Literature DB >> 11583674

Comparison of detectability of visual field abnormality by frequency doubling technology in primary open-angle glaucoma and normal-tension glaucoma.

N Horikoshi1, M Osako, Y Tamura, T Okano, M Usui.   

Abstract

PURPOSE: To compare the effectiveness of frequency doubling technology (FDT) in detecting abnormalities in primary open-angle glaucoma (POAG) and in normal-tension glaucoma (NTG).
METHODS: Twenty-nine POAG patients (29 eyes) and 27 NTG patients (27 eyes) were studied. All subjects underwent testing with program C-20 of FDT with appropriate corrective lenses.
RESULTS: No significant differences were observed between the two groups in mean age, mean deviation (MD), and pattern standard deviation (PSD) measured by the Humphrey Field Analyzer (HFA). The correlation between MD values determined by HFA (x) and FDT (y) is represented by y = 0.60x - 2.7 (r = 0.78, P <.01) in the POAG group and y = 0.59x + 0.6 (r = 0.81, P <.001) in the NTG group. Although the average MD measured by FDT was significantly lower in the POAG group than in the NTG group (P <.05), no significant difference was found in average PSD between the two groups. In early glaucoma cases (MD > or = -5 dB by HFA), a larger proportion of cases in the POAG group than in the NTG group had lower significance level of MD determined by FDT than by HFA (P <.02). At many test points on the temporal periphery in the FDT, the mean sensitivity was lower in the POAG group than in the NTG group; whereas no significant differences among HFA test points were observed.
CONCLUSIONS: Frequency doubling technology detected visual field abnormalities in POAG cases more sensitively than in NTG cases. This finding indicates that the pathogenesis of My-cell damage is rather different in POAG and NTG.

Entities:  

Mesh:

Year:  2001        PMID: 11583674     DOI: 10.1016/s0021-5155(01)00371-9

Source DB:  PubMed          Journal:  Jpn J Ophthalmol        ISSN: 0021-5155            Impact factor:   2.447


  3 in total

1.  Agreement between frequency doubling perimetry and static perimetry in eyes with high tension glaucoma and normal tension glaucoma.

Authors:  S Kogure; Y Toda; D Crabb; K Kashiwagi; F W Fitzke; S Tsukahara
Journal:  Br J Ophthalmol       Date:  2003-05       Impact factor: 4.638

2.  Prediction of future scotoma on conventional automated static perimetry using frequency doubling technology perimetry.

Authors:  S Kogure; Y Toda; S Tsukahara
Journal:  Br J Ophthalmol       Date:  2006-03       Impact factor: 4.638

3.  Impact of tear metrics on the reliability of perimetry in patients with dry eye.

Authors:  Hideto Sagara; Tetsuju Sekiryu; Kimihiro Imaizumi; Hiroaki Shintake; Urara Sugiyama; Hiroki Maehara
Journal:  PLoS One       Date:  2019-09-17       Impact factor: 3.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.