Literature DB >> 25127633

The use of a polymer inclusion membrane as a sorbent for online preconcentration in the flow injection determination of thiocyanate impurity in ammonium sulfate fertilizer.

Takumi Ohshima1, Shigehiro Kagaya2, Makoto Gemmei-Ide1, Robert W Cattrall3, Spas D Kolev4.   

Abstract

A polymer inclusion membrane (PIM) is used for the first time as a sorbent in the construction of a preconcentration column to enhance the sensitivity in flow injection analysis (FIA). The PIM-coated column is readily prepared by coating the PIM containing poly(vinyl chloride), Aliquat 336, and 1-tetradecanol onto glass beads packed in a glass tube. The determination of trace amounts of thiocyanate in ammonium sulfate fertilizer demonstrates the potential of the proposed PIM-coated column in FIA. Thiocyanate standards or samples of relatively large volume (e.g. up to 2000 µL) are injected into a nitrate carrier stream. The sample zone passes through the proposed preconcentration column where thiocyanate is concentrated in a smaller volume of a carrier solution thus resulting in up to 7.4 fold increase in sensitivity. Thiocyanate is detected spectrophotometrically after its reaction with Fe(III) downstream of the preconcentration column. The limits of detection of thiocyanate in the absence and presence of 20 g L(-1) ammonium sulfate (S/N=2) are 0.014 and 0.024 mg L(-1), respectively. Thiocyanate was successfully determined in several samples of ammonium sulfate fertilizer.
Copyright © 2014 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Ammonium sulfate fertilizer; Flow injection analysis; Polymer inclusion membrane (PIM); Preconcentration column; Solid-phase extraction; Thiocyanate

Year:  2014        PMID: 25127633     DOI: 10.1016/j.talanta.2014.06.029

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  4 in total

1.  FIA-coupled spectrophotometric method for determination of Cr (VI) traces in natural waters: application of in-line dissolution of 1,5-diphenylcarbazide after heat treatment and activated alumina as adsorbent for preconcentration.

Authors:  Diogenes Meneses; José Guimarães F Júnior; Paulo Cesar Costa de Oliveira
Journal:  Environ Monit Assess       Date:  2018-09-28       Impact factor: 2.513

2.  Mg-Al-CO3 layered double hydroxide reinforced polymer inclusion membrane as an extractant phase for thin-film microextraction of cyanide from environmental water samples.

Authors:  Maliheh Heidarbeigi; Mohammad Saraji; Mohammad Taghi Jafari
Journal:  Environ Sci Pollut Res Int       Date:  2019-07-24       Impact factor: 4.223

3.  How to identify a smoker: a salient crystallographic approach to detect thiocyanate content.

Authors:  Khushboo Iman; M Naqi Ahamad; Azaj Ansari; Hatem A M Saleh; M Shahnawaz Khan; Musheer Ahmad; Rosenani A Haque; M Shahid
Journal:  RSC Adv       Date:  2021-05-07       Impact factor: 4.036

4.  Determination of Cadmium (II) in Aqueous Solutions by In Situ MID-FTIR-PLS Analysis Using a Polymer Inclusion Membrane-Based Sensor: First Considerations.

Authors:  René González-Albarrán; Josefina de Gyves; Eduardo Rodríguez de San Miguel
Journal:  Molecules       Date:  2020-07-29       Impact factor: 4.411

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.