Literature DB >> 21447676

Blink frequency and duration during perimetry and their relationship to test-retest threshold variability.

Yanfang Wang1, Sonia S Toor, Ramesh Gautam, David B Henson.   

Abstract

PURPOSE: To describe different patterns of blinking in patients undergoing a visual field test and to establish whether the blink parameters are related to threshold variability.
METHODS: Thirty-nine patients with diagnosed or suspected glaucoma were recruited to undertake a perimetric task twice. Blinks were detected with a video eye-tracker system that records at a sampling rate of 60 Hz. Blink frequency, duration, and episodes of microsleep (eye closures >500 ms) were analyzed, and correlated with test-retest threshold variability. The timing of blinks with respect to stimulus presentation was analyzed and the percentage of seen stimuli for all presentations (POS(overall)) and those overlapped with blinks (POS(overlapped)) were compared.
RESULTS: Blink frequency ranged from 0 to 58 per minute. A significant increase in blink frequency was observed in the second test (P < 0.001), whereas blink duration and microsleep episodes were not significantly different between the two tests. The relationship between test-retest threshold variability and all blink parameters was not significant. For suprathreshold stimulus presentations, blinks often occurred after presentation, whereas for subthreshold presentations, their timing was independent of stimulus timing. The difference between POS(overall) and POS(overlapped) was significant (P < 0.001), and a slight decrease in POS(overlapped) was observed with the increase of overlap duration.
CONCLUSIONS: A wide range of blink frequencies was observed during perimetric testing. Although no blink parameters showed significant influence on threshold variability, when the blinks overlapped with a stimulus presentation, the probability of seeing was reduced. For suprathreshold stimuli, blinks often occurred after the presentation, whereas for subthreshold presentations, there was no relationship to presentation time.

Entities:  

Mesh:

Year:  2011        PMID: 21447676     DOI: 10.1167/iovs.10-6553

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  11 in total

1.  Humans quickly learn to blink strategically in response to environmental task demands.

Authors:  David Hoppe; Stefan Helfmann; Constantin A Rothkopf
Journal:  Proc Natl Acad Sci U S A       Date:  2018-02-14       Impact factor: 11.205

2.  Dry Eye Symptom Severity and Visual Field Reliability Metrics.

Authors:  Andrew S Camp; Christopher P Long; Anat Galor; Maya Yamane; James A Proudfoot; Robert N Weinreb
Journal:  J Glaucoma       Date:  2022-03-18       Impact factor: 2.290

3.  Assessing Visual Fields in Patients with Retinitis Pigmentosa Using a Novel Microperimeter with Eye Tracking: The MP-3.

Authors:  Nozomi Igarashi; Masato Matsuura; Yohei Hashimoto; Kazunori Hirasawa; Hiroshi Murata; Tatsuya Inoue; Obata Ryo; Makoto Aihara; Ryo Asaoka
Journal:  PLoS One       Date:  2016-11-28       Impact factor: 3.240

4.  Pupil dilation reflects the authenticity of received nonverbal vocalizations.

Authors:  Gonçalo Cosme; Pedro J Rosa; César F Lima; Vânia Tavares; Sophie Scott; Sinead Chen; Thomas D W Wilcockson; Trevor J Crawford; Diana Prata
Journal:  Sci Rep       Date:  2021-02-12       Impact factor: 4.379

5.  The structure-function relationship measured with optical coherence tomography and a microperimeter with auto-tracking: the MP-3, in patients with retinitis pigmentosa.

Authors:  Yuichi Asahina; Marie Kitano; Yohei Hashimoto; Mieko Yanagisawa; Hiroshi Murata; Tatsuya Inoue; Ryo Obata; Ryo Asaoka
Journal:  Sci Rep       Date:  2017-11-17       Impact factor: 4.379

6.  The Human Touch: Using a Webcam to Autonomously Monitor Compliance During Visual Field Assessments.

Authors:  Pete R Jones; Giorgia Demaria; Iris Tigchelaar; Daniel S Asfaw; David F Edgar; Peter Campbell; Tamsin Callaghan; David P Crabb
Journal:  Transl Vis Sci Technol       Date:  2020-07-20       Impact factor: 3.283

7.  Crowdsourced Measurement of Reaction Times to Audiovisual Stimuli With Various Degrees of Asynchrony.

Authors:  Pavlo Bazilinskyy; Joost de Winter
Journal:  Hum Factors       Date:  2018-07-23       Impact factor: 2.888

8.  The buildup of an urge in obsessive-compulsive disorder: Behavioral and neuroimaging correlates.

Authors:  Emily R Stern; Carina Brown; Molly Ludlow; Rebbia Shahab; Katherine Collins; Alexis Lieval; Russell H Tobe; Dan V Iosifescu; Katherine E Burdick; Lazar Fleysher
Journal:  Hum Brain Mapp       Date:  2020-01-09       Impact factor: 5.399

9.  Impact of tear metrics on the reliability of perimetry in patients with dry eye.

Authors:  Hideto Sagara; Tetsuju Sekiryu; Kimihiro Imaizumi; Hiroaki Shintake; Urara Sugiyama; Hiroki Maehara
Journal:  PLoS One       Date:  2019-09-17       Impact factor: 3.240

10.  Direct comparison of retinal structure and function in retinitis pigmentosa by co-registering microperimetry and optical coherence tomography.

Authors:  Jun Funatsu; Yusuke Murakami; Shunji Nakatake; Masato Akiyama; Kohta Fujiwara; Shotaro Shimokawa; Takashi Tachibana; Toshio Hisatomi; Yoshito Koyanagi; Yukihide Momozawa; Koh-Hei Sonoda; Yasuhiro Ikeda
Journal:  PLoS One       Date:  2019-12-12       Impact factor: 3.240