Literature DB >> 21761696

Reconstruction of 4D-CT from a single free-breathing 3D-CT by spatial-temporal image registration.

Guorong Wu1, Qian Wang, Jun Lian, Dinggang Shen.   

Abstract

In the radiation therapy of lung cancer, a free-breathing 3D-CT image is usually acquired in the treatment day for image-guided patient setup, by registering with the free-breathing 3D-CT image acquired in the planning day. In this way, the optimal dose plan computed in the planning day can be transferred onto the treatment day for cancer radiotherapy. However, patient setup based on the simple registration of the free-breathing 3D-CT images of the planning and the treatment days may mislead the radiotherapy, since the free-breathing 3D-CT is actually the mixed-phase image, with different slices often acquired from different respiratory phases. Moreover, a 4D-CT that is generally acquired in the planning day for improvement of dose planning is often ignored for guiding patient setup in the treatment day. To overcome these limitations, we present a novel two-step method to reconstruct the 4D-CT from a single free-breathing 3D-CT of the treatment day, by utilizing the 4D-CT model built in the planning day. Specifically, in the first step, we proposed a new spatial-temporal registration algorithm to align all phase images of the 4D-CT acquired in the planning day, for building a 4D-CT model with temporal correspondences established among all respiratory phases. In the second step, we first determine the optimal phase for each slice of the free-breathing (mixed-phase) 3D-CT of the treatment day by comparing with the 4D-CT of the planning day and thus obtain a sequence of partial 3D-CT images for the treatment day, each with only the incomplete image information in certain slices; and then we reconstruct a complete 4D-CT for the treatment day by warping the 4D-CT of the planning day (with complete information) to the sequence of partial 3D-CT images of the treatment day, under the guidance of the 4D-CT model built in the planning day. We have comprehensively evaluated our 4D-CT model building algorithm on a public lung image database, achieving the best registration accuracy over all other state-of-the-art methods. Also, we have validated our proposed 4D-CT reconstruction algorithm on the simulated free-breathing data, obtaining very promising 4D-CT reconstruction results.

Entities:  

Mesh:

Year:  2011        PMID: 21761696      PMCID: PMC3141594          DOI: 10.1007/978-3-642-22092-0_56

Source DB:  PubMed          Journal:  Inf Process Med Imaging        ISSN: 1011-2499


  9 in total

1.  Artifacts in computed tomography scanning of moving objects.

Authors:  George T Y Chen; Jong H Kung; Kevin P Beaudette
Journal:  Semin Radiat Oncol       Date:  2004-01       Impact factor: 5.934

2.  Acquiring a four-dimensional computed tomography dataset using an external respiratory signal.

Authors:  S S Vedam; P J Keall; V R Kini; H Mostafavi; H P Shukla; R Mohan
Journal:  Phys Med Biol       Date:  2003-01-07       Impact factor: 3.609

3.  Unsupervised learning of an atlas from unlabeled point-sets.

Authors:  Haili Chui; Anand Rangarajan; Jie Zhang; Christiana Morison Leonard
Journal:  IEEE Trans Pattern Anal Mach Intell       Date:  2004-02       Impact factor: 6.226

4.  Nonrigid registration of dynamic medical imaging data using nD + t B-splines and a groupwise optimization approach.

Authors:  C T Metz; S Klein; M Schaap; T van Walsum; W J Niessen
Journal:  Med Image Anal       Date:  2010-10-28       Impact factor: 8.545

5.  A comparison of algorithms for inference and learning in probabilistic graphical models.

Authors:  Brendan J Frey; Nebojsa Jojic
Journal:  IEEE Trans Pattern Anal Mach Intell       Date:  2005-09       Impact factor: 6.226

6.  Tracking lung tissue motion and expansion/compression with inverse consistent image registration and spirometry.

Authors:  Gary E Christensen; Joo Hyun Song; Wei Lu; Issam El Naqa; Daniel A Low
Journal:  Med Phys       Date:  2007-06       Impact factor: 4.071

7.  Diffeomorphic demons: efficient non-parametric image registration.

Authors:  Tom Vercauteren; Xavier Pennec; Aymeric Perchant; Nicholas Ayache
Journal:  Neuroimage       Date:  2008-11-07       Impact factor: 6.556

8.  A framework for evaluation of deformable image registration spatial accuracy using large landmark point sets.

Authors:  Richard Castillo; Edward Castillo; Rudy Guerra; Valen E Johnson; Travis McPhail; Amit K Garg; Thomas Guerrero
Journal:  Phys Med Biol       Date:  2009-03-05       Impact factor: 3.609

9.  Automated lung segmentation for thoracic CT impact on computer-aided diagnosis.

Authors:  Samuel G Armato; William F Sensakovic
Journal:  Acad Radiol       Date:  2004-09       Impact factor: 3.173

  9 in total
  4 in total

1.  Automatic large quantity landmark pairs detection in 4DCT lung images.

Authors:  Yabo Fu; Xue Wu; Allan M Thomas; Harold H Li; Deshan Yang
Journal:  Med Phys       Date:  2019-08-07       Impact factor: 4.071

2.  4D-CT Lung registration using anatomy-based multi-level multi-resolution optical flow analysis and thin-plate splines.

Authors:  Yugang Min; John Neylon; Amish Shah; Sanford Meeks; Percy Lee; Patrick Kupelian; Anand P Santhanam
Journal:  Int J Comput Assist Radiol Surg       Date:  2014-01-14       Impact factor: 2.924

3.  Temporal Subtraction of Serial CT Images with Large Deformation Diffeomorphic Metric Mapping in the Identification of Bone Metastases.

Authors:  Ryo Sakamoto; Masahiro Yakami; Koji Fujimoto; Keita Nakagomi; Takeshi Kubo; Yutaka Emoto; Thai Akasaka; Gakuto Aoyama; Hiroyuki Yamamoto; Michael I Miller; Susumu Mori; Kaori Togashi
Journal:  Radiology       Date:  2017-07-03       Impact factor: 11.105

Review 4.  Lung deposition analyses of inhaled toxic aerosols in conventional and less harmful cigarette smoke: a review.

Authors:  Clement Kleinstreuer; Yu Feng
Journal:  Int J Environ Res Public Health       Date:  2013-09-23       Impact factor: 3.390

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.