limited resolution is produced. The results of detailed simulations are presented demonstrating the capabilities of the method. In addition, the prospects for real-time implementation of the reconstruction are discussed.

Year:  1992        PMID: 18267647     DOI: 10.1109/58.143171

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  11 in total

1.  Thermal strain imaging: a review.

Authors:  Chi Hyung Seo; Yan Shi; Sheng-Wen Huang; Kang Kim; Matthew O'Donnell
Journal:  Interface Focus       Date:  2011-05-23       Impact factor: 3.906

2.  Optimizing circular ring arrays for forward-looking IVUS imaging.

Authors:  Coskun Tekes; Mustafa Karaman; F Levent Degertekin
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2011-12       Impact factor: 2.725

3.  High-frame-rate echocardiography using diverging transmit beams and parallel receive beamforming.

Authors:  Hideyuki Hasegawa; Hiroshi Kanai
Journal:  J Med Ultrason (2001)       Date:  2011-05-07       Impact factor: 1.314

4.  Impact of element pitch on synthetic aperture ultrasound imaging.

Authors:  Hideyuki Hasegawa; Chris L de Korte
Journal:  J Med Ultrason (2001)       Date:  2016-02-20       Impact factor: 1.314

5.  Intravascular Ultrasound Imaging With Virtual Source Synthetic Aperture Focusing and Coherence Factor Weighting.

Authors:  Mingyue Yu; Yang Li; Teng Ma; K Kirk Shung; Qifa Zhou
Journal:  IEEE Trans Med Imaging       Date:  2017-07-04       Impact factor: 10.048

6.  An Impulse Radio PWM-Based Wireless Data Acquisition Sensor Interface.

Authors:  Jaemyung Lim; Ahmad Rezvanitabar; F Levent Degertekin; Maysam Ghovanloo
Journal:  IEEE Sens J       Date:  2018-10-29       Impact factor: 3.301

7.  A method for direct localized sound speed estimates using registered virtual detectors.

Authors:  Brett C Byram; Gregg E Trahey; Jørgen A Jensen
Journal:  Ultrason Imaging       Date:  2012-07       Impact factor: 1.578

8.  Noninvasive estimation of local speed of sound by pulse-echo ultrasound in a rat model of nonalcoholic fatty liver.

Authors:  Arsenii V Telichko; Rehman Ali; Thurston Brevett; Huaijun Wang; Jose G Vilches-Moure; Sukumar U Kumar; Ramasamy Paulmurugan; Jeremy J Dahl
Journal:  Phys Med Biol       Date:  2022-01-17       Impact factor: 3.609

9.  Towards a Reduced-Wire Interface for CMUT-Based Intravascular Ultrasound Imaging Systems.

Authors:  Jaemyung Lim; Coskun Tekes; F Levent Degertekin; Maysam Ghovanloo
Journal:  IEEE Trans Biomed Circuits Syst       Date:  2016-09-20       Impact factor: 3.833

10.  A Micromachined Pb(Mg1/3Nb2/3)O3-PbTiO3 Single Crystal Composite Circular Array for Intravascular Ultrasound Imaging.

Authors:  Sibo Li; Jian Tian; Xiaoning Jiang
Journal:  J Eng Sci Med Diagn Ther       Date:  2019-01-18