Literature DB >> 19366396

Monitoring surgical performance: an application to total hip replacement.

David J Biau1, Alexandre Milet, Fabrice Thévenin, Philippe Anract, Raphaël Porcher.   

Abstract

RATIONALE, AIMS AND
OBJECTIVES: Inadequate surgical implantation of a hip replacement may result in decreased patient satisfaction and reduced implant survival. The objective was to monitor surgical performance in hip replacement.
METHOD: The study took place at a teaching centre. All primary total hip replacements were prospectively included in the series. For each hip replacement, intraoperative technical errors, cup and stem fixation and position, and postoperative complications were recorded. If all items rated were correct, the procedure was considered as correct. The Cumulative Sums (CUSUM) test was used to monitor the performance of the centre. A 90% proportion of successful procedures was considered as adequate performance and a 75% proportion of successful procedures was deemed as inadequate performance. Meetings were conducted to discuss the results of monitoring.
RESULTS: Eighty-three total hip replacements were monitored. Overall, 28 procedures (34%) were considered inadequate. The most potent reasons for inadequate performance were cup positioning and stem fixation. The CUSUM test signalled after the second procedure that performance was inadequate. After the first meeting, despite an improvement was seen, the CUSUM test raised an alarm indicating inadequate performance. The study was stopped after the second meeting because of funding reasons before it could be demonstrated that performance had reached the desired level.
CONCLUSION: This study has demonstrated that implementing a dedicated system to monitor surgical performance in a teaching hospital improves the quality of implantation of total hip replacements. Nonetheless, the target of ninety percent of adequate primary total hip replacement could not be reached and efforts should be continued.

Entities:  

Mesh:

Year:  2009        PMID: 19366396     DOI: 10.1111/j.1365-2753.2008.01029.x

Source DB:  PubMed          Journal:  J Eval Clin Pract        ISSN: 1356-1294            Impact factor:   2.431


  8 in total

1.  Monitoring the one year postoperative infection rate after primary total hip replacement.

Authors:  David J Biau; Philippe Leclerc; Simon Marmor; Valerie Zeller; Wilfrid Graff; Luc Lhotellier; Philippe Leonard; Patrick Mamoudy
Journal:  Int Orthop       Date:  2011-12-30       Impact factor: 3.075

2.  Monitoring surgical performance: an application of industrial quality process control to anterior cruciate ligament reconstruction.

Authors:  David J Biau; Philippe Landreau; Nicolas Graveleau; Nicolas Gravelau
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-05-20       Impact factor: 4.342

3.  Comparative learning curves for early complications in anatomical and reverse shoulder arthroplasty.

Authors:  Jcs Beazley; J P Evans; N D Furness; C D Smith
Journal:  Ann R Coll Surg Engl       Date:  2018-04-25       Impact factor: 1.891

4.  [Templating and radiological outcome monitoring for elective total hip arthroplasty. Applied quality management principles for safe patient care].

Authors:  S Kirschner; C Hamann; S Handreka; K P Günther; A Hartmann
Journal:  Unfallchirurg       Date:  2011-09       Impact factor: 1.000

5.  Is the position of dual-mobility cup in THA for femoral neck fractures optimal? A retrospective study.

Authors:  Pierre-Alban Bouche; Simon Corsia; Baptiste Boukebous; Pierre Boutroux; Redoine Zahi; Pascal Guillon
Journal:  Eur J Orthop Surg Traumatol       Date:  2019-10-08

6.  Total Hip Arthroplasty by the Direct Anterior Approach Using a Neck-preserving Stem: Safety, efficacy and learning curve.

Authors:  Aditya Khemka; Omar Mograby; Sarah J Lord; Zelda Doyle; Munjed Al Muderis
Journal:  Indian J Orthop       Date:  2018 Mar-Apr       Impact factor: 1.251

Review 7.  Cup placement in primary total hip arthroplasty: how to get it right without navigation or robotics.

Authors:  Geert Meermans; George Grammatopoulos; Moritz Innmann; David Beverland
Journal:  EFORT Open Rev       Date:  2022-05-31

8.  Patient injuries in primary total hip replacement.

Authors:  Teemu Helkamaa; Eero Hirvensalo; Heini Huhtala; Ville Remes
Journal:  Acta Orthop       Date:  2016-01-25       Impact factor: 3.717