Literature DB >> 30195654

Modern Dual-Mobility Cups in Revision Total Hip Arthroplasty: A Systematic Review and Meta-Analysis.

Jay M Levin1, Assem A Sultan1, Jeffrey A O'Donnell1, Nipun Sodhi1, Anton Khlopas1, Nicolas S Piuzzi1, Michael A Mont2.   

Abstract

BACKGROUND: The purpose of this systematic review is to analyze the outcomes of dual-mobility (DM) cups in revision total hip arthroplasty (THA). Specifically, we evaluated the following: (1) all-cause and aseptic survivorship rates; (2) dislocation rates; (3) complications; and (4) clinical outcomes reported using validated health status measures.
METHODS: A comprehensive literature search included studies that reported the following: (1) re-revision rates, (2) complications, and (3) clinical outcomes following DM use in revision THA. The following exclusion criteria were used: (1) studies that did not stratify their analysis between primary and revision THA, (2) studies that utilized off-label techniques, (3) review articles, (4) case studies, (5) basic science articles, (6) non-English language reports, and (6) reports on patients who underwent surgery before 2010, in order to reflect modern DM implants use and technology. A total of 9 studies were included in our final analysis.
RESULTS: Aseptic and all-cause survivorship rates were 97.7% and 94.5%. Prevalence of dislocation was 2.2%, and 0.3% for intraprosthetic dislocation. Meta-analysis comparing DM to fixed-bearing prostheses demonstrated a significantly lower odds of dislocation in the DM cohort (odds ratio 0.24, P = .002). Complications occurred in 7.4% of revision THAs with DM cups, while infection rates totaled to 3.3% of cases. Studies comparing outcomes using Harris Hip Scores did not demonstrate a statistically significant difference in improved postoperative scores (P > .05).
CONCLUSION: DM cups have demonstrated excellent survivorship, low dislocation, and overall complication rates. Therefore, it can be considered a safe and effective option, particularly in the high-risk patients who undergo revision THA.
Copyright © 2018 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  dislocations; dual mobility; fixed bearing; meta-analysis; total hip arthroplasty

Mesh:

Year:  2018        PMID: 30195654     DOI: 10.1016/j.arth.2018.08.013

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  11 in total

1.  Is the position of dual-mobility cup in THA for femoral neck fractures optimal? A retrospective study.

Authors:  Pierre-Alban Bouche; Simon Corsia; Baptiste Boukebous; Pierre Boutroux; Redoine Zahi; Pascal Guillon
Journal:  Eur J Orthop Surg Traumatol       Date:  2019-10-08

2.  Dual-mobility versus Fixed-bearing in Primary Total Hip Arthroplasty: Outcome Comparison.

Authors:  Vivek Singh; Jeremy Loloi; William Macaulay; Matthew S Hepinstall; Ran Schwarzkopf; Vinay K Aggarwal
Journal:  Hip Pelvis       Date:  2022-06-07

3.  In Revision THA, Is the Re-revision Risk for Dislocation and Aseptic Causes Greater in Dual-mobility Constructs or Large Femoral Head Bearings? A Study from the Australian Orthopaedic Association National Joint Replacement Registry.

Authors:  Wayne Hoskins; Sophia Rainbird; Chelsea Dyer; Stephen E Graves; Roger Bingham
Journal:  Clin Orthop Relat Res       Date:  2022-01-03       Impact factor: 4.755

4.  Dual-Mobility Cup Total Hip Arthroplasty for Displaced Femoral Neck Fractures: A Retrospective Study With a Median Follow-Up of 5 Years.

Authors:  Zhenfa Zhang; Guixing Xu; Lei Cao; Wei Sun; Xianshang Zeng; Nana Xiong; Shuxin Wang; Weiguang Yu; Qilong Liu; Huanyi Lin
Journal:  Geriatr Orthop Surg Rehabil       Date:  2021-04-30

5.  Cementation of a monoblock dual mobility bearing in a newly implanted porous revision acetabular component in patients undergoing revision total hip arthroplasty.

Authors:  Jonathan A Gabor; James E Feng; Shashank Gupta; Tyler E Calkins; Craig J Della Valle; Jonathan Vigdorchik; Ran Schwarzkopf
Journal:  Arthroplast Today       Date:  2019-06-14

6.  Adverse Local Tissue Reaction due to Acetabular Corrosion in Modular Dual-Mobility Constructs.

Authors:  Kevin A Sonn; R Michael Meneghini
Journal:  Arthroplast Today       Date:  2020-12-04

7.  Risk factors and modes of failure in the modern dual mobility implant. A systematic review and meta-analysis.

Authors:  Fu-Yuan Pai; Hsuan-Hsiao Ma; Te-Feng Arthur Chou; Tsan-Wen Huang; Kuo-Chin Huang; Shang-Wen Tsai; Cheng-Fong Chen; Wei-Ming Chen
Journal:  BMC Musculoskelet Disord       Date:  2021-06-14       Impact factor: 2.362

8.  Modular Dual-Mobility Liner Malseating: A Radiographic Analysis.

Authors:  Brian P Chalmers; Jeremy Dubin; Geoffrey H Westrich
Journal:  Arthroplast Today       Date:  2020-08-27

Review 9.  Dual mobility in primary total hip arthroplasty: current concepts.

Authors:  Rory Cuthbert; James Wong; Philip Mitchell; Parag Kumar Jaiswal
Journal:  EFORT Open Rev       Date:  2019-11-08

10.  A cost-effectiveness assessment of dual-mobility bearings in revision hip arthroplasty.

Authors:  Amir Khoshbin; Fares S Haddad; Sarah Ward; S O hEireamhoin; James Wu; Leo Nherera; Amit Atrey
Journal:  Bone Joint J       Date:  2020-09       Impact factor: 5.082

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.