Literature DB >> 31318989

Automatic large quantity landmark pairs detection in 4DCT lung images.

Yabo Fu1, Xue Wu1, Allan M Thomas1, Harold H Li1, Deshan Yang1.   

Abstract

PURPOSE: To automatically and precisely detect a large quantity of landmark pairs between two lung computed tomography (CT) images to support evaluation of deformable image registration (DIR). We expect that the generated landmark pairs will significantly augment the current lung CT benchmark datasets in both quantity and positional accuracy.
METHODS: A large number of landmark pairs were detected within the lung between the end-exhalation (EE) and end-inhalation (EI) phases of the lung four-dimensional computed tomography (4DCT) datasets. Thousands of landmarks were detected by applying the Harris-Stephens corner detection algorithm on the probability maps of the lung vasculature tree. A parametric image registration method (pTVreg) was used to establish initial landmark correspondence by registering the images at EE and EI phases. A multi-stream pseudo-siamese (MSPS) network was then developed to further improve the landmark pair positional accuracy by directly predicting three-dimensional (3D) shifts to optimally align the landmarks in EE to their counterparts in EI. Positional accuracies of the detected landmark pairs were evaluated using both digital phantoms and publicly available landmark pairs.
RESULTS: Dense sets of landmark pairs were detected for 10 4DCT lung datasets, with an average of 1886 landmark pairs per case. The mean and standard deviation of target registration error (TRE) were 0.47 ± 0.45 mm with 98% of landmark pairs having a TRE smaller than 2 mm for 10 digital phantom cases. Tests using 300 manually labeled landmark pairs in 10 lung 4DCT benchmark datasets (DIRLAB) produced TRE results of 0.73 ± 0.53 mm with 97% of landmark pairs having a TRE smaller than 2 mm.
CONCLUSION: A new method was developed to automatically and precisely detect a large quantity of landmark pairs between lung CT image pairs. The detected landmark pairs could be used as benchmark datasets for more accurate and informative quantitative evaluation of DIR algorithms.
© 2019 American Association of Physicists in Medicine.

Keywords:  Deformable image registration; medical image processing

Mesh:

Year:  2019        PMID: 31318989      PMCID: PMC8311742          DOI: 10.1002/mp.13726

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  38 in total

1.  Semi-automatic construction of reference standards for evaluation of image registration.

Authors:  K Murphy; B van Ginneken; S Klein; M Staring; B J de Hoop; M A Viergever; J P W Pluim
Journal:  Med Image Anal       Date:  2010-08-03       Impact factor: 8.545

2.  Characterization of deformation and physical force in uniform low contrast anatomy and its impact on accuracy of deformable image registration.

Authors:  Raj Varadhan; Taiki Magome; Susanta Hui
Journal:  Med Phys       Date:  2016-01       Impact factor: 4.071

3.  Auto-propagation of contours for adaptive prostate radiation therapy.

Authors:  Ming Chao; Yaoqin Xie; Lei Xing
Journal:  Phys Med Biol       Date:  2008-08-01       Impact factor: 3.609

4.  A framework for evaluation of deformable image registration spatial accuracy using large landmark point sets.

Authors:  Richard Castillo; Edward Castillo; Rudy Guerra; Valen E Johnson; Travis McPhail; Amit K Garg; Thomas Guerrero
Journal:  Phys Med Biol       Date:  2009-03-05       Impact factor: 3.609

5.  Use of image registration and fusion algorithms and techniques in radiotherapy: Report of the AAPM Radiation Therapy Committee Task Group No. 132.

Authors:  Kristy K Brock; Sasa Mutic; Todd R McNutt; Hua Li; Marc L Kessler
Journal:  Med Phys       Date:  2017-05-23       Impact factor: 4.071

6.  Deformable image registration for adaptive radiation therapy of head and neck cancer: accuracy and precision in the presence of tumor changes.

Authors:  Angelo Mencarelli; Simon Robert van Kranen; Olga Hamming-Vrieze; Suzanne van Beek; Coenraad Robert Nico Rasch; Marcel van Herk; Jan-Jakob Sonke
Journal:  Int J Radiat Oncol Biol Phys       Date:  2014-08-20       Impact factor: 7.038

7.  An adaptive motion regularization technique to support sliding motion in deformable image registration.

Authors:  Yabo Fu; Shi Liu; H Harold Li; Hua Li; Deshan Yang
Journal:  Med Phys       Date:  2018-01-12       Impact factor: 4.071

8.  An automatic contour propagation method to follow parotid gland deformation during head-and-neck cancer tomotherapy.

Authors:  E Faggiano; C Fiorino; E Scalco; S Broggi; M Cattaneo; E Maggiulli; I Dell'Oca; N Di Muzio; R Calandrino; G Rizzo
Journal:  Phys Med Biol       Date:  2011-01-14       Impact factor: 3.609

9.  Reconstruction of 4D-CT from a single free-breathing 3D-CT by spatial-temporal image registration.

Authors:  Guorong Wu; Qian Wang; Jun Lian; Dinggang Shen
Journal:  Inf Process Med Imaging       Date:  2011

10.  Does atlas-based autosegmentation of neck levels require subsequent manual contour editing to avoid risk of severe target underdosage? A dosimetric analysis.

Authors:  Peter W J Voet; Maarten L P Dirkx; David N Teguh; Mischa S Hoogeman; Peter C Levendag; Ben J M Heijmen
Journal:  Radiother Oncol       Date:  2011-01-25       Impact factor: 6.280

View more
  3 in total

1.  LungRegNet: An unsupervised deformable image registration method for 4D-CT lung.

Authors:  Yabo Fu; Yang Lei; Tonghe Wang; Kristin Higgins; Jeffrey D Bradley; Walter J Curran; Tian Liu; Xiaofeng Yang
Journal:  Med Phys       Date:  2020-02-26       Impact factor: 4.071

2.  Detection of vessel bifurcations in CT scans for automatic objective assessment of deformable image registration accuracy.

Authors:  Guillaume Cazoulat; Brian M Anderson; Molly M McCulloch; Bastien Rigaud; Eugene J Koay; Kristy K Brock
Journal:  Med Phys       Date:  2021-08-25       Impact factor: 4.506

3.  GroupRegNet: a groupwise one-shot deep learning-based 4D image registration method.

Authors:  Yunlu Zhang; Xue Wu; H Michael Gach; Harold Li; Deshan Yang
Journal:  Phys Med Biol       Date:  2021-02-12       Impact factor: 3.609

  3 in total