Literature DB >> 10715400

Usefulness of gaze tracking during perimetry in glaucomatous eyes

.   

Abstract

Purpose: To evaluate the usefulness of a new fixation monitoring system called gaze tracking in the perimetry of glaucomatous eyes. Subjects and Method: We studied the visual field of 106 eyes in 106 persons, comprising 74 eyes with open-angle glaucoma and 32 eyes with ocular hypertension. Perimetry was performed using a Humphrey Visual Field Analyzer 740/750 with a 30-2 full threshold program. We used two parameters for gaze tracking: the percentage of the time when the subject's eye deviated from the fixation target more than 3 degrees (G 3) and 6 degrees (G 6). These parameters were assessed in three groups: those with no visual field defect (group N), those with absolute visual field defect including the blind spot (group M 1), and others (group M 0).Result: The values of G 3 and G 6 were significantly correlated with the fixation loss in groups N and M 0 (P <.01). These values were not significantly correlated with the fixation loss in group M 1 (P.10). When the fixation loss was less than 20%, G 3 and G 6 values were significantly higher in group M 1 than in groups N or M 0.
Conclusion: Gaze tracking is a useful fixation monitoring system particularly in the presence absolute visual field defect including the blind spot.

Entities:  

Year:  2000        PMID: 10715400     DOI: 10.1016/s0021-5155(99)00209-9

Source DB:  PubMed          Journal:  Jpn J Ophthalmol        ISSN: 0021-5155            Impact factor:   2.447


  4 in total

Review 1.  Detection of visual field progression in glaucoma with standard achromatic perimetry: a review and practical implications.

Authors:  Kouros Nouri-Mahdavi; Nariman Nassiri; Annette Giangiacomo; Joseph Caprioli
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2011-08-26       Impact factor: 3.117

2.  Gaze tracker parameters have little association with visual field metrics of intrasession frontloaded SITA-Faster 24-2 visual field results.

Authors:  Jack Phu; Michael Kalloniatis
Journal:  Ophthalmic Physiol Opt       Date:  2022-05-22       Impact factor: 3.992

3.  Comparison of size modulation and conventional standard automated perimetry with the 24-2 test protocol in glaucoma patients.

Authors:  Kazunori Hirasawa; Nobuyuki Shoji; Masayuki Kasahara; Kazuhiro Matsumura; Kimiya Shimizu
Journal:  Sci Rep       Date:  2016-05-05       Impact factor: 4.379

4.  Impact of tear metrics on the reliability of perimetry in patients with dry eye.

Authors:  Hideto Sagara; Tetsuju Sekiryu; Kimihiro Imaizumi; Hiroaki Shintake; Urara Sugiyama; Hiroki Maehara
Journal:  PLoS One       Date:  2019-09-17       Impact factor: 3.240

  4 in total