Literature DB >> 22420018

Exposure of the Swiss population by medical x-rays: 2008 review.

Eleni Theano Samara1, Abbas Aroua, François O Bochud, Barbara Ott, Thomas Theiler, Reto Treier, Philipp R Trueb, John-Paul Vader, Francis R Verdun.   

Abstract

Nationwide surveys on radiation dose to the population from medical radiology are recommended in order to follow the trends in population exposure and ensure radiation protection.The last survey in Switzerland was conducted in 1998,and the annual effective dose from medical radiology was estimated to be 1 mSv y j(-1) per capita. The purpose of this work was to follow the trends in diagnostic radiology between 1998 and 2008 in Switzerland and determine the contribution of different modalities and types of examinations to the collective effective dose from medical x-rays. For this reason, an online database(www.raddose.ch) was developed. All healthcare providers who hold a license to run an x-ray unit in the country were invited to participate in the survey. More than 225 examinations, covering eight radiological modalities, were included in the survey. The average effective dose for each examination was reassessed. Data from about 3,500 users were collected (42% response rate). The survey showed that the annual effective dose was 1.2 mSv/capita in 2008. The most frequent examinations are conventional and dental radiographies (88%). The contribution of computed tomography was only 6% in terms of examination frequency but 68% in terms of effective dose. The comparison with other countries showed that the effective dose per capita in Switzerland was in the same range as in other countries with similar healthcare systems, although the annual number of examinations performed in Switzerland was higher.

Entities:  

Mesh:

Year:  2012        PMID: 22420018     DOI: 10.1097/hp.0b013e31823513ff

Source DB:  PubMed          Journal:  Health Phys        ISSN: 0017-9078            Impact factor:   1.316


  14 in total

1.  Anthropomorphic model observer performance in three-dimensional detection task for low-contrast computed tomography.

Authors:  Alexandre Ba; Miguel P Eckstein; Damien Racine; Julien G Ott; Francis Verdun; Sabine Kobbe-Schmidt; François O Bochud
Journal:  J Med Imaging (Bellingham)       Date:  2015-12-29

2.  Computed tomography use in a large Italian region: trend analysis 2004-2014 of emergency and outpatient CT examinations in children and adults.

Authors:  Andrea Pola; Daniela Corbella; Andrea Righini; Alberto Torresin; Paola E Colombo; Luigi Vismara; Luca Trombetta; Michele Maddalo; Maria Vittoria Introini; Daniela Tinelli; Laura Strohmenger; Giovanna Garattini; Angelica Munari; Fabio Triulzi
Journal:  Eur Radiol       Date:  2018-01-09       Impact factor: 5.315

3.  X-ray population exposure from projection radiology and computed tomography in Emilia-Romagna from 2001 to 2010: comparison of ICRP 60 and ICRP 103 weighting factors.

Authors:  Gaetano Compagnone; Paola Angelini; Sara Domenichelli
Journal:  Radiol Med       Date:  2013-12-12       Impact factor: 3.469

4.  Multidetector CT radiation dose optimisation in adults: short- and long-term effects of a clinical audit.

Authors:  Denis Tack; Andreas Jahnen; Sarah Kohler; Nico Harpes; Viviane De Maertelaer; Carlo Back; Pierre Alain Gevenois
Journal:  Eur Radiol       Date:  2013-08-29       Impact factor: 5.315

5.  Computed tomography of the chest with model-based iterative reconstruction using a radiation exposure similar to chest X-ray examination: preliminary observations.

Authors:  Angeliki Neroladaki; Diomidis Botsikas; Sana Boudabbous; Christoph D Becker; Xavier Montet
Journal:  Eur Radiol       Date:  2012-08-15       Impact factor: 5.315

6.  Whole-body CT-based imaging algorithm for multiple trauma patients: radiation dose and time to diagnosis.

Authors:  S Gordic; H Alkadhi; S Hodel; H-P Simmen; M Brueesch; T Frauenfelder; G Wanner; K Sprengel
Journal:  Br J Radiol       Date:  2015-01-16       Impact factor: 3.039

7.  TLD measurements and Monte Carlo calculations of head and neck organ and effective doses for cone beam computed tomography using 3D Accuitomo 170.

Authors:  Marina Ernst; Peter Manser; Karl Dula; Werner Volken; Marco Fm Stampanoni; Michael K Fix
Journal:  Dentomaxillofac Radiol       Date:  2017-07-27       Impact factor: 2.419

8.  Update of national diagnostic reference levels for adult CT in Switzerland and assessment of radiation dose reduction since 2010.

Authors:  Christoph Aberle; Nick Ryckx; Reto Treier; Sebastian Schindera
Journal:  Eur Radiol       Date:  2019-11-20       Impact factor: 5.315

9.  Exposure of the French paediatric population to ionising radiation from diagnostic medical procedures in 2010.

Authors:  Cécile Etard; Bernard Aubert; Myriam Mezzarobba; Marie-Odile Bernier
Journal:  Pediatr Radiol       Date:  2014-07-17

10.  Comparison of the ultra-low-dose Veo algorithm with the gold standard filtered back projection for detecting pulmonary asbestos-related conditions: a clinical observational study.

Authors:  Marielle Tekath; Frédéric Dutheil; Romain Bellini; Antoine Roche; Bruno Pereira; Geraldine Naughton; Alain Chamoux; Jean-Luc Michel
Journal:  BMJ Open       Date:  2014-05-30       Impact factor: 2.692

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.