Literature DB >> 14500205

Comparison between low-dose and standard-dose multidetector CT in patients with suspected chronic sinusitis.

Denis Tack1, Jacques Widelec, Viviane De Maertelaer, Jean-Marie Bailly, Christian Delcour, Pierre Alain Gevenois.   

Abstract

OBJECTIVE: This study was designed to compare low- and standard-dose multidetector CT (MDCT) findings in patients with suspected chronic sinusitis. SUBJECTS AND METHODS. Fifty patients underwent MDCT at 10 and 150 effective mAs. The low-dose MDCT protocol delivered a radiation dose of 0.047 mSv in men and 0.051 mSv in women, whereas the standard-dose MDCT protocol delivered a radiation dose of 0.70 mSv in men and 0.76 mSv in women. Scans of the right and left sides of sinonasal cavities were reviewed by three radiologists, with each physician reviewing a scan twice over an interval of more than 2 weeks. The reviewers were asked to evaluate the scans for eight mucosal and two bone abnormalities. We calculated the number of discrepancies in observed abnormalities between pairs of reviewers, among all three reviewers, and between findings on scans acquired with the two radiation doses.
RESULTS: The mean number of discrepancies in observed abnormalities on scans acquired with different radiation doses ranged from 0 to 5.2. Discrepancies between pairs of reviewers ranged from 1.0 to 12.8 for low-dose scans and from 1.0 to 13.0 for standard-dose scans. Discrepancies among all reviewers ranged from 1.0 to 10.3 for low-dose scans and from 1.0 to 8.7 for standard-dose scans. In analyzing cases of significant discrepancies in observations, we found greater variation between pairs of reviewers and among all three reviewers than between findings obtained with different dose levels.
CONCLUSION: Dose reduction played a far less important role in discrepancies of detected abnormalities than did the human element of reviewer observation. Given this finding and the fact that low-dose MDCT delivers a radiation dose that is no higher than that delivered by a four-view radiographic examination, low-dose MDCT should be considered the imaging method of choice in patients with suspected chronic sinusitis.

Entities:  

Mesh:

Year:  2003        PMID: 14500205     DOI: 10.2214/ajr.181.4.1810939

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  21 in total

Review 1.  [Radiological diagnosis of the paranasal sinuses].

Authors:  M Cohnen
Journal:  Radiologe       Date:  2010-03       Impact factor: 0.635

Review 2.  Advances in imaging of the paranasal sinuses.

Authors:  Francis T K Ling; Stilianos E Kountakis
Journal:  Curr Allergy Asthma Rep       Date:  2006-11       Impact factor: 4.806

3.  Low-Dose CT of the Paranasal Sinuses: Minimizing X-Ray Exposure with Spectral Shaping.

Authors:  Wolfgang Wuest; Matthias May; Marc Saake; Michael Brand; Michael Uder; Michael Lell
Journal:  Eur Radiol       Date:  2016-02-24       Impact factor: 5.315

Review 4.  Preoperative imaging procedures for lower wisdom teeth removal.

Authors:  Lennart Flygare; Anders Ohman
Journal:  Clin Oral Investig       Date:  2008-04-30       Impact factor: 3.573

5.  Comparison of whole-body 64-slice multidetector computed tomography and conventional radiography in staging of multiple myeloma.

Authors:  Patric Kröpil; Roland Fenk; Lars B Fritz; Dirk Blondin; Guido Kobbe; Ulrich Mödder; Mathias Cohnen
Journal:  Eur Radiol       Date:  2007-10-09       Impact factor: 5.315

6.  Evaluation of different low-dose multidetector CT and cone beam CT protocols in maxillary sinus imaging: part I-an in vitro study.

Authors:  Abeer A Almashraqi; Eman A Ahmed; Nashwa S Mohamed; Imad H Barngkgei; Nader A Elsherbini; Esam S Halboub
Journal:  Dentomaxillofac Radiol       Date:  2017-04-12       Impact factor: 2.419

7.  Imaging the Parasinus Region with a Third-Generation Dual-Source CT and the Effect of Tin Filtration on Image Quality and Radiation Dose.

Authors:  M M Lell; M S May; M Brand; A Eller; T Buder; E Hofmann; M Uder; W Wuest
Journal:  AJNR Am J Neuroradiol       Date:  2015-03-26       Impact factor: 3.825

8.  Radiation dose reduction in paranasal sinus CT using model-based iterative reconstruction.

Authors:  J M Hoxworth; D Lal; G P Fletcher; A C Patel; M He; R G Paden; A K Hara
Journal:  AJNR Am J Neuroradiol       Date:  2013-10-10       Impact factor: 3.825

9.  Dental flat panel conebeam CT in the evaluation of patients with inflammatory sinonasal disease: Diagnostic efficacy and radiation dose savings.

Authors:  C Leiva-Salinas; L Flors; P Gras; F Más-Estellés; P Lemercier; J T Patrie; M Wintermark; L Martí-Bonmatí
Journal:  AJNR Am J Neuroradiol       Date:  2014-06-26       Impact factor: 3.825

10.  Update of national diagnostic reference levels for adult CT in Switzerland and assessment of radiation dose reduction since 2010.

Authors:  Christoph Aberle; Nick Ryckx; Reto Treier; Sebastian Schindera
Journal:  Eur Radiol       Date:  2019-11-20       Impact factor: 5.315

View more