Performance of Dual-Ended Readout PET Detectors Based on BGO Arrays and BaSO4 Reflector.

Junwei Du1.   

Abstract

In this paper, the performance of two dual-ended readout PET detectors based on 15 × 15 BGO arrays were compared. The crystal elements of one BGO array have polished lateral surfaces, while the crystal elements of the other BGO array have unpolished lateral surfaces. The two ends of the BGO elements are polished. The two BGO arrays both have a pitch size of 1.6 mm and thickness of 20 mm, and BaSO4 with a thickness of 80 μm was used as the reflector. Hamamatsu S14161-0305-08 SiPM arrays were used as photodetectors. All the measurements were performed at a bias voltage of 41.0 V and a temperature of 23.5 °C. The flood histograms show that all the crystal elements in the two BGO arrays were clearly resolved. The detector based on the BGO array with polished lateral surfaces provides an energy resolution of 16.9 ± 1.3%, timing resolution of 3.2 ± 0.2 ns, and DOI resolution of 18.4 ± 2.2 mm. In comparison, the detector based on the BGO array with unpolished lateral surfaces provides an energy resolution of 17.7 ± 2.0%, timing resolution of 3.5 ± 0.3 ns, and DOI resolution of 3.2 ± 0.2 mm.

Entities:  

Keywords:  BGO; DOI; PET

Year:  2021        PMID: 36212107      PMCID: PMC9540608          DOI: 10.1109/trpms.2021.3096534

Source DB:  PubMed          Journal:  IEEE Trans Radiat Plasma Med Sci        ISSN: 2469-7303


  29 in total

1.  Estimation of the minimum detectable activity of preclinical PET imaging systems with an analytical method.

Authors:  Qinan Bao; Arion F Chatziioannou
Journal:  Med Phys       Date:  2010-11       Impact factor: 4.071

2.  Design and evaluation of gapless curved scintillator arrays for simultaneous high-resolution and high-sensitivity brain PET.

Authors:  Junwei Du; Xiaowei Bai; Chih-Chieh Liu; Jinyi Qi; Simon R Cherry
Journal:  Phys Med Biol       Date:  2019-11-26       Impact factor: 3.609

3.  A depth-of-interaction encoding PET detector module with dual-ended readout using large-area silicon photomultiplier arrays.

Authors:  Junwei Du; Xiaowei Bai; Simon R Cherry
Journal:  Phys Med Biol       Date:  2018-12-14       Impact factor: 3.609

4.  In vivo tracking of single cells with PET.

Authors:  Guus A M S van Dongen; Ronald Boellaard; Danielle J Vugts
Journal:  Nat Biomed Eng       Date:  2020-08       Impact factor: 25.671

5.  Prismatoid light guide array for enhanced gamma ray localization in PET: a Monte Carlo simulation study of scintillation photon transport.

Authors:  Andy LaBella; Wei Zhao; Rick Lubinsky; Amir H Goldan
Journal:  Phys Med Biol       Date:  2020-05-15       Impact factor: 3.609

6.  Performance Characteristics of BGO Detectors for a Low Cost Preclinical PET Scanner.

Authors:  H Zhang; N T Vu; Q Bao; R W Silverman; B N Berry-Pusey; A Douraghy; D A Williams; F R Rannou; D B Stout; A F Chatziioannou
Journal:  IEEE Trans Nucl Sci       Date:  2010-06-01       Impact factor: 1.679

7.  Performance comparison of depth-encoding detectors based on dual-ended readout and different SiPMs for high-resolution PET applications.

Authors:  Junwei Du; Xiaowei Bai; Simon R Cherry
Journal:  Phys Med Biol       Date:  2019-08-07       Impact factor: 3.609

8.  Performance and limitations of positron emission tomography (PET) scanners for imaging very low activity sources.

Authors:  Melissa I Freedenberg; Ramsey D Badawi; Alice F Tarantal; Simon R Cherry
Journal:  Phys Med       Date:  2013-05-14       Impact factor: 2.685

Review 9.  Small animal PET: a review of what we have done and where we are going.

Authors:  Robert S Miyaoka; Adrienne L Lehnert
Journal:  Phys Med Biol       Date:  2020-12-10       Impact factor: 3.609

10.  Development and initial characterization of a high-resolution PET detector module with DOI.

Authors:  Mohan Li; Yuli Wang; Shiva Abbaszadeh
Journal:  Biomed Phys Eng Express       Date:  2020-10-14
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.