| Literature DB >> 31527920 |
Hideto Sagara1,2, Tetsuju Sekiryu2, Kimihiro Imaizumi2, Hiroaki Shintake2, Urara Sugiyama2, Hiroki Maehara2.
Abstract
BACKGROUND: The application of artificial tears before performing perimetry can improve the reliability and results of perimetry in patients with glaucoma and dry eye (DE). However, the effects of ocular surface and tear film conditions on perimetry measurements and reliability have not been fully characterized.Entities:
Year: 2019 PMID: 31527920 PMCID: PMC6748565 DOI: 10.1371/journal.pone.0222467
Source DB: PubMed Journal: PLoS One ISSN: 1932-6203 Impact factor: 3.240
Comparison of parameters in patients with dry eye and normal control subjects.
| Tear condition and ocular surface parameters | Patients with dry eye | Normal control subjects | |
|---|---|---|---|
| Schirmer’s test (mm) | 4.0 (2.0–7.0[0.0–25.0]) | 14.0 (8.5–19.0[6.0–34.0]) | < .001 |
| SM value (mm) | 1.9 (1.5–2.7[1.0–5.5]) | 1.8 (1.5–2.7[1.0–7.0]) | .741 |
| Blink rate before perimetry (/min) | 15.0 (9.5–19.0[2–44]) | 14.0 (10.0–20.0[3–48]) | .969 |
| Blink rate during perimetry (/min) | 5.2 (2.6–12.2[0–39]) | 3.4 (1.4–8.2[0–36]) | .265 |
| TFBUT before perimetry (sec) | 4.0 (3.0–4.5[1–5]) | 8.0 (7.0–11.0[6–17]) | < .001 |
| TFBUT after perimetry (sec) | 4.0 (3.0–5.0[2–15]) | 8.0 (6.0–11.0[3–19]) | < .001 |
| VB score before perimetry | 1.0 (0.0–2.0[0–5]) | 0.0 (0.0–1.0[0–2]) | .046 |
| VB score after perimetry | 1.0 (0.0–3.0[0–6]) | 1.0 (0.0–2.0[0–5]) | .081 |
| DEQS | 35.0 (23.2–46.7[16.7–75.0]) | 8.3 (1.7–22.5[0.0–55.0]) | < .001 |
| Fixation loss rate (%) | 11.1 (5.0–45.6[0.0–100]) | 11.0 (2.8–42.3[0.0–100]) | .931 |
| False positive rate (%) | 1.0 (1.0–4.5[0.0–62.0]) | 2.0 (0.0–8.0[0.0–81.0]) | .363 |
| False negative rate (%) | 6.0 (0.0–11.5[0.0–40.0]) | 7.0 (0.0–12.0[0.0–26.0]) | .705 |
Values are presented as median (interquartile range [min-max]). The Mann-Whitney U test was used to assess P-values.
*P<0.05. SM, strip meniscometry
TFBUT, tear film break-up time; VB score, van Bijsterveld score; DEQS, Dry Eye-related Quality of Life score.
Comparison of blink rate and other parameters during perimetry in patients with dry eye and normal control subjects.
| Blink rate during perimetry | |||
|---|---|---|---|
| Decreased | Increased or unchanged | ||
| Group 1 | Group 2 | ||
| Schirmer’s test (mm) | 3.0 (2.0–6.5[1.0–25.0]) | 5.0 (1.8–7.0[0.0–15.0]) | 1.000 |
| SM value (mm) | 1.8 (1.5–2.2[1.0–5.0]) | 2.8 (1.7–3.6[1.5–5.5]) | .102 |
| Blink rate before perimetry (/min) | 17.0 (10.5–19.0[3–44]) | 11.0 (8.8–13.3[2–16]) | .051 |
| Blink rate during perimetry (/min) | 4.6 (1.7–7.0[0–21]) | 13.4 (11.4–16.0[2–39]) | .007 |
| TFBUT before perimetry (sec) | 4.0 (3.0–4.5[2–5]) | 2.5 (2.0–4.3[1–5]) | .218 |
| TFBUT after perimetry (sec) | 4.0 (3.0–5.0[2–15]) | 3.5 (2.8–6.3[2–9]) | .621 |
| VB score before perimetry | 1.0 (0.0–2.0[0–5]) | 1.5 (1.0–2.3[0–3]) | .198 |
| VB score after perimetry | 1.0 (0.0–3.0[0–5]) | 2.0 (1.0–3.0[0–6]) | .407 |
| DEQS | 35.0 (22.5–47.5[18.3–75.0]) | 30.0 (24.6–36.3[16.7–46.7]) | .417 |
| Fixation loss rate (%) | 13.6 (6.3–57.5[0.0–100]) | 2.2 (0.0–5.9[0.0–6.7]) | .002 |
| False positive rate (%) | 1.0 (1.0–5.5[0.0–62.0]) | 1.0 (1.8–2.5[0.0–45.0]) | .587 |
| False negative rate (%) | 6.0 (0.5–11.0[0.0–40.0]) | 4.5 (0.0–13.0[0.0–29.0]) | .788 |
| Group 3 | Group 4 | ||
| Schirmer’s test (mm) | 12.0 (8.0–21.0[6.0–34.0]) | 16.0 (10.0–19.0[7.0–21.0]) | .650 |
| SM value (mm) | 1.8 (1.4–2.6[1.0–4.5]) | 1.9 (1.7–3.6[1.5–7.0]) | .204 |
| Blink rate before perimetry (/min) | 16.0 (10.0–22.0[4–48]) | 10.0 (7.5–11.3[3–18]) | .036 |
| Blink rate during perimetry (/min) | 2.6 (0.9–5.4[0–12]) | 20.1 (11.0–30.5[4–36]) | < .001 |
| TFBUT before perimetry (sec) | 9.0 (7.0–11.5[6–17]) | 6.5 (6.0–9.0[6–11]) | .087 |
| TFBUT after perimetry (sec) | 8.0 (7.0–12.0[3–19]) | 6.5 (4.8–7.3[4–11]) | .044 |
| VB score before perimetry | 0.0 (0.0–1.0[0–2]) | 1.0 (0.0–1.3[0–2]) | .308 |
| VB score after perimetry | 1.0 (0.0–2.0[0–5]) | 1.5 (0.8–2.0[0–3]) | .378 |
| DEQS | 6.7 (1.7–18.4[0.0–55.0]) | 10.8 (3.8–25.8[0.0–41.7]) | .593 |
| Fixation loss rate (%) | 18.2 (2.8–50.2[0.0–100]) | 7.9 (4.2–10.1[0.0–93.8]) | .386 |
| False positive rate (%) | 2.0 (0.0–8.0[0.0–81.0]) | 2.5 (2.0–5.3[1.0–11.0]) | .625 |
| False negative rate (%) | 8.0 (0.0–12.0[0.0–26.0]) | 1.0 (0.0–12.0[0.0–20.0]) | .526 |
Values are presented as median (interquartile range [min-max]). The Kruskal–Wallis H test and Bonferroni correction were used to access P-values.
**P<0.0083.
Fig 1Scatter diagrams of the relationships between blink rates before and during perimetry.
(A) Data for patients with dry eye. (B) Data for normal control subjects. Group 1; eyes with decreased blink rates during perimetry in patients with dry eye; Group 2; eyes with increased or unchanged blink rates during perimetry in patients with dry eye; Group 3; eyes with decreased blink rates during perimetry in normal control subjects; Group 4; eyes with increased or unchanged blink rates during perimetry in normal control subjects.
Fig 2Scatter diagrams of the relationships between TFBUT before perimetry and TFBUT after perimetry.
(A) Data for patients with dry eye. (B) Data for normal control subjects. TFBUT, tear film break-up time.
Fig 3Scatter diagrams of the relationships between VB score before perimetry and VB score after perimetry.
(A) Data for patients with dry eye. (B) Data for normal control subjects. VB score, van Bijsterveld score.
Spearman correlation coefficients between tear conditions, ocular surface findings, and perimetry reliability parameters in patients with dry eye and normal control subjects.
| Tear condition and ocular surface parameters | Perimetry reliability parameters | ||
|---|---|---|---|
| Patients with dry eye | Fixation loss rate | False positive rate | False negative rate |
| Schirmer’s test | -.263 | .125 | .159 |
| SM value | -.221 | .015 | |
| Blink rate before perimetry | .028 | .029 | -.101 |
| Blink rate during perimetry | -.098 | -.042 | |
| TFBUT before perimetry | .258 | .120 | .265 |
| TFBUT after perimetry | .213 | .030 | .189 |
| VB score before perimetry | -.119 | -.240 | .246 |
| VB score after perimetry | -.247 | -.300 | .129 |
| DEQS | .144 | -.076 | |
| Schirmer’s test | -.111 | .154 | .226 |
| SM value | -.066 | .058 | -.087 |
| Blink rate before perimetry | -.157 | -.190 | -.272 |
| Blink rate during perimetry | -.094 | -.126 | .119 |
| TFBUT before perimetry | -.012 | .103 | -.201 |
| TFBUT after perimetry | -.123 | -.188 | -.104 |
| VB score before perimetry | -.235 | -.062 | -.236 |
| VB score after perimetry | -.226 | -.090 | -.127 |
| DEQS | -.245 | -.081 | .012 |
Statistically significant correlations (P<0.05) are shown in bold.