Literature DB >> 27474290

Headspace sorptive solid phase microextraction (HS-SPME) combined with a spectrophotometry system: A simple glass devise for extraction and simultaneous determination of cyanide and thiocyanate in environmental and biological samples.

H M Al-Saidi1, Sami A Al-Harbi1, E H Aljuhani2, M S El-Shahawi3.   

Abstract

A simple, low cost and efficient headspace sorptive solid phase microextraction (HS-SPME) method for determination of cyanide has been developed. The system comprises of a glass tube with two valves and a moveable glass slide fixed at its centre. It includes an acceptor phase polyurethane foam treated mercury (II) dithizonate [Hg(HDz)2-PUF] complex fixed inside by a septum cap in a cylindrical configuration (5.0cm length and 1.0cm diameter). The extraction is based upon the contact of the acceptor phase to the headspace and subsequently measuring the absorbance of the recovered mercury (II) dithizonate from PUFs sorbent. Unlike other HSSE, extraction and back - extractions was carried out in a closed system, thereby improving the analytical performance by preventing the analyte loss. Under the optimized conditions, a linear calibration plot in the range of 1.0-50.0µmolL(-1) was achieved with limits of detection (LOD) and quantification (LOQ) of 0.34, 1.2µmolL(-1) CN(-), respectively. Simultaneous analysis of cyanide and thiocyanate in saliva was also performed with satisfactory recoveries.
Copyright © 2016. Published by Elsevier B.V.

Entities:  

Keywords:  Headspace sportive extraction; Saliva; Simultaneous determination of cyanide and thiocyanate; Wastewater

Mesh:

Substances:

Year:  2016        PMID: 27474290     DOI: 10.1016/j.talanta.2016.06.019

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  2 in total

1.  Mg-Al-CO3 layered double hydroxide reinforced polymer inclusion membrane as an extractant phase for thin-film microextraction of cyanide from environmental water samples.

Authors:  Maliheh Heidarbeigi; Mohammad Saraji; Mohammad Taghi Jafari
Journal:  Environ Sci Pollut Res Int       Date:  2019-07-24       Impact factor: 4.223

2.  Development of an Analytical Protocol for Determination of Cyanide in Human Biological Samples Based on Application of Ion Chromatography with Pulsed Amperometric Detection.

Authors:  Ewa Jaszczak; Marek Ruman; Sylwia Narkowicz; Jacek Namieśnik; Żaneta Polkowska
Journal:  J Anal Methods Chem       Date:  2017-11-21       Impact factor: 2.193

  2 in total