Literature DB >> 31342349

Mg-Al-CO3 layered double hydroxide reinforced polymer inclusion membrane as an extractant phase for thin-film microextraction of cyanide from environmental water samples.

Maliheh Heidarbeigi1, Mohammad Saraji2, Mohammad Taghi Jafari1.   

Abstract

In this paper, a flexible and efficient nano-reinforced polymer inclusion membrane (PIM) was fabricated and used for cyanide (CN-) extraction from water samples. Aliquat 336 (a liquid anion exchanger) was embedded in poly(vinyl chloride) (PVC) support as the extractant. Mg-Al-CO3 layered double hydroxide (LDH) with high surface area and anion exchange ability was applied to promote the extraction efficiency of PIM. A PIM comprising 56% PVC, 40% Aliquat 336, and 4% Mg-Al-CO3 LDH showed the best extraction efficiency. A single beam ultraviolet-visible spectrophotometer was used for the detection of cyanide. Surface morphology of the PIM was studied by field emission scanning electron microscopy. The experimental parameters influencing the extraction process were investigated and optimized. The intra- and inter-day relative standard deviations at two different concentrations were in the range of 2.8-7.6%. The dynamic range of the method was in the range of 5-500 μg L-1, and the detection limit was 1.4 μg L-1. The LDH reinforced PIM showed proper characteristics for the extraction of cyanide from real water and wastewater samples with recoveries between 82 and 115%.

Entities:  

Keywords:  Aliquat 336; Cyanide; Layered double hydroxide; Nano-reinforced; Polymer inclusion membrane; UV-vis spectroscopy

Mesh:

Substances:

Year:  2019        PMID: 31342349     DOI: 10.1007/s11356-019-06000-5

Source DB:  PubMed          Journal:  Environ Sci Pollut Res Int        ISSN: 0944-1344            Impact factor:   4.223


  19 in total

Review 1.  New developments in microextraction techniques in bioanalysis. A review.

Authors:  Juan Antonio Ocaña-González; Rut Fernández-Torres; Miguel Ángel Bello-López; María Ramos-Payán
Journal:  Anal Chim Acta       Date:  2015-11-10       Impact factor: 6.558

2.  An improved method for cyanide determination in blood using solid-phase microextraction and gas chromatography/mass spectrometry.

Authors:  Giampietro Frison; Flavio Zancanaro; Donata Favretto; Santo Davide Ferrara
Journal:  Rapid Commun Mass Spectrom       Date:  2006       Impact factor: 2.419

Review 3.  Microextraction techniques combined with capillary electrophoresis in bioanalysis.

Authors:  Isabelle Kohler; Julie Schappler; Serge Rudaz
Journal:  Anal Bioanal Chem       Date:  2012-09-11       Impact factor: 4.142

4.  Simultaneous determination of cyanide and thiocyanate in plasma by chemical ionization gas chromatography mass-spectrometry (CI-GC-MS).

Authors:  Raj K Bhandari; Robert P Oda; Stephanie L Youso; Ilona Petrikovics; Vikhyat S Bebarta; Gary A Rockwood; Brian A Logue
Journal:  Anal Bioanal Chem       Date:  2012-09-04       Impact factor: 4.142

5.  A novel polymer inclusion membrane based method for continuous clean-up of thiocyanate from gold mine tailings water.

Authors:  Youngsoo Cho; Robert W Cattrall; Spas D Kolev
Journal:  J Hazard Mater       Date:  2017-08-02       Impact factor: 10.588

6.  The use of a polymer inclusion membrane as a sorbent for online preconcentration in the flow injection determination of thiocyanate impurity in ammonium sulfate fertilizer.

Authors:  Takumi Ohshima; Shigehiro Kagaya; Makoto Gemmei-Ide; Robert W Cattrall; Spas D Kolev
Journal:  Talanta       Date:  2014-06-20       Impact factor: 6.057

7.  Dissolvable layered double hydroxide coated magnetic nanoparticles for extraction followed by high performance liquid chromatography for the determination of phenolic acids in fruit juices.

Authors:  Mohammad Saraji; Milad Ghani
Journal:  J Chromatogr A       Date:  2014-09-18       Impact factor: 4.759

8.  Headspace sorptive solid phase microextraction (HS-SPME) combined with a spectrophotometry system: A simple glass devise for extraction and simultaneous determination of cyanide and thiocyanate in environmental and biological samples.

Authors:  H M Al-Saidi; Sami A Al-Harbi; E H Aljuhani; M S El-Shahawi
Journal:  Talanta       Date:  2016-06-07       Impact factor: 6.057

9.  Headspace single-drop microextraction and cuvetteless microspectrophotometry for the selective determination of free and total cyanide involving reaction with ninhydrin.

Authors:  Archana Jain; Aradhana K K V Pillai; Nisha Sharma; Krishna K Verma
Journal:  Talanta       Date:  2010-05-27       Impact factor: 6.057

10.  Ultratrace determination of total and available cyanides in industrial wastewaters through a rapid headspace-based sample preparation and gas chromatography with nitrogen phosphorous detection analysis.

Authors:  Daniele Marton; Andrea Tapparo; Valerio B Di Marco; Carla Repice; Chiara Giorio; Sara Bogialli
Journal:  J Chromatogr A       Date:  2013-03-13       Impact factor: 4.759

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.