Literature DB >> 16941546

An improved method for cyanide determination in blood using solid-phase microextraction and gas chromatography/mass spectrometry.

Giampietro Frison1, Flavio Zancanaro, Donata Favretto, Santo Davide Ferrara.   

Abstract

A new method is described for the qualitative and quantitative analysis of cyanide, a very short-acting and powerful toxic agent, in human whole blood. It involves the conversion of cyanide into hydrogen cyanide and its subsequent headspace solid-phase microextraction (HS-SPME) and detection by gas chromatography/mass spectrometry (GC/MS) in selected ion monitoring (SIM) mode. Optimizing the conditions for the GC/MS (type of column, injection conditions, temperature program) and SPME (choice of SPME fiber, effect of salts, adsorption and desorption times, adsorption temperature) led to the choice of a 75-microm carboxen/polydimethylsiloxane SPME fiber, with D3-acetonitrile as internal standard, and a capillary GC column with a polar stationary phase. Method validation was carried out in terms of linearity, precision and accuracy in both aqueous solutions and blood. The limit of detection (LOD) and limit of quantitation (LOQ) were determined only in aqueous solutions. The assay is linear over three orders of magnitude (water 0.01-10, blood 0.05-10 microg/mL); and the LOD and LOQ in water were 0.006 and 0.01 microg/mL, respectively. Good intra- and inter-assay precision was obtained, always <8%. The method is simple, fast and sensitive enough for the rapid diagnosis of cyanide intoxication in clinical and forensic toxicology. Copyright 2006 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16941546     DOI: 10.1002/rcm.2689

Source DB:  PubMed          Journal:  Rapid Commun Mass Spectrom        ISSN: 0951-4198            Impact factor:   2.419


  4 in total

Review 1.  Recent developments in cyanide detection: a review.

Authors:  Jian Ma; Purnendu K Dasgupta
Journal:  Anal Chim Acta       Date:  2010-06-04       Impact factor: 6.558

2.  Mg-Al-CO3 layered double hydroxide reinforced polymer inclusion membrane as an extractant phase for thin-film microextraction of cyanide from environmental water samples.

Authors:  Maliheh Heidarbeigi; Mohammad Saraji; Mohammad Taghi Jafari
Journal:  Environ Sci Pollut Res Int       Date:  2019-07-24       Impact factor: 4.223

3.  A disposable blood cyanide sensor.

Authors:  Yong Tian; Purnendu K Dasgupta; Sari B Mahon; Jian Ma; Matthew Brenner; Jian-Hua Wang; Gerry R Boss
Journal:  Anal Chim Acta       Date:  2013-02-01       Impact factor: 6.558

4.  Diagnosis of cyanide poisoning using an automated, field-portable sensor for rapid analysis of blood cyanide concentrations.

Authors:  Nesta Bortey-Sam; Randy Jackson; Obed A Gyamfi; Subrata Bhadra; Caleb Freeman; Sari B Mahon; Matthew Brenner; Gary A Rockwood; Brian A Logue
Journal:  Anal Chim Acta       Date:  2019-11-15       Impact factor: 6.558

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.