Literature DB >> 31867235

Body coil reference for inverse reconstructions of multi-coil data-the case for real-time MRI.

Dirk Voit1, Oleksandr Kalentev1, Jens Frahm1.   

Abstract

Real-time magnetic resonance imaging (MRI) or model-based MRI reconstructions of parametric maps require the solution of an ill-posed nonlinear inverse problem. Respective algorithms, e.g., the iteratively regularized Gauss-Newton method, implicitly combine datasets from multiple receive coils. Because these local coils may exhibit complex sensitivity profiles with rather different phase offsets, the numerical optimization may lead to phase singularities which in turn cause "black holes" in magnitude images. The purpose of this work is to develop a method for inverse reconstructions of multi-coil MRI data which avoids the generation of such spatially selective phase singularities. It is proposed to use volumetric body coil data and start the iterative reconstruction of multi-coil data with a reference image which offers proper phase information. In more detail, inverse reconstructions of multi-coil data are initialized with a complex "seed" image which is obtained by a Fast Fourier Transform (FFT) reconstruction of data from a single body coil element. This is accomplished at no additional cost as only very few body coil scans with identical conditions as the multi-coil acquisitions are needed as part of the regular prep scan period. The method is evaluated for anatomical real-time MRI and model-based phase-contrast flow MRI in real-time at 3 T. The proposed method overcomes phase singularities in all cases for arbitrary sets of receive coils. In conclusion, the automatic use of a single body coil reference image is simple, robust, and further improves the reliability of advanced MRI reconstructions from multi-coil data. 2019 Quantitative Imaging in Medicine and Surgery. All rights reserved.

Keywords:  Black hole; iterative optimization; nonlinear inverse reconstruction; phase singularity; real-time magnetic resonance imaging (real-time MRI)

Year:  2019        PMID: 31867235      PMCID: PMC6902137          DOI: 10.21037/qims.2019.08.14

Source DB:  PubMed          Journal:  Quant Imaging Med Surg        ISSN: 2223-4306


  11 in total

1.  Adaptive reconstruction of phased array MR imagery.

Authors:  D O Walsh; A F Gmitro; M W Marcellin
Journal:  Magn Reson Med       Date:  2000-05       Impact factor: 4.668

2.  Combination of signals from array coils using image-based estimation of coil sensitivity profiles.

Authors:  M Bydder; D J Larkman; J V Hajnal
Journal:  Magn Reson Med       Date:  2002-03       Impact factor: 4.668

3.  Real-time phase-contrast MRI of cardiovascular blood flow using undersampled radial fast low-angle shot and nonlinear inverse reconstruction.

Authors:  Arun A Joseph; Klaus-Dietmar Merboldt; Dirk Voit; Shuo Zhang; Martin Uecker; Joachim Lotz; Jens Frahm
Journal:  NMR Biomed       Date:  2011-12-19       Impact factor: 4.044

4.  The NMR phased array.

Authors:  P B Roemer; W A Edelstein; C E Hayes; S P Souza; O M Mueller
Journal:  Magn Reson Med       Date:  1990-11       Impact factor: 4.668

5.  Real-time MRI at a resolution of 20 ms.

Authors:  Martin Uecker; Shuo Zhang; Dirk Voit; Alexander Karaus; Klaus-Dietmar Merboldt; Jens Frahm
Journal:  NMR Biomed       Date:  2010-10       Impact factor: 4.044

6.  Selective channel combination of MRI signal phase.

Authors:  Viktor Vegh; Kieran O'Brien; Markus Barth; David C Reutens
Journal:  Magn Reson Med       Date:  2015-11-24       Impact factor: 4.668

7.  An eigenvalue approach for the automatic scaling of unknowns in model-based reconstructions: Application to real-time phase-contrast flow MRI.

Authors:  Zhengguo Tan; Thorsten Hohage; Oleksandr Kalentev; Arun A Joseph; Xiaoqing Wang; Dirk Voit; K Dietmar Merboldt; Jens Frahm
Journal:  NMR Biomed       Date:  2017-09-28       Impact factor: 4.044

8.  Phase reconstruction from multiple coil data using a virtual reference coil.

Authors:  Dennis L Parker; Allison Payne; Nick Todd; J Rock Hadley
Journal:  Magn Reson Med       Date:  2013-09-04       Impact factor: 4.668

9.  Model-based reconstruction for real-time phase-contrast flow MRI: Improved spatiotemporal accuracy.

Authors:  Zhengguo Tan; Volkert Roeloffs; Dirk Voit; Arun A Joseph; Markus Untenberger; K Dietmar Merboldt; Jens Frahm
Journal:  Magn Reson Med       Date:  2016-03-07       Impact factor: 4.668

10.  Combining phase images from array coils using a short echo time reference scan (COMPOSER).

Authors:  Simon Daniel Robinson; Barbara Dymerska; Wolfgang Bogner; Markus Barth; Olgica Zaric; Sigrun Goluch; Günther Grabner; Xeni Deligianni; Oliver Bieri; Siegfried Trattnig
Journal:  Magn Reson Med       Date:  2015-12-29       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.