Literature DB >> 20094888

Diagnostic reference levels in pediatric radiology in Austria.

Jochen Billinger1, Robert Nowotny, Peter Homolka.   

Abstract

BACKGROUND: Because of the higher sensitivity to radiation in children, optimization plays an essential role in pediatric radiology. Diagnostic reference levels are a helpful tool to optimize patient dose for standard radiographic procedures.
METHODS: A nationwide survey was conducted to determine doses and variation in average dose applied to children for standard X-ray examinations. Dose values for chest, skull and abdomen X-ray procedures were determined for newborns, 1, 5, 10 and 15 year olds.
RESULTS: Third quartiles of patient doses are provided and compared to European, British and German reference values. Variation in average doses between hospitals (i.e., ratio of maximal to minimal applied average dose) for the same age and examination was found to be typically a factor of eight. Ratios of maximal to minimal applied doses to individual patients were found to be approximately a factor of six higher than variations of average doses between clinics.
CONCLUSIONS: While average patient doses indicate the use of good radiological practice in general, variance in average doses applied by different hospitals indicate that audit of dose with respect to reference values will provide guidance for optimization. Such practice should result in lowering doses for pediatric examinations.

Entities:  

Mesh:

Year:  2010        PMID: 20094888     DOI: 10.1007/s00330-009-1697-7

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  6 in total

1.  A study of the application of paediatric reference levels.

Authors:  A Montgomery; C J Martin
Journal:  Br J Radiol       Date:  2000-10       Impact factor: 3.039

2.  Reference values for diagnostic radiology: application and impact.

Authors:  Joel E Gray; Benjamin R Archer; Priscilla F Butler; Barry B Hobbs; Fred A Mettler; Robert J Pizzutiello; Beth A Schueler; Keith J Strauss; Orhan H Suleiman; Martin J Yaffe
Journal:  Radiology       Date:  2005-03-09       Impact factor: 11.105

3.  Calculation of backscatter factors for diagnostic radiology using Monte Carlo methods.

Authors:  N Petoussi-Henss; M Zankl; G Drexler; W Panzer; D Regulla
Journal:  Phys Med Biol       Date:  1998-08       Impact factor: 3.609

4.  Tissue-air ratios and scatter-air ratios for diagnostic radiology (1-4 mm Al HVL).

Authors:  R M Harrison
Journal:  Phys Med Biol       Date:  1983-01       Impact factor: 3.609

5.  The European Directive on health protection of individuals against the dangers of ionising radiation in relation to medical exposures (97/43/EURATOM).

Authors:  D Teunen
Journal:  J Radiol Prot       Date:  1998-06       Impact factor: 1.394

6.  Diagnostic reference levels for thorax X-ray examinations of paediatric patients.

Authors:  T Kiljunen; H Järvinen; S Savolainen
Journal:  Br J Radiol       Date:  2007-06       Impact factor: 3.039

  6 in total
  9 in total

1.  European Guidelines for AP/PA chest X-rays: routinely satisfiable in a paediatric radiology division?

Authors:  Sebastian Tschauner; Robert Marterer; Michael Gübitz; Peter I Kalmar; Emina Talakic; Sabine Weissensteiner; Erich Sorantin
Journal:  Eur Radiol       Date:  2015-05-24       Impact factor: 5.315

2.  Visual grading analysis of digital neonatal chest phantom X-ray images: Impact of detector type, dose and image processing on image quality.

Authors:  M H Smet; L Breysem; E Mussen; H Bosmans; N W Marshall; L Cockmartin
Journal:  Eur Radiol       Date:  2018-02-19       Impact factor: 5.315

3.  Paediatric doses during some common X-ray procedures at selected referral hospitals in Tanzania.

Authors:  W Muhogora; W Ngoye; E Byorushengo; F Lwakatare; C Kalambo
Journal:  Radiat Prot Dosimetry       Date:  2015-03-19       Impact factor: 0.972

4.  [Radiological diagnostics of pediatric lungs].

Authors:  M Beer; B Ammann
Journal:  Radiologe       Date:  2015-07       Impact factor: 0.635

5.  Consideration of diagnostic reference levels for pediatric chest X-ray examinations.

Authors:  Yasuki Asada; Takuma Ichikawa
Journal:  Radiol Phys Technol       Date:  2019-08-31

6.  Multicentre survey on patient dose in paediatric imaging and proposal for updated diagnostic reference levels for France. Part 2: plain radiography and diagnostic fluoroscopy.

Authors:  David Célier; Patrice Roch; Cécile Etard; Hubert Ducou Le Pointe; Hervé J Brisse
Journal:  Eur Radiol       Date:  2019-09-16       Impact factor: 5.315

7.  Variation of Pediatric Doses Undergoing Digital and Computed Radiography Examination in Addis Ababa, Ethiopia.

Authors:  Seife Teferi; Daniel Zewdeneh
Journal:  Ethiop J Health Sci       Date:  2020-03

8.  Optimizing imaging quality and radiation dose by the age-dependent setting of tube voltage in pediatric chest digital radiography.

Authors:  Hui Guo; Wen-Ya Liu; Xiao-Ye He; Xiao-Shan Zhou; Qun-Li Zeng; Bai-Yan Li
Journal:  Korean J Radiol       Date:  2012-12-28       Impact factor: 3.500

Review 9.  A paediatric X-ray exposure chart.

Authors:  Stephen P Knight
Journal:  J Med Radiat Sci       Date:  2014-06-09
  9 in total