Literature DB >> 31595358

Is the position of dual-mobility cup in THA for femoral neck fractures optimal? A retrospective study.

Pierre-Alban Bouche1, Simon Corsia2, Baptiste Boukebous2, Pierre Boutroux2, Redoine Zahi2, Pascal Guillon2.   

Abstract

INTRODUCTION: Few studies have examined the relationship between the indication of total hip arthroplasty (THA) and the quality of its technical achievement. Implants mispositioning could happen more frequently while THA is performed on acute proximal femur fracture cases. The purpose of this study was to compare the frontal inclination (FTA) of double-mobility cups (DMC) in patients undergoing THA for hip osteoarthritis or fracture.
MATERIALS AND METHODS: This retrospective study included all patients undergoing THA for hip fracture or hip osteoarthritis. The surgical protocol was identical in all patients and included a systematic DMC implantation. In the postoperative period, the FTA was measured on anteroposterior pelvic radiographs and compared between groups. Malposition was defined for FTA values outside the 35°-55° range.
RESULTS: The study included 97 patients: 33 men, mean age: 78.8 years, 45 fractures. The misalignment rate was 55% after THA for fracture versus 33% for hip osteoarthritis (p = 0.02). The mean FTA value was 39° for "fracture" and 43° for "hip osteoarthritis" groups (p = 0.052). The risk for hip dislocation, surgical revision for mechanical or infectious cause was identical in both groups. DISCUSSION: Misalignment was more frequent when THA was achieved for an acute proximal femur fracture. Several explanations can be proposed: lesser bone quality, incomplete removal of upper acetabular osteophytes which can lead to excessive horizontalization of the cup and surgical procedure performed by younger surgeons in "fracture group". These misalignments don't cause more mechanical complications in the first months after surgery.

Entities:  

Keywords:  Double-mobility cup; Fracture; Osteoarthritis; Total hip prosthesis

Year:  2019        PMID: 31595358     DOI: 10.1007/s00590-019-02576-3

Source DB:  PubMed          Journal:  Eur J Orthop Surg Traumatol        ISSN: 1633-8065


  23 in total

Review 1.  Dislocation after total hip arthroplasty: implant design and orientation.

Authors:  Robert L Barrack
Journal:  J Am Acad Orthop Surg       Date:  2003 Mar-Apr       Impact factor: 3.020

2.  Monitoring surgical performance: an application to total hip replacement.

Authors:  David J Biau; Alexandre Milet; Fabrice Thévenin; Philippe Anract; Raphaël Porcher
Journal:  J Eval Clin Pract       Date:  2009-04-02       Impact factor: 2.431

3.  The difference between the radiographic and the operative angle of inclination of the acetabular component in total hip arthroplasty: use of a digital protractor and the circumference of the hip to improve orientation.

Authors:  G Meermans; I Goetheer-Smits; R F Lim; W J Van Doorn; J Kats
Journal:  Bone Joint J       Date:  2015-05       Impact factor: 5.082

4.  Modern Dual-Mobility Cups in Revision Total Hip Arthroplasty: A Systematic Review and Meta-Analysis.

Authors:  Jay M Levin; Assem A Sultan; Jeffrey A O'Donnell; Nipun Sodhi; Anton Khlopas; Nicolas S Piuzzi; Michael A Mont
Journal:  J Arthroplasty       Date:  2018-08-18       Impact factor: 4.757

5.  Anatomic referencing of cup orientation in total hip arthroplasty.

Authors:  Moritz Tannast; Ulrich Langlotz; Klaus-Arno Siebenrock; Matthias Wiese; Kai Bernsmann; Frank Langlotz
Journal:  Clin Orthop Relat Res       Date:  2005-07       Impact factor: 4.176

6.  Total hip arthroplasty using a cementless dual-mobility cup provides increased stability and favorable gait parameters at five years follow-up.

Authors:  A Acker; J-F Fischer; K Aminian; E Lécureux; B M Jolles
Journal:  Orthop Traumatol Surg Res       Date:  2016-11-24       Impact factor: 2.256

7.  A Pilot Study of Augmented Reality Technology Applied to the Acetabular Cup Placement During Total Hip Arthroplasty.

Authors:  Hiroyuki Ogawa; Seiichirou Hasegawa; Sachiyuki Tsukada; Masaaki Matsubara
Journal:  J Arthroplasty       Date:  2018-02-05       Impact factor: 4.757

8.  Do Dual-Mobility Cups Reduce the Risk of Dislocation in Total Hip Arthroplasty for Fractured Neck of Femur in Patients Aged Older Than 75 Years?

Authors:  Christophe Nich; Eric Vandenbussche; Bernard Augereau; Jérôme Sadaka
Journal:  J Arthroplasty       Date:  2015-12-02       Impact factor: 4.757

9.  Patient versus surgeon satisfaction after total hip arthroplasty.

Authors:  R B G Brokelman; C J M van Loon; W J Rijnberg
Journal:  J Bone Joint Surg Br       Date:  2003-05

Review 10.  Acetabular cup position and risk of dislocation in primary total hip arthroplasty.

Authors:  Kurt G Seagrave; Anders Troelsen; Henrik Malchau; Henrik Husted; Kirill Gromov
Journal:  Acta Orthop       Date:  2016-11-23       Impact factor: 3.717

View more
  1 in total

1.  Do Dual-mobility Cups Reduce Revision Risk in Femoral Neck Fractures Compared With Conventional THA Designs? An International Meta-analysis of Arthroplasty Registries.

Authors:  John E Farey; James Masters; Alana R Cuthbert; Pernille Iversen; Liza N van Steenbergen; Heather A Prentice; Sam Adie; Adrian Sayers; Michael R Whitehouse; Elizabeth W Paxton; Matthew L Costa; Søren Overgaard; Cecilia Rogmark; Ola Rolfson; Ian A Harris
Journal:  Clin Orthop Relat Res       Date:  2022-06-16       Impact factor: 4.755

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.