Headspace single-drop microextraction and cuvetteless microspectrophotometry for the selective determination of free and total cyanide involving reaction with ninhydrin.

Archana Jain1, Aradhana K K V Pillai, Nisha Sharma, Krishna K Verma.   

Abstract

Headspace single-drop microextraction has been used for the determination of cyanide with ninhydrin in combination with fibre-optic-based cuvetteless microspectrophotometry which accommodates sample volume of 1 microL placed between the two ends of optical fibres, and has been found to avoid salient drawbacks of batch methods. This method involved hydrocyanic acid formation in a closed vial, and simultaneous extraction and reaction with 2 microL drop of ninhydrin in carbonate medium suspended at the tip of a microsyringe needle held in the headspace of the acidified sample solution. The method was linear in range 0.025-0.5 mg L(-1) of cyanide. The headspace reaction was free from the interference of substances, e.g., thiocyanate, hydrazine sulphate, hydroxylammonium chloride and ascorbic acid. Sulphide was masked by cadmium sulphate, nitrite by sulphamic acid, sulphite by N-ethylmaleimide, and halogens by ascorbic acid. The limit of detection was found to be 4.3 microg L(-1) of cyanide which was comparable to existing most sensitive methods for cyanide. However, the present method is far more simple. The method was applied to acid-labile and metal cyanides complexes by treatment with sulphide when metal sulphides were precipitated setting cyanide ion free, and to iron(II) and (III) cyanide complexes by their decomposition with mercury(II), the mercury(II) cyanide formed was then determined. These pre-treatment methods avoided cumbersome pre-separation of cyanide by methods such as distillation or gas diffusion. The overall recovery of cyanide in diverse samples was 97% with RSD of 3.9%. Copyright 2010 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20602966     DOI: 10.1016/j.talanta.2010.05.048

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  3 in total

1.  Mg-Al-CO3 layered double hydroxide reinforced polymer inclusion membrane as an extractant phase for thin-film microextraction of cyanide from environmental water samples.

Authors:  Maliheh Heidarbeigi; Mohammad Saraji; Mohammad Taghi Jafari
Journal:  Environ Sci Pollut Res Int       Date:  2019-07-24       Impact factor: 4.223

2.  Sensitive determination of terazosin in pharmaceutical formulations and biological samples by ionic-liquid microextraction prior to spectrofluorimetry.

Authors:  Mohsen Zeeb; Mahdi Sadeghi
Journal:  Int J Anal Chem       Date:  2012-02-08       Impact factor: 1.885

3.  Determination of cyanide in bamboo shoots by microdiffusion combined with ion chromatography-pulsed amperometric detection.

Authors:  Ming Ding; Kailiang Wang
Journal:  R Soc Open Sci       Date:  2018-04-18       Impact factor: 2.963

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.