Literature DB >> 20709592

Semi-automatic construction of reference standards for evaluation of image registration.

K Murphy1, B van Ginneken, S Klein, M Staring, B J de Hoop, M A Viergever, J P W Pluim.   

Abstract

Quantitative evaluation of image registration algorithms is a difficult and under-addressed issue due to the lack of a reference standard in most registration problems. In this work a method is presented whereby detailed reference standard data may be constructed in an efficient semi-automatic fashion. A well-distributed set of n landmarks is detected fully automatically in one scan of a pair to be registered. Using a custom-designed interface, observers define corresponding anatomic locations in the second scan for a specified subset of s of these landmarks. The remaining n-s landmarks are matched fully automatically by a thin-plate-spline based system using the s manual landmark correspondences to model the relationship between the scans. The method is applied to 47 pairs of temporal thoracic CT scans, three pairs of brain MR scans and five thoracic CT datasets with synthetic deformations. Interobserver differences are used to demonstrate the accuracy of the matched points. The utility of the reference standard data as a tool in evaluating registration is shown by the comparison of six sets of registration results on the 47 pairs of thoracic CT data.
Copyright © 2010 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20709592     DOI: 10.1016/j.media.2010.07.005

Source DB:  PubMed          Journal:  Med Image Anal        ISSN: 1361-8415            Impact factor:   8.545


  25 in total

Review 1.  Deformable medical image registration: a survey.

Authors:  Aristeidis Sotiras; Christos Davatzikos; Nikos Paragios
Journal:  IEEE Trans Med Imaging       Date:  2013-05-31       Impact factor: 10.048

2.  A fast deformable registration method for 4D lung CT in hybrid framework.

Authors:  Wei Xia; Xin Gao
Journal:  Int J Comput Assist Radiol Surg       Date:  2013-11-22       Impact factor: 2.924

3.  Comparison of breathing gated CT images generated using a 5DCT technique and a commercial clinical protocol in a porcine model.

Authors:  Dylan P O'Connell; David H Thomas; Tai H Dou; James M Lamb; Franklin Feingold; Daniel A Low; Matthew K Fuld; Jered P Sieren; Chelsea M Sloan; Melissa A Shirk; Eric A Hoffman; Christian Hofmann
Journal:  Med Phys       Date:  2015-07       Impact factor: 4.071

4.  Registration of vascular structures using a hybrid mixture model.

Authors:  Siming Bayer; Zhiwei Zhai; Maddalena Strumia; Xiaoguang Tong; Ying Gao; Marius Staring; Berend Stoel; Rebecca Fahrig; Arya Nabavi; Andreas Maier; Nishant Ravikumar
Journal:  Int J Comput Assist Radiol Surg       Date:  2019-06-07       Impact factor: 2.924

5.  Automatic large quantity landmark pairs detection in 4DCT lung images.

Authors:  Yabo Fu; Xue Wu; Allan M Thomas; Harold H Li; Deshan Yang
Journal:  Med Phys       Date:  2019-08-07       Impact factor: 4.071

6.  Effect of deformable registration on the dose calculated in radiation therapy planning CT scans of lung cancer patients.

Authors:  Alexandra R Cunliffe; Clay Contee; Samuel G Armato; Bradley White; Julia Justusson; Renuka Malik; Hania A Al-Hallaq
Journal:  Med Phys       Date:  2015-01       Impact factor: 4.071

7.  Deformable registration of the inflated and deflated lung in cone-beam CT-guided thoracic surgery: initial investigation of a combined model- and image-driven approach.

Authors:  Ali Uneri; Sajendra Nithiananthan; Sebastian Schafer; Yoshito Otake; J Webster Stayman; Gerhard Kleinszig; Marc S Sussman; Jerry L Prince; Jeffrey H Siewerdsen
Journal:  Med Phys       Date:  2013-01       Impact factor: 4.071

8.  Reproducibility of registration-based measures of lung tissue expansion.

Authors:  Kaifang Du; John E Bayouth; Kunlin Cao; Gary E Christensen; Kai Ding; Joseph M Reinhardt
Journal:  Med Phys       Date:  2012-03       Impact factor: 4.071

9.  Comparison of Two Deformable Registration Algorithms in the Presence of Radiologic Change Between Serial Lung CT Scans.

Authors:  Alexandra R Cunliffe; Bradley White; Julia Justusson; Christopher Straus; Renuka Malik; Hania A Al-Hallaq; Samuel G Armato
Journal:  J Digit Imaging       Date:  2015-12       Impact factor: 4.056

10.  Image registration for quantitative parametric response mapping of cancer treatment response.

Authors:  Jennifer L Boes; Benjamin A Hoff; Nola Hylton; Martin D Pickles; Lindsay W Turnbull; Anne F Schott; Alnawaz Rehemtulla; Ryan Chamberlain; Benjamin Lemasson; Thomas L Chenevert; Craig J Galbán; Charles R Meyer; Brian D Ross
Journal:  Transl Oncol       Date:  2014-02-01       Impact factor: 4.243

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.