Literature DB >> 32017141

LungRegNet: An unsupervised deformable image registration method for 4D-CT lung.

Yabo Fu1, Yang Lei1, Tonghe Wang1, Kristin Higgins1, Jeffrey D Bradley1, Walter J Curran1, Tian Liu1, Xiaofeng Yang1.   

Abstract

PURPOSE: To develop an accurate and fast deformable image registration (DIR) method for four-dimensional computed tomography (4D-CT) lung images. Deep learning-based methods have the potential to quickly predict the deformation vector field (DVF) in a few forward predictions. We have developed an unsupervised deep learning method for 4D-CT lung DIR with excellent performances in terms of registration accuracies, robustness, and computational speed.
METHODS: A fast and accurate 4D-CT lung DIR method, namely LungRegNet, was proposed using deep learning. LungRegNet consists of two subnetworks which are CoarseNet and FineNet. As the name suggests, CoarseNet predicts large lung motion on a coarse scale image while FineNet predicts local lung motion on a fine scale image. Both the CoarseNet and FineNet include a generator and a discriminator. The generator was trained to directly predict the DVF to deform the moving image. The discriminator was trained to distinguish the deformed images from the original images. CoarseNet was first trained to deform the moving images. The deformed images were then used by the FineNet for FineNet training. To increase the registration accuracy of the LungRegNet, we generated vessel-enhanced images by generating pulmonary vasculature probability maps prior to the network prediction.
RESULTS: We performed fivefold cross validation on ten 4D-CT datasets from our department. To compare with other methods, we also tested our method using separate 10 DIRLAB datasets that provide 300 manual landmark pairs per case for target registration error (TRE) calculation. Our results suggested that LungRegNet has achieved better registration accuracy in terms of TRE than other deep learning-based methods available in the literature on DIRLAB datasets. Compared to conventional DIR methods, LungRegNet could generate comparable registration accuracy with TRE smaller than 2 mm. The integration of both the discriminator and pulmonary vessel enhancements into the network was crucial to obtain high registration accuracy for 4D-CT lung DIR. The mean and standard deviation of TRE were 1.00 ± 0.53 mm and 1.59 ± 1.58 mm on our datasets and DIRLAB datasets respectively.
CONCLUSIONS: An unsupervised deep learning-based method has been developed to rapidly and accurately register 4D-CT lung images. LungRegNet has outperformed its deep-learning-based peers and achieved excellent registration accuracy in terms of TRE.
© 2020 American Association of Physicists in Medicine.

Entities:  

Keywords:  4D-CT lung; deep learning; deformable image registration; unsupervised learning

Mesh:

Year:  2020        PMID: 32017141      PMCID: PMC7165051          DOI: 10.1002/mp.14065

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  42 in total

1.  Adversarial learning for mono- or multi-modal registration.

Authors:  Jingfan Fan; Xiaohuan Cao; Qian Wang; Pew-Thian Yap; Dinggang Shen
Journal:  Med Image Anal       Date:  2019-08-24       Impact factor: 8.545

2.  Estimation of slipping organ motion by registration with direction-dependent regularization.

Authors:  Alexander Schmidt-Richberg; René Werner; Heinz Handels; Jan Ehrhardt
Journal:  Med Image Anal       Date:  2011-06-26       Impact factor: 8.545

3.  Pulmonary CT Registration Through Supervised Learning With Convolutional Neural Networks.

Authors:  Koen A J Eppenhof; Josien P W Pluim
Journal:  IEEE Trans Med Imaging       Date:  2018-10-26       Impact factor: 10.048

4.  Nonrigid Image Registration Using Spatially Region-Weighted Correlation Ratio and GPU-Acceleration.

Authors:  Lun Gong; Cheng Zhang; Luwen Duan; Xueying Du; Hanqiu Liu; Xinjian Chen; Jian Zheng
Journal:  IEEE J Biomed Health Inform       Date:  2018-05-15       Impact factor: 5.772

5.  Paired cycle-GAN-based image correction for quantitative cone-beam computed tomography.

Authors:  Joseph Harms; Yang Lei; Tonghe Wang; Rongxiao Zhang; Jun Zhou; Xiangyang Tang; Walter J Curran; Tian Liu; Xiaofeng Yang
Journal:  Med Phys       Date:  2019-07-17       Impact factor: 4.071

6.  Automated segmentation of a motion mask to preserve sliding motion in deformable registration of thoracic CT.

Authors:  Jef Vandemeulebroucke; Olivier Bernard; Simon Rit; Jan Kybic; Patrick Clarysse; David Sarrut
Journal:  Med Phys       Date:  2012-02       Impact factor: 4.071

7.  Four-dimensional deformable image registration using trajectory modeling.

Authors:  Edward Castillo; Richard Castillo; Josue Martinez; Maithili Shenoy; Thomas Guerrero
Journal:  Phys Med Biol       Date:  2010-01-07       Impact factor: 3.609

8.  A multi-scale framework with unsupervised joint training of convolutional neural networks for pulmonary deformable image registration.

Authors:  Zhuoran Jiang; Fang-Fang Yin; Yun Ge; Lei Ren
Journal:  Phys Med Biol       Date:  2020-01-13       Impact factor: 3.609

9.  Deep learning-based attenuation correction in the absence of structural information for whole-body positron emission tomography imaging.

Authors:  Xue Dong; Yang Lei; Tonghe Wang; Kristin Higgins; Tian Liu; Walter J Curran; Hui Mao; Jonathon A Nye; Xiaofeng Yang
Journal:  Phys Med Biol       Date:  2020-03-02       Impact factor: 3.609

10.  Comparison of internal target volumes defined on 3-dimensional, 4-dimensonal, and cone-beam CT images of non-small-cell lung cancer.

Authors:  Fengxiang Li; Jianbin Li; Zhifang Ma; Yingjie Zhang; Jun Xing; Huanpeng Qi; Dongping Shang
Journal:  Onco Targets Ther       Date:  2016-11-17       Impact factor: 4.147

View more
  10 in total

1.  Few-shot learning for deformable image registration in 4DCT images.

Authors:  Weicheng Chi; Zhiming Xiang; Fen Guo
Journal:  Br J Radiol       Date:  2021-10-18       Impact factor: 3.039

2.  Artificial Intelligence in Radiation Therapy.

Authors:  Yabo Fu; Hao Zhang; Eric D Morris; Carri K Glide-Hurst; Suraj Pai; Alberto Traverso; Leonard Wee; Ibrahim Hadzic; Per-Ivar Lønne; Chenyang Shen; Tian Liu; Xiaofeng Yang
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2021-08-24

3.  Real-time MRI motion estimation through an unsupervised k-space-driven deformable registration network (KS-RegNet).

Authors:  Hua-Chieh Shao; Tian Li; Michael J Dohopolski; Jing Wang; Jing Cai; Jun Tan; Kai Wang; You Zhang
Journal:  Phys Med Biol       Date:  2022-06-29       Impact factor: 4.174

Review 4.  A review of deep learning based methods for medical image multi-organ segmentation.

Authors:  Yabo Fu; Yang Lei; Tonghe Wang; Walter J Curran; Tian Liu; Xiaofeng Yang
Journal:  Phys Med       Date:  2021-05-13       Impact factor: 2.685

5.  GroupRegNet: a groupwise one-shot deep learning-based 4D image registration method.

Authors:  Yunlu Zhang; Xue Wu; H Michael Gach; Harold Li; Deshan Yang
Journal:  Phys Med Biol       Date:  2021-02-12       Impact factor: 3.609

6.  An unsupervised 2D-3D deformable registration network (2D3D-RegNet) for cone-beam CT estimation.

Authors:  You Zhang
Journal:  Phys Med Biol       Date:  2021-03-24       Impact factor: 4.174

Review 7.  Deep learning in structural and functional lung image analysis.

Authors:  Joshua R Astley; Jim M Wild; Bilal A Tahir
Journal:  Br J Radiol       Date:  2021-04-20       Impact factor: 3.629

8.  Bendlet Transform Based Adaptive Denoising Method for Microsection Images.

Authors:  Shuli Mei; Meng Liu; Aleksey Kudreyko; Piercarlo Cattani; Denis Baikov; Francesco Villecco
Journal:  Entropy (Basel)       Date:  2022-06-24       Impact factor: 2.738

Review 9.  Machine learning applications in radiation oncology.

Authors:  Matthew Field; Nicholas Hardcastle; Michael Jameson; Noel Aherne; Lois Holloway
Journal:  Phys Imaging Radiat Oncol       Date:  2021-06-24

10.  A pilot study: Quantify lung volume and emphysema extent directly from two-dimensional scout images.

Authors:  Jiantao Pu; Jacob Sechrist; Xin Meng; Joseph K Leader; Frank C Sciurba
Journal:  Med Phys       Date:  2021-07-06       Impact factor: 4.506

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.