Characterization of deformation and physical force in uniform low contrast anatomy and its impact on accuracy of deformable image registration.

Raj Varadhan1, Taiki Magome2, Susanta Hui2.   

Abstract

PURPOSE: Little is known about the effect of force on organ deformation and consequently its impact on precision dose delivery. The purpose of this study was to evaluate the fundamental relationship between anatomic deformation and its causative physical force to ascertain if a threshold limit exists for deformable image registration (DIR) accuracy in uniform low contrast anatomy, beyond which its applicability may be clinically inappropriate.
METHODS: To simulate a simplified model, a tissue equivalent deformable bladder phantom with 21 implanted fiducial markers was developed using a viscoelastic polymer. The bladder phantom was deformed by applying a force in increments from 10 to 70 N. DIR accuracy was studied using intensity based mim and Velocity B-spline algorithms by comparing the 3D vector of the 21 marker locations at the original target image with the synthetically derived marker positions from each target image obtained from DIR.
RESULTS: The relationship between applied force in 1D deformation along the axis of applied force and 3D deformation of the phantom showed a linear response. The maximum and average displacements of markers exhibited a nonlinear response to the applied force. In the absence of implanted markers, DIR performance was suboptimal with a threshold limit of only 20 N (5 mm deformation) beyond which the average marker error was ≥3 mm. DIR performance improved significantly with the addition of only one marker for the intensity based mim algorithm. In contrast, the Velocity B-spline algorithm showed reduced sensitivity to the number of markers introduced in both the source and target images.
CONCLUSIONS: The limits of applicability of DIR are strongly dependent on the magnitude of deformation. There is a threshold limit beyond which the accuracy of DIR fails in uniform low contrast anatomy. The sensitivity of the DIR performance to the number of fiducial markers present indicates that if DIR performance is solely assessed with the contrast rich features present in clinical anatomy, the results may not be reflective of the true DIR performance in uniform low contrast anatomy.

Mesh:

Year:  2016        PMID: 26745899      PMCID: PMC4684569          DOI: 10.1118/1.4937935

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  34 in total

1.  PET-CT image registration in the chest using free-form deformations.

Authors:  David Mattes; David R Haynor; Hubert Vesselle; Thomas K Lewellen; William Eubank
Journal:  IEEE Trans Med Imaging       Date:  2003-01       Impact factor: 10.048

2.  Medical virtual reality. The current status of the future.

Authors:  R M Satava
Journal:  Stud Health Technol Inform       Date:  1996

3.  Modelling liver tissue properties using a non-linear visco-elastic model for surgery simulation.

Authors:  Jean-Marc Schwartz; Marc Denninger; Denis Rancourt; Christian Moisan; Denis Laurendeau
Journal:  Med Image Anal       Date:  2004-12-02       Impact factor: 8.545

4.  Deformable registration of the planning image (kVCT) and the daily images (MVCT) for adaptive radiation therapy.

Authors:  Weiguo Lu; Gustavo H Olivera; Quan Chen; Kenneth J Ruchala; Jason Haimerl; Sanford L Meeks; Katja M Langen; Patrick A Kupelian
Journal:  Phys Med Biol       Date:  2006-08-15       Impact factor: 3.609

5.  Biomechanical properties of abdominal organs in vivo and postmortem under compression loads.

Authors:  Jacob Rosen; Jeffrey D Brown; Smita De; Mika Sinanan; Blake Hannaford
Journal:  J Biomech Eng       Date:  2008-04       Impact factor: 2.097

6.  Passive properties of the urinary bladder in the collection phase.

Authors:  R van Mastrigt; B L Coolsaet; W A van Duyl
Journal:  Med Biol Eng Comput       Date:  1978-09       Impact factor: 2.602

7.  A graphics-based software system to develop and analyze models of musculoskeletal structures.

Authors:  S L Delp; J P Loan
Journal:  Comput Biol Med       Date:  1995-01       Impact factor: 4.589

8.  Medical applications of virtual reality.

Authors:  R M Satava
Journal:  J Med Syst       Date:  1995-06       Impact factor: 4.460

9.  Composition and biomechanical properties of the bladder acellular matrix graft: comparative analysis in rat, pig and human.

Authors:  S E Dahms; H J Piechota; R Dahiya; T F Lue; E A Tanagho
Journal:  Br J Urol       Date:  1998-09

10.  Constitutive modeling of rate-dependent stress-strain behavior of human liver in blunt impact loading.

Authors:  Jessica L Sparks; Rebecca B Dupaix
Journal:  Ann Biomed Eng       Date:  2008-08-27       Impact factor: 3.934

View more
  4 in total

1.  Automatic large quantity landmark pairs detection in 4DCT lung images.

Authors:  Yabo Fu; Xue Wu; Allan M Thomas; Harold H Li; Deshan Yang
Journal:  Med Phys       Date:  2019-08-07       Impact factor: 4.071

2.  Implementing Radiation Dose-Volume Liver Response in Biomechanical Deformable Image Registration.

Authors:  Daniel F Polan; Mary Feng; Theodore S Lawrence; Randall K Ten Haken; Kristy K Brock
Journal:  Int J Radiat Oncol Biol Phys       Date:  2017-06-27       Impact factor: 7.038

3.  Evaluation of Varian's SmartAdapt for clinical use in radiation therapy for patients with thoracic lesions.

Authors:  Jason Vickress; Maria Alejandra Rangel Baltazar; Hossein Afsharpour
Journal:  J Appl Clin Med Phys       Date:  2021-02-11       Impact factor: 2.102

4.  Autosegmentation of the rectum on megavoltage image guidance scans.

Authors:  L E A Shelley; M P F Sutcliffe; K Harrison; J E Scaife; M A Parker; M Romanchikova; S J Thomas; R Jena; N G Burnet
Journal:  Biomed Phys Eng Express       Date:  2019-01-10
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.