| Literature DB >> 31764091 |
L J W Bosch1, V Melotte2, S Mongera3, K L J Daenen2, V M H Coupé4, S T van Turenhout5, E M Stoop6, T R de Wijkerslooth7, C J J Mulder5, C Rausch1, E J Kuipers6, E Dekker7, M J Domanico8, G P Lidgard8, B M Berger8, M van Engeland2, B Carvalho1, G A Meijer1.
Abstract
INTRODUCTION: We set out to evaluate the performance of a multitarget stool DNA (MT-sDNA) in an average-risk colonoscopy-controlled colorectal cancer (CRC) screening population. MT-sDNA stool test results were evaluated against fecal immunochemical test (FIT) results for the detection of different lesions, including molecularly defined high-risk adenomas and several other tumor characteristics.Entities:
Mesh:
Substances:
Year: 2019 PMID: 31764091 PMCID: PMC6903367 DOI: 10.14309/ajg.0000000000000445
Source DB: PubMed Journal: Am J Gastroenterol ISSN: 0002-9270 Impact factor: 10.864
Figure 1.Flowchart of the study design. The upper part indicates the stool collection derived from the colonoscopy arm of individuals who participated the COCOS trial. Only individuals who had a complete colonoscopy, who had a valid FIT result, and who provided a whole stool sample were included in the biomarker study population. Tissues were collected from participants with an advanced neoplasia, e.g., CRC, AA, and/or ASP, of which the numbers and performed analyses are indicated in the lower part. AA, advanced adenoma; ASP, advanced serrated polyp; COCOS, COlonoscopy or COlonography for Screening; CRC, colorectal cancer.
Figure 2.Boxplots showing sDNA test values in the COCOS biomarker population. Boxplots show first quartile, median, third quartile, and range of sDNA test values. Dots represent individual data points. The horizontal dashed lines indicate the predefined threshold for a positive test results as reported before (*) [ref Imperiale et al., NEJM, 2014], and the adapter threshold as defined in the current study using a fixed specificity of 95%. COCOS, COlonoscopy or COlonography for Screening.
Sensitivity and specificity at predefined cutoffs for the MT-sDNA test (threshold 183) and FIT (threshold 50, 75, and 100)
Figure 3.Receiver operating characteristic (ROC) curves of the sDNA test vs FIT on advanced precancerous lesions (a) subdivided into advanced adenoma (b) and advanced serrated polyps (c). The continuous and dashed lines in the ROC curves show the performance of sDNA and FIT, respectively. AUC, area under the curve; FIT, fecal immunochemical test.
Sensitivity and specificity at equal fixed specificity of 95%
Stool test results in relation to different tumor characteristics