Christoph Aberle1, Nick Ryckx2, Reto Treier3, Sebastian Schindera4. 1. Department of Radiology, University Hospital Basel, University of Basel, Petersgraben 4, 4031, Basel, Switzerland. christoph.aberle@usb.ch. 2. Department of Diagnostic and Interventional Radiology, Lausanne University Hospital, Lausanne, Switzerland. 3. Radiation Protection Division, Federal Office of Public Health, Bern, Switzerland. 4. Institute of Radiology, Cantonal Hospital of Aarau, Aarau, Switzerland.
Abstract
OBJECTIVES: To update the national diagnostic reference levels (DRLs) for adult CT in Switzerland using dose management software and to compare them to the previous Swiss DRLs from 2010. METHODS: CT dose data from 14 radiological institutes with a total of 50 CT scanners were collected with locally installed dose management software between 2014 and 2017. Data were assigned to 15 defined master protocols. Data cleaning steps were developed and adjusted individually for each participating institute and protocol. The DRLs for each master protocol were calculated as the 75th percentile of the distribution of the median volume computed tomography dose index (CTDIvol) and dose-length product (DLP) values per CT scanner. RESULTS: In total, 220,269 CT exams were available after data cleaning. Updated DRLs showed a clear trend towards lower doses compared with previous DRLs. The average relative change in the DRLs for CTDIvol was - 30% (0 to - 47%) and - 22% for DLP (+ 20 to - 40%). The largest relative decrease in the DRL for DLP was observed for the cervical spine protocol (- 40%), the two chest protocols (chest, - 37%; and exclusion of pulmonary embolism, - 33%), and the two neck protocols (neck, - 32%; and carotid angiography, - 28%). The DRLs for other protocols, for example the head and the abdomen-pelvis protocol, showed smaller relative changes (- 11% and - 17%). CONCLUSIONS: The updated national DRLs are substantially lower than the previous values from 2010, demonstrating technological progress and the efforts of the radiological community to lower CT radiation exposure. KEY POINTS: • Dose management software allows the establishment of DRLs based on big data. • Updated Swiss DRLs for adult CT are substantially lower compared with those from 2010. • Swiss DRLs are low compared with other national DRLs.
OBJECTIVES: To update the national diagnostic reference levels (DRLs) for adult CT in Switzerland using dose management software and to compare them to the previous Swiss DRLs from 2010. METHODS: CT dose data from 14 radiological institutes with a total of 50 CT scanners were collected with locally installed dose management software between 2014 and 2017. Data were assigned to 15 defined master protocols. Data cleaning steps were developed and adjusted individually for each participating institute and protocol. The DRLs for each master protocol were calculated as the 75th percentile of the distribution of the median volume computed tomography dose index (CTDIvol) and dose-length product (DLP) values per CT scanner. RESULTS: In total, 220,269 CT exams were available after data cleaning. Updated DRLs showed a clear trend towards lower doses compared with previous DRLs. The average relative change in the DRLs for CTDIvol was - 30% (0 to - 47%) and - 22% for DLP (+ 20 to - 40%). The largest relative decrease in the DRL for DLP was observed for the cervical spine protocol (- 40%), the two chest protocols (chest, - 37%; and exclusion of pulmonary embolism, - 33%), and the two neck protocols (neck, - 32%; and carotid angiography, - 28%). The DRLs for other protocols, for example the head and the abdomen-pelvis protocol, showed smaller relative changes (- 11% and - 17%). CONCLUSIONS: The updated national DRLs are substantially lower than the previous values from 2010, demonstrating technological progress and the efforts of the radiological community to lower CT radiation exposure. KEY POINTS: • Dose management software allows the establishment of DRLs based on big data. • Updated Swiss DRLs for adult CT are substantially lower compared with those from 2010. • Swiss DRLs are low compared with other national DRLs.
Authors: Eleni Theano Samara; Abbas Aroua; François O Bochud; Barbara Ott; Thomas Theiler; Reto Treier; Philipp R Trueb; John-Paul Vader; Francis R Verdun Journal: Health Phys Date: 2012-03 Impact factor: 1.316
Authors: Kalpana M Kanal; Priscilla F Butler; Debapriya Sengupta; Mythreyi Bhargavan-Chatfield; Laura P Coombs; Richard L Morin Journal: Radiology Date: 2017-02-21 Impact factor: 11.105
Authors: Johannes Boos; Rotem S Lanzman; Philipp Heusch; Joel Aissa; Christoph Schleich; Christoph Thomas; Lino M Sawicki; Gerald Antoch; Patric Kröpil Journal: Br J Radiol Date: 2015-12-23 Impact factor: 3.039
Authors: Denis Tack; Jacques Widelec; Viviane De Maertelaer; Jean-Marie Bailly; Christian Delcour; Pierre Alain Gevenois Journal: AJR Am J Roentgenol Date: 2003-10 Impact factor: 3.959
Authors: Régis Le Coultre; Julie Bize; Mélanie Champendal; David Wittwer; Nick Ryckx; Abbas Aroua; Philipp Trueb; Francis R Verdun Journal: Radiat Prot Dosimetry Date: 2015-11-04 Impact factor: 0.972
Authors: Rebecca Smith-Bindman; Yifei Wang; Philip Chu; Robert Chung; Andrew J Einstein; Jonathan Balcombe; Mary Cocker; Marcos Das; Bradley N Delman; Michael Flynn; Robert Gould; Ryan K Lee; Thomas Yellen-Nelson; Sebastian Schindera; Anthony Seibert; Jay Starkey; Saravanabavaan Suntharalingam; Axel Wetter; Joachim E Wildberger; Diana L Miglioretti Journal: BMJ Date: 2019-01-02
Authors: Denise Bos; Sophronia Yu; Jason Luong; Philip Chu; Yifei Wang; Andrew J Einstein; Jay Starkey; Bradley N Delman; Phuong-Anh T Duong; Marco Das; Sebastian Schindera; Allen R Goode; Fiona MacLeod; Axel Wetter; Rebecca Neill; Ryan K Lee; Jodi Roehm; James A Seibert; Luisa F Cervantes; Nima Kasraie; Pavlina Pike; Anokh Pahwa; Cécile R L P N Jeukens; Rebecca Smith-Bindman Journal: Eur Radiol Date: 2021-10-13 Impact factor: 5.315
Authors: Elena Tonkopi; Eline Jahre Wikan; Tor Olav Hovland; Sivert Høgset; Thomas Alexander Kofod; Selasi K Sefenu; Emily Hughes-Ryan; Dakota D Entremont-O Connell; Catherine Gunn; Tanja Holter; Safora Johansen Journal: Acta Radiol Open Date: 2022-10-07
Authors: Anaïs Viry; Christoph Aberle; Thiago Lima; Reto Treier; Sebastian T Schindera; Francis R Verdun; Damien Racine Journal: Eur Radiol Date: 2021-07-29 Impact factor: 5.315