Literature DB >> 29808427

National survey on dose data analysis in computed tomography.

Christina Heilmaier1, Reto Treier2, Elmar Max Merkle3,4, Hatem Alkadhi3,5, Dominik Weishaupt3,6, Sebastian Schindera3,7.   

Abstract

OBJECTIVES: A nationwide survey was performed assessing current practice of dose data analysis in computed tomography (CT).
MATERIAL AND METHODS: All radiological departments in Switzerland were asked to participate in the on-line survey composed of 19 questions (16 multiple choice, 3 free text). It consisted of four sections: (1) general information on the department, (2) dose data analysis, (3) use of a dose management software (DMS) and (4) radiation protection activities.
RESULTS: In total, 152 out of 241 Swiss radiological departments filled in the whole questionnaire (return rate, 63%). Seventy-nine per cent of the departments (n = 120/152) analyse dose data on a regular basis with considerable heterogeneity in the frequency (1-2 times per year, 45%, n = 54/120; every month, 35%, n = 42/120) and method of analysis. Manual analysis is carried out by 58% (n = 70/120) compared with 42% (n = 50/120) of departments using a DMS. Purchase of a DMS is planned by 43% (n = 30/70) of the departments with manual analysis. Real-time analysis of dose data is performed by 42% (n = 21/50) of the departments with a DMS; however, residents can access the DMS in clinical routine only in 20% (n = 10/50) of the departments. An interdisciplinary dose team, which among other things communicates dose data internally (63%, n = 76/120) and externally, is already implemented in 57% (n = 68/120) departments.
CONCLUSION: Swiss radiological departments are committed to radiation safety. However, there is high heterogeneity among them regarding the frequency and method of dose data analysis as well as the use of DMS and radiation protection activities. KEY POINTS: • Swiss radiological departments are committed to and interest in radiation safety as proven by a 63% return rate of the survey. • Seventy-nine per cent of departments analyse dose data on a regular basis with differences in the frequency and method of analysis: 42% use a dose management software, while 58% currently perform manual dose data analysis. Of the latter, 43% plan to buy a dose management software. • Currently, only 25% of the departments add radiation exposure data to the final CT report.

Keywords:  Computed tomography; Patient safety; Quality improvement; Radiation protection; Surveys and questionnaires

Mesh:

Year:  2018        PMID: 29808427     DOI: 10.1007/s00330-018-5408-0

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  18 in total

1.  Image Wisely: a campaign to increase awareness about adult radiation protection.

Authors:  James A Brink; E Stephen Amis
Journal:  Radiology       Date:  2010-12       Impact factor: 11.105

2.  Radiation Doses in Consecutive CT Examinations from Five University of California Medical Centers.

Authors:  Rebecca Smith-Bindman; Michelle Moghadassi; Nicole Wilson; Thomas R Nelson; John M Boone; Christopher H Cagnon; Robert Gould; David J Hall; Mayil Krishnam; Ramit Lamba; Michael McNitt-Gray; Anthony Seibert; Diana L Miglioretti
Journal:  Radiology       Date:  2015-05-19       Impact factor: 11.105

Review 3.  Experience with patient dosimetry and quality control online for diagnostic and interventional radiology using DICOM services.

Authors:  Eliseo Vano; Jose I Ten; Jose M Fernandez-Soto; Roberto M Sanchez-Casanueva
Journal:  AJR Am J Roentgenol       Date:  2013-04       Impact factor: 3.959

4.  Modernisation and consolidation of the European radiation protection legislation: the new Euratom Basic Safety Standards Directive.

Authors:  Stefan Mundigl
Journal:  Radiat Prot Dosimetry       Date:  2014-09-16       Impact factor: 0.972

Review 5.  Dose Monitoring in Radiology Departments: Status Quo and Future Perspectives.

Authors:  J Boos; A Meineke; O T Bethge; G Antoch; P Kröpil
Journal:  Rofo       Date:  2016-04-28

6.  Transatlantic Comparison of CT Radiation Doses in the Era of Radiation Dose-Tracking Software.

Authors:  Anushri Parakh; Andre Euler; Zsolt Szucs-Farkas; Sebastian T Schindera
Journal:  AJR Am J Roentgenol       Date:  2017-09-12       Impact factor: 3.959

7.  Current CT practice in Germany: Results and implications of a nationwide survey.

Authors:  Alexander A Schegerer; Hans-Dieter Nagel; Georg Stamm; Gerhard Adam; Gunnar Brix
Journal:  Eur J Radiol       Date:  2017-02-17       Impact factor: 3.528

Review 8.  Image Gently: progress and challenges in CT education and advocacy.

Authors:  Marilyn J Goske; Kimberly E Applegate; Dorothy Bulas; Priscilla F Butler; Michael J Callahan; Brian D Coley; Steven Don; Donald P Frush; Marta Hernanz-Schulman; Sue C Kaste; Gregory Morrison; Manrita Sidhu; Keith J Strauss; S Ted Treves
Journal:  Pediatr Radiol       Date:  2011-08-17

Review 9.  Key Concepts of Patient Safety in Radiology.

Authors:  David B Larson; Jonathan B Kruskal; Karl N Krecke; Lane F Donnelly
Journal:  Radiographics       Date:  2015-09-04       Impact factor: 5.333

10.  Exposure to low dose computed tomography for lung cancer screening and risk of cancer: secondary analysis of trial data and risk-benefit analysis.

Authors:  Cristiano Rampinelli; Paolo De Marco; Daniela Origgi; Patrick Maisonneuve; Monica Casiraghi; Giulia Veronesi; Lorenzo Spaggiari; Massimo Bellomi
Journal:  BMJ       Date:  2017-02-08
View more
  1 in total

1.  Update of national diagnostic reference levels for adult CT in Switzerland and assessment of radiation dose reduction since 2010.

Authors:  Christoph Aberle; Nick Ryckx; Reto Treier; Sebastian Schindera
Journal:  Eur Radiol       Date:  2019-11-20       Impact factor: 5.315

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.