Performance comparison of two signal multiplexing readouts for SiPM-based pet detector.

Qian Yang1, Zhonghua Kuang, Ziru Sang, Yongfeng Yang, Junwei Du.   

Abstract

PET scanners using SiPMs as photodetectors could have tens of thousands of SiPMs. To simplify the readout electronics, analog signal multiplexing readouts are always preferred to be used as early as possible. In this paper, two simple analog signal multiplexing readouts, a capacitive charge-division readout, and a resistive charge-division readout were evaluated and compared using dual-ended readout detectors based on 10  ×  10 arrays of SensL MicroFJ-30035 SiPMs coupled to both ends of a 20  ×  20 LYSO array with a pitch size of 1.5 mm and a length of 20 mm. The performance of the detectors were evaluated at different bias voltages (from 27.0 V to 30.5 V with an interval of 0.5 V) and a temperature of 22.8 °C. The flood histograms show that all the crystals in the LYSO array were clearly identified, whilst better flood histogram was obtained using the resistive charge-division readout. At a bias voltage of 29.5V, the flood histogram quality, energy resolution, DOI resolution, and timing resolution of the detector obtained using the capacitive charge-division readout were 3.28  ±  0.85, 18.9%  ±  6.2%, 1.93  ±  0.20 mm, 1.25  ±  0.11 ns respectively, and those obtained using the resistive charge-division readout were 3.57  ±  0.81, 16.9%  ±  6.5%, 1.96  ±  0.23 mm and 1.23  ±  0.07 ns, respectively. Overall, the detector with the resistive charge-division readout provided better performance.

Entities:  

Mesh:

Substances:

Year:  2019        PMID: 31722318     DOI: 10.1088/1361-6560/ab5738

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  5 in total

1.  A high resolution and high detection efficiency depth-encoding detector for brain positron emission tomography based on a 0.75 mm pitch scintillator array.

Authors:  J Du; S R Cherry
Journal:  J Instrum       Date:  2021-05-20       Impact factor: 1.415

2.  Performance of Dual-Ended Readout PET Detectors Based on BGO Arrays and BaSO4 Reflector.

Authors:  Junwei Du
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2021-07-12

3.  Performance evaluation of dual-ended readout PET detectors based on BGO arrays with different reflector arrangements.

Authors:  Junwei Du; Qian Wang; Chih-Chieh Liu; Jinyi Qi; Simon R Cherry
Journal:  Phys Med Biol       Date:  2021-10-19       Impact factor: 4.174

4.  A depth-encoding PET detector for high resolution PET using 1 mm SiPMs.

Authors:  Junwei Du; Xiaowei Bai; Simon R Cherry
Journal:  Phys Med Biol       Date:  2020-08-19       Impact factor: 3.609

5.  H2RSPET: a 0.5 mm resolution high-sensitivity small-animal PET scanner, a simulation study.

Authors:  Youfang Lai; Qian Wang; Shiwei Zhou; Zhaoheng Xie; Jinyi Qi; Simon R Cherry; Mingwu Jin; Yujie Chi; Junwei Du
Journal:  Phys Med Biol       Date:  2021-03-09       Impact factor: 3.609

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.