Literature DB >> 20799371

Real-time MRI at a resolution of 20 ms.

Martin Uecker1, Shuo Zhang, Dirk Voit, Alexander Karaus, Klaus-Dietmar Merboldt, Jens Frahm.   

Abstract

The desire to visualize noninvasively physiological processes at high temporal resolution has been a driving force for the development of MRI since its inception in 1973. In this article, we describe a unique method for real-time MRI that reduces image acquisition times to only 20 ms. Although approaching the ultimate limit of MRI technology, the method yields high image quality in terms of spatial resolution, signal-to-noise ratio and the absence of artifacts. As proposed previously, a fast low-angle shot (FLASH) gradient-echo MRI technique (which allows for rapid and continuous image acquisitions) is combined with a radial encoding scheme (which offers motion robustness and moderate tolerance to data undersampling) and, most importantly, an iterative image reconstruction by regularized nonlinear inversion (which exploits the advantages of parallel imaging with multiple receiver coils). In this article, the extension of regularization and filtering to the temporal domain exploits consistencies in successive data acquisitions and thereby enhances the degree of radial undersampling in a hitherto unexpected manner by one order of magnitude. The results obtained for turbulent flow, human speech production and human heart function demonstrate considerable potential for real-time MRI studies of dynamic processes in a wide range of scientific and clinical settings.
Copyright © 2010 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Year:  2010        PMID: 20799371     DOI: 10.1002/nbm.1585

Source DB:  PubMed          Journal:  NMR Biomed        ISSN: 0952-3480            Impact factor:   4.044


  87 in total

Review 1.  Real-time magnetic resonance imaging of cardiac function and flow-recent progress.

Authors:  Shuo Zhang; Arun A Joseph; Dirk Voit; Sebastian Schaetz; Klaus-Dietmar Merboldt; Christina Unterberg-Buchwald; Anja Hennemuth; Joachim Lotz; Jens Frahm
Journal:  Quant Imaging Med Surg       Date:  2014-10

2.  Magnetic resonance imaging compatible remote catheter navigation system with 3 degrees of freedom.

Authors:  M A Tavallaei; M K Lavdas; D Gelman; M Drangova
Journal:  Int J Comput Assist Radiol Surg       Date:  2015-12-24       Impact factor: 2.924

3.  Peak flow velocities in the ascending aorta-real-time phase-contrast magnetic resonance imaging vs. cine magnetic resonance imaging and echocardiography.

Authors:  Jan M Sohns; Johannes T Kowallick; Arun A Joseph; K Dietmar Merboldt; Dirk Voit; Martin Fasshauer; Wieland Staab; Jens Frahm; Joachim Lotz; Christina Unterberg-Buchwald
Journal:  Quant Imaging Med Surg       Date:  2015-10

Review 4.  Principles and methods for automatic and semi-automatic tissue segmentation in MRI data.

Authors:  Lei Wang; Teodora Chitiboi; Hans Meine; Matthias Günther; Horst K Hahn
Journal:  MAGMA       Date:  2016-01-11       Impact factor: 2.310

5.  Real-time MRI for the dynamic assessment of fundoplication failure in patients with gastroesophageal reflux disease.

Authors:  Ali Seif Amir Hosseini; Johannes Uhlig; Ulrike Streit; Dirk Voit; Annemarie Uhlig; Volker Ellenrieder; Michael Ghadimi; Thilo Sprenger; Alexander Beham; Martin Uecker; Jens Frahm; Joachim Lotz; Lorenz Biggemann
Journal:  Eur Radiol       Date:  2019-02-25       Impact factor: 5.315

Review 6.  Recommendations for real-time speech MRI.

Authors:  Sajan Goud Lingala; Brad P Sutton; Marc E Miquel; Krishna S Nayak
Journal:  J Magn Reson Imaging       Date:  2015-07-14       Impact factor: 4.813

7.  High-speed real-time magnetic resonance imaging of fast tongue movements in elite horn players.

Authors:  Peter W Iltis; Jens Frahm; Dirk Voit; Arun A Joseph; Erwin Schoonderwaldt; Eckart Altenmüller
Journal:  Quant Imaging Med Surg       Date:  2015-06

Review 8.  The emerging potential of magnetic resonance imaging in personalizing radiotherapy for head and neck cancer: an oncologist's perspective.

Authors:  Kee H Wong; Rafal Panek; Shreerang A Bhide; Christopher M Nutting; Kevin J Harrington; Katie L Newbold
Journal:  Br J Radiol       Date:  2017-03       Impact factor: 3.039

9.  Self-gated MRI of multiple beat morphologies in the presence of arrhythmias.

Authors:  Francisco Contijoch; Srikant Kamesh Iyer; James J Pilla; Paul Yushkevich; Joseph H Gorman; Robert C Gorman; Harold Litt; Yuchi Han; Walter R T Witschey
Journal:  Magn Reson Med       Date:  2016-08-31       Impact factor: 4.668

10.  In vivo magnetic resonance imaging and spectroscopy. Technological advances and opportunities for applications continue to abound.

Authors:  Peter van Zijl; Linda Knutsson
Journal:  J Magn Reson       Date:  2019-07-09       Impact factor: 2.229

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.